Comparative meta-analysis of balloon-expandable and self-expandable valves for transcatheter aortic valve replacement

被引:22
|
作者
Agarwal, Shikhar [1 ]
Parashar, Akhil [2 ]
Kumbhani, Dharam J. [4 ]
Svensson, Lars G. [3 ]
Krishnaswamy, Amar [1 ]
Tuzcu, E. Murat [1 ]
Kapadia, Samir R. [1 ]
机构
[1] Cleveland Clin, Inst Heart & Vasc, Dept Cardiovasc Med, Cleveland, OH 44195 USA
[2] Cleveland Clin, Dept Internal Med, Cleveland, OH 44195 USA
[3] Cleveland Clin, Dept Cardiovasc Surg, Cleveland, OH 44195 USA
[4] UT Southwestern Med Ctr, Intervent Cardiol, Dallas, TX USA
关键词
TAVR; Percutaneous valves; Aortic stenosis; Sapien; Core Valve; HIGH-RISK PATIENTS; PERMANENT PACEMAKER IMPLANTATION; EXPANDING COREVALVE PROSTHESIS; OUTCOME SOURCE REGISTRY; EDWARDS SAPIEN VALVE; MEDTRONIC-COREVALVE; PREDICTIVE FACTORS; EUROPEAN REGISTRY; CLINICAL-OUTCOMES; REVALVING SYSTEM;
D O I
10.1016/j.ijcard.2015.06.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Balloon-expandable valves (BEVs) and self-expandable valves (SEVs) are two major types of valves utilized for transcatheter aortic valve replacement (TAVR). We conducted a meta-analysis of available studies to compare the safety and efficacy of these two valve types. Methods: Medline search was conducted using standard search terms to determine eligible studies. Primary outcomes of the meta-analysis included death and stroke at 30 days and 1 year. Pooled estimates of procedural outcomes were also compared between the valve types. Analysis was performed for entire cohort and separately for patients undergoing transfemoral TAVR (TF-TAVR). Results: Analysis of entire cohort revealed similar 30-day mortality in the SEV and BEV cohorts. There was no significant difference in the incidence of stroke at 30 days between the two study groups. Both pooled comparisons demonstrated a significant heterogeneity with I-2 > 50%, necessitating the use of random effect modeling. We observed a significantly higher incidence of new pacemaker implantation, aortic regurgitation >= 2 + at 30 days, valve embolization, and need for >1 valve following SEV implantation compared with BEV implantation. Analysis of TF-TAVR cohort showed higher 30 day [IRR (95% CI): 1.34 (1.19-1.52)] but a similar 1-year mortality [IRR (95% CI): 1.07 (0.96-1.19)] for SEV compared to BEV implantation. Conclusion: Compared to BEV implantation, SEV implantation was associated with a similar risk of mortality and stroke at 30-day and 1-year follow-up duration. Analysis of the TF-TAVR cohort revealed a significantly higher mortality at 30 days among patients undergoing SEV implantation, compared with BEV implantation. In addition, there was a significantly higher incidence of other adverse events noted above, following SEV implantation, compared with BEV implantation. (C) 2015 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:87 / 97
页数:11
相关论文
共 50 条
  • [31] Self-Expandable vs Balloon-Expandable Valves in Patients With Small Annuli Undergoing Transfemoral Transcatheter Aortic Valve Implantation
    Hemelrijk, Kimberley
    Aarts, Hugo
    van Nieuwkerk, Astrid
    Broeze, Gijs
    Ruiz Quevedo, Valeriano
    Tchetche, Didier
    Sandoli, Fabio
    Barbanti, Marco
    Kornowski, Ran
    Latib, Azeem
    D'Onofrio, Augusto
    Ribichini, Flavio
    Rocio, Huv
    Dumonteil, Nicolas
    Abizaid, Alexandre
    Sartori, Samantha
    d'Errigo, Paola
    Tarantini, Giuseppe
    del Sole, Paolo Alberto
    Orvin, Katia
    Pagnesi, Matteo
    Cruz Gonzalez, Ignacio
    Nombela-Franco, Luis
    Dangas, George
    Mehran, Roxana
    Voskuil, Michiel
    Delewi, Ronak
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B396 - B397
  • [32] Permanent pacemaker implantation following transcatheter aortic valve implantation using self-expandable, balloon-expandable, or mechanically expandable devices: a network meta-analysis
    Ravaux, Justine M.
