Topographic analysis and evaluation of anatomical landmarks for placement of central venous catheters based on conventional chest X-ray and computed tomography

被引:25
作者
Dulce, M. [1 ]
Steffen, I. G. [1 ]
Preuss, A. [1 ]
Renz, D. M. [1 ]
Hamm, B. [1 ]
Elgeti, T. [1 ]
机构
[1] Charite, Dept Radiol, D-12203 Berlin, Germany
关键词
central venous catheter; chest; computed tomography; sternoclavicular joint; X-ray; SUPERIOR VENA-CAVA; CARDIAC-TAMPONADE; INSERTION DEPTH; CARINA; MAGNIFICATION; GUIDANCE; TIP;
D O I
10.1093/bja/aet341
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Positioning central venous catheters (CVCs) in the proper part of the superior vena cava (SVC) is difficult. The aim of this exploratory study was to analyse topographic relationships of the extrapericardial SVC using chest X-ray (CXR) and computed tomography (CT). This included an appraisal of rules for optimal CVC tip placement. Methods. We retrospectively evaluated 100 patients with CVCs who underwent bedside CXR and CT on the same day. Distances between the sternoclavicular joint (SCJ), tracheal carina, SVC origin, pericardial reflection, and CVC tip were analysed on CT and, if visible, on CXR. These measurements served to locate the extrapericardial SVC in relation to anatomical landmarks. Different strategies for CVC tip positioning were evaluated. Results. The mean (standard deviation) extrapericardial length of the SVC was 26 (12) mm. The average position of the pericardial reflection was 5 mm below the carina (range, 29 mm below to 25 mm above). In our patient population, the best results in terms of tip positions in the extrapericardial SVC would have been achieved by using 85% of the SCJ-to-carina distance (in 86%) or by positioning the CVC tip 9 mm above the carina (in 84% of patients). Conclusions. The extrapericardial part of the SVC varies considerably in length and position, and rules of thumb based on anatomical landmarks should be used cautiously. In our series, using 85% of the SCJ-to-carina distance or placing the CVC tip 9 mm above the carina would have resulted in a high percentage of positions in the extrapericardial SVC.
引用
收藏
页码:265 / 271
页数:7
相关论文
共 24 条
[1]   Applied anatomy of the superior vena cava -: the carina as a landmark to guide central venous catheter placement [J].
Albrecht, K ;
Nave, H ;
Breitmeier, D ;
Panning, B ;
Tröger, HD .
BRITISH JOURNAL OF ANAESTHESIA, 2004, 92 (01) :75-77
[2]  
ALDRIDGE HE, 1986, CAN MED ASSOC J, V135, P1082
[3]   MRI of central venous anatomy - Implications for central venous catheter insertion [J].
Aslamy, Z ;
Dewald, CL ;
Heffner, JE .
CHEST, 1998, 114 (03) :820-826
[4]   Implication of the anatomy of the pericardial reflection on positioning of central venous catheters [J].
Bayer, Ole ;
Schummer, Claudia ;
Richter, Konrad ;
Froeber, Rosemarie ;
Schummer, Wolfram .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2006, 20 (06) :777-780
[5]   Evaluation and Management of Central Venous Access Complications [J].
Bhutta, Sadaf T. ;
Culp, William C. .
TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 14 (04) :217-224
[6]  
Bland JMAD, 1986, LANCET, V327, P307
[7]   Central venous catheterization and fatal cardiac tamponade [J].
Booth, SA ;
Norton, B ;
Mulvey