Hemodynamic assessment of aortic stenosis - Are there still lessons to learn?

被引:15
作者
Baumgartner, H [1 ]
机构
[1] Med Univ Vienna, Vienna Gen Hosp, Dept Cardiol, A-1090 Vienna, Austria
关键词
D O I
10.1016/j.jacc.2005.10.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:138 / 140
页数:3
相关论文
共 14 条
  • [1] DETERMINATION OF AORTIC-VALVE AREA BY DOPPLER ECHOCARDIOGRAPHY USING THE CONTINUITY EQUATION - A CRITICAL-EVALUATION
    BAUMGARTNER, H
    KRATZER, H
    HELMREICH, G
    KUEHN, P
    [J]. CARDIOLOGY, 1990, 77 (02) : 101 - 111
  • [2] Overestimation of catheter gradients by Doppler ultrasound in patients with aortic stenosis: A predictable manifestation of pressure recovery
    Baumgartner, H
    Stefenelli, T
    Niederberger, J
    Schima, H
    Maurer, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (06) : 1655 - 1661
  • [3] FLOW DEPENDENCE OF MEASURES OF AORTIC-STENOSIS SEVERITY DURING EXERCISE
    BURWASH, IG
    PEARLMAN, AS
    KRAFT, CD
    MIYAKEHULL, C
    HEALY, NL
    OTTO, CM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 24 (05) : 1342 - 1350
  • [4] DEPENDENCE OF GORLIN FORMULA AND CONTINUITY EQUATION VALVE AREAS ON TRANSVALVULAR VOLUME FLOW-RATE IN VALVULAR AORTIC-STENOSIS
    BURWASH, IG
    THOMAS, DD
    SADAHIRO, M
    PEARLMAN, AS
    VERRIER, ED
    THOMAS, R
    KRAFT, CD
    OTTO, CM
    [J]. CIRCULATION, 1994, 89 (02) : 827 - 835
  • [5] Burwash IG, 2000, CAN J CARDIOL, V16, P985
  • [6] CHAMBERS JB, 1992, BRIT HEART J, V67, P193
  • [7] USEFULNESS OF DOBUTAMINE ECHOCARDIOGRAPHY IN DISTINGUISHING SEVERE FROM NONSEVERE VALVULAR AORTIC-STENOSIS IN PATIENTS WITH DEPRESSED LEFT-VENTRICULAR FUNCTION AND LOW TRANSVALVULAR GRADIENTS
    DEFILIPPI, CR
    WILLETT, DL
    BRICKNER, E
    APPLETON, CP
    YANCY, CW
    EICHHORN, EJ
    GRAYBURN, PA
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (02) : 191 - 194
  • [8] Analysis of the effect of flow rate on the Doppler continuity equation for stenotic orifice area calculations - A numerical study
    DeGroff, CG
    Shandas, R
    Valdes-Cruz, L
    [J]. CIRCULATION, 1998, 97 (16) : 1597 - 1605
  • [9] THEORETICAL AND PRACTICAL DIFFERENCES BETWEEN THE GORLIN FORMULA AND THE CONTINUITY EQUATION FOR CALCULATING AORTIC AND MITRAL-VALVE AREAS
    DUMESNIL, JG
    YOGANATHAN, AP
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 67 (15) : 1268 - 1272
  • [10] Effect of three-dimensional valve shape on the hemodynamics of aortic stenosis: Three-dimensional echocardiographic stereolithography and patient studies
    Gilon, D
    Cape, EG
    Handschumacher, MD
    Song, JK
    Solheim, J
    VanAuker, M
    King, MEE
    Levine, RA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (08) : 1479 - 1486