Development and Evaluation of a Duplex Real-Time PCR Assay With a Novel Internal Standard for Precise Quantification of Plasma DNA

被引:6
作者
Chen, Dan [1 ,2 ]
Pan, Shiyang [1 ,2 ]
Xie, Erfu [1 ,2 ]
Gao, Li [1 ,2 ]
Xu, Huaguo [1 ,2 ]
Xia, Wenying [1 ,2 ]
Xu, Ting [1 ,2 ]
Huang, Peijun [1 ,2 ]
机构
[1] Nanjing Med Univ, Affiliated Hosp 1, Dept Lab Med, 300 Guangzhou Rd, Nanjing 210029, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Affiliated Hosp 1, Natl Key Clin Dept Lab Med, Nanjing, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Plasma DNA; Duplex PCR; Quantification; Internal standard; Reference interval; Trauma; CELL-FREE DNA; LUNG-CANCER; CIRCULATING DNA; NUCLEIC-ACIDS; SERUM; ELECTROPHORESIS; SYSTEM;
D O I
10.3343/alm.2017.37.1.18
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Circulating levels of cell-free DNA increase in many pathologic conditions. However, notable discrepancies in the quantitative analysis of cell-free DNA from a large number of laboratories have become a considerable pitfall, hampering its clinical application. Methods: We designed a novel recombinant DNA fragment that could be applied as an internal standard in a newly developed and validated duplex real-time PCR assay for the quantitative analysis of total cell-free plasma DNA, which was tested in 5,442 healthy adults and 200 trauma patients. Results: Compared with two traditional methods, this novel assay showed a lower detection limit of 0.1 ng/mL, lower intra- and inter-assay CVs, and higher accuracy in the recovery test. The median plasma DNA concentration of healthy males (20.3 ng/mL, n=3,092) was significantly higher than that of healthy females (16.1 ng/mL, n=2,350) (Mann-Whitney two-sample rank sum test, P<0.0001). The reference intervals of plasma DNA concentration were 0-45.8 ng/mL and 0-52.5 ng/mL for healthy females and males, respectively. The plasma DNA concentrations of the majority of trauma patients (96%) were higher than the upper normal cutoff values and were closely related to the corresponding injury severity scores (R-2=0.916, P<0.0001). Conclusions: This duplex real-time PCR assay with a new internal standard could eliminate variation and allow for more sensitive, repeatable, accurate, and stable quantitative measurements of plasma DNA, showing promising application in clinical diagnosis.
引用
收藏
页码:18 / 27
页数:10
相关论文
共 37 条
[31]  
Szpechcinski A, 2008, J PHYSIOL PHARMACOL, V59, P675
[32]   Circulating free DNA concentration is an independent prognostic biomarker in lung cancer [J].
Tissot, Claire ;
Toffart, Anne-Claire ;
Villar, Stephanie ;
Souquet, Pierre-Jean ;
Merle, Patrick ;
Moro-Sibilot, Denis ;
Perol, Maurice ;
Zavadil, Jiri ;
Brambilla, Christian ;
Olivier, Magali ;
Couraud, Sebastien .
EUROPEAN RESPIRATORY JOURNAL, 2015, 46 (06) :1773-1780
[33]   Diagnostic developments involving cell-free (circulating) nucleic acids [J].
Tong, YK ;
Lo, YMD .
CLINICA CHIMICA ACTA, 2006, 363 (1-2) :187-196
[34]   REAL-TIME DETECTION AND QUANTIFICATION OF DNA HYBRIDIZATION BY AN OPTICAL BIOSENSOR [J].
WATTS, HJ ;
YEUNG, D ;
PARKES, H .
ANALYTICAL CHEMISTRY, 1995, 67 (23) :4283-4289
[35]   Cell-free DNA: measurement in various carcinomas and establishment of normal reference range [J].
Wu, TL ;
Zhang, D ;
Chia, JH ;
Tsao, KC ;
Sun, CF ;
Wu, JT .
CLINICA CHIMICA ACTA, 2002, 321 (1-2) :77-87
[36]   Optimizing the yield and utility of circulating cell-free DNA from plasma and serum [J].
Xue, Xiaoyan ;
Teare, M. Dawn ;
Holen, Ingunn ;
Zhu, Yong M. ;
Woll, Penella J. .
CLINICA CHIMICA ACTA, 2009, 404 (02) :100-104
[37]   A new quantitative method for circulating DNA level in human serum by capillary zone electrophoresis with laser-induced fluorescence detection [J].
Zhang, P ;
Ren, JC ;
Shen, ZJ .
ELECTROPHORESIS, 2004, 25 (12) :1823-1828