    Di Mauro, Michele
    Vernooy, Kevin
    Kats, Suzanne
    Mariani, Silvia
    Ronco, Daniele
    Dato, Giulia Actis
    Simons, Jorik
    Van't Hof, Arnoud W.
    Maessen, Jos G.
    Lorusso, Roberto
    EUROPACE, 2021, 23 (12): : 1998 - 2009
  • [33] Balloon-expandable or self-expandable transcatheter heart valves. Which are best?
    Webb, John
    Wood, David
    Sathananthan, Janarthanan
    Landes, Uri
    EUROPEAN HEART JOURNAL, 2020, 41 (20) : 1900 - 1902
  • [34] Balloon-expandable versus Self-expandable Transcatheter Aortic Valve Prostheses: Comparison of periinterventional Outcomes
    Kuntscher, A.
    Lassnig, E.
    Porodko, M.
    Srndic, E.
    Geissler, H. K.
    Binder, R. K.
    WIENER KLINISCHE WOCHENSCHRIFT, 2023, 135 : S391 - S391
  • [35] Balloon-Expandable Prostheses for Transcatheter Aortic Valve Replacement
    Ribeiro, Henrique Barbosa
    Urena, Marina
    Allende, Ricardo
    Amat-Santos, Ignacio J.
    Rodes-Cabau, Josep
    PROGRESS IN CARDIOVASCULAR DISEASES, 2014, 56 (06) : 583 - 595
  • [36] Efficacy of self-expandable versus balloon-expandable Transcatheter aortic valve replacement in severe aortic stenosis patients: A systematic review and meta-analysis of randomized control trials
    Scardini, Pedro Gabriel
    Prata, Alonzo
    Katsuyama, Eric
    Coan, Ana Carolina
    Fukunaga, Christian
    Neto, Wilson Falco
    Fernandes, Julia
    Pinheiro, Rafael Petri Santos
    Andrade, Naieli
    Gioli-Pereira, Luciana
    CIRCULATION, 2024, 150
  • [38] Combination Use of Inoue-Balloon and Self-Expandable Transcatheter Valves in Managing Aortic Stenosis Not Amenable to Balloon-Expandable Valves
    Saji, Mike
    Highchi, Ryosuke
    Iguchi, Nobuo
    Takamisawa, Itaru
    Shimizu, Jun
    Shimokawa, Tomoki
    Nanasato, Mamoru
    Takayama, Morimasa
    Isobe, Mitsuaki
    INTERNATIONAL HEART JOURNAL, 2022, 63 (05) : 843 - 851
  • [39] Comparison of Outcomes of Balloon-Expandable Versus Self-Expandable Transcatheter Heart Valves for Severe Aortic Stenosis
    Wijeysundera, Harindra C.
    Qiu, Feng
    Koh, Maria
    Prasad, Treesa J.
    Cantor, Warren J.
    Cheema, Asim
    Chu, Michael W. A.
    Czarnecki, Andrew
    Feindel, Christopher
    Fremes, Stephen E.
    Kingsbury, Kori J.
    Natarajan, Madhu K.
    Peterson, Mark
    Ruel, Marc
    Strauss, Bradley
    Ko, Dennis T.
    AMERICAN JOURNAL OF CARDIOLOGY, 2017, 119 (07): : 1094 - 1099
  • [40] Safety and efficacy of self-expandable Evolut R vs. balloon-expandable Sapien 3 valves for transcatheter aortic valve implantation: A systematic review and meta-analysis
    He, Chenglin
    Xiao, Lang
    Liu, Junli
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2019, 18 (05) : 3893 - 3904