Step back from the patient: Reduction of radiation dose to the operator by the systematic use of an automatic power injector for contrast media in an interventional angiography suite

被引:5
作者
Larsen, Anne Sofie F. [1 ]
Osteras, Bjorn Helge [2 ,3 ]
机构
[1] Oslo Univ Hosp, Dept Radiol, Ostfold Hosp Trust, Oslo, Norway
[2] Oslo Univ Hosp, Intervent Ctr, Oslo, Norway
[3] Univ Oslo, Fac Div Clin Med, Oslo, Norway
关键词
Vascular; angiography; occupational/environmental hazards; radiation safety; arteries; angioplasty; EXPOSURE; RADIOLOGY; DOSIMETER; PERFORMANCE; PERSONNEL; RISK;
D O I
10.1258/ar.2011.110560
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: During arterial interventional procedures, power injectors allow the operator to step back from the patient or exit the angiography suite during digital subtraction angiography (DSA) acquisitions. Increasing the distance to the radiation source reduces exposure to the operator and staff. Purpose: To systematically investigate the effect of increasing the distance between the radiation source and the operator during DSA acquisitions in a daily clinical setting, regarding radiation exposure to the operator and patient, as well as the duration of the procedure using a power injector to deliver contrast media. Material and Methods: Patients scheduled for arterial interventional procedures in the pelvis or lower extremities were consecutively included. In phase one (duration 6 weeks, 44 patients) contrast media were injected manually. In phase two (duration until the total dose area product [DAP] was equal to phase 1, 41 patients) the operator used a power injector and exited the suite whenever possible. Patient, procedure, and examination data were recorded. Collective dose to the operator's collar, lead apron, and hands was recorded using thermo luminescent dosimetry (TLD). Results: Our results showed a dose reduction of 50% to the operator's hands, lead apron, and thyroid collar when using a power injector during DSA, with no significant increase in DAP or procedure time when performing pelvic procedures. For lower extremity procedures there was a small but significant increase in procedure time and DAP. Pelvic procedures yielded substantially higher DAP than lower extremity procedures during both phases. Conclusion: Utilization of a power injector, thus allowing the operator to step back from the patient, facilitates a radiation dose reduction to the operator of approximately 50% with no significant increase in patient dose or procedure time during pelvic procedures.
引用
收藏
页码:330 / 334
页数:5
相关论文
共 19 条
[1]  
[Anonymous], 2007, ANN ICRP, V37, P1, DOI 10.1016/j.icrp.2007.11.001
[2]   Management of pediatric radiation dose using GE fluoroscopic equipment [J].
Belanger, Barry ;
Boudry, John .
PEDIATRIC RADIOLOGY, 2006, 36 (Suppl 2) :204-211
[3]   Simultaneous determination of equivalent dose to organs and tissues of the patient and of the physician in interventional radiology using the Monte Carlo method [J].
Bozkurt, A. ;
Bor, D. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (02) :317-330
[4]   Radiation safety considerations for diagnostic radiology personnel [J].
Brateman, L .
RADIOGRAPHICS, 1999, 19 (04) :1037-1055
[5]   Cancer risks attributable to low doses of ionizing radiation: Assessing what we really know [J].
Brenner, DJ ;
Doll, R ;
Goodhead, DT ;
Hall, EJ ;
Land, CE ;
Little, JB ;
Lubin, JH ;
Preston, DL ;
Preston, RJ ;
Puskin, JS ;
Ron, E ;
Sachs, RK ;
Samet, JM ;
Setlow, RB ;
Zaider, M .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (24) :13761-13766
[6]   Redundant Protective Barriers: Minimizing Operator Occupational Risk [J].
Challa, Karthik ;
Warren, Stafford G. ;
Danak, Subhash ;
Bates, Mark C. .
JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2009, 22 (03) :299-307
[7]   Radiation exposure of medical staff from interventional x-ray procedures: a multicentre study [J].
Haeusler, Uwe ;
Czarwinski, Renate ;
Brix, Gunnar .
EUROPEAN RADIOLOGY, 2009, 19 (08) :2000-2008
[8]   Radiation exposure to interventional radiologists during manual-injection digital subtraction angiography [J].
Hayashi, N ;
Sakai, T ;
Kitagawa, M ;
Inagaki, R ;
Yamamoto, F ;
Fukushima, T ;
Ishii, Y .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 21 (03) :240-243
[9]   Minimising radiation exposure to physicians performing fluoroscopically guided cardiac catheterisation procedures: a review [J].
Kim, Kwang Pyo ;
Miller, Donald L. .
RADIATION PROTECTION DOSIMETRY, 2009, 133 (04) :227-233
[10]   Occupational Health Hazards in the Interventional Laboratory: Time for a Safer Environment (Reprinted from J Vasc Interv Radiol vol 20, pg 147-152, 2009) [J].
Klein, Lloyd W. ;
Miller, Donald L. ;
Balter, Stephen ;
Laskey, Warren ;
Haines, David ;
Norbash, Alexander ;
Mauro, Matthew A. ;
Goldstein, James A. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 20 (07) :S278-S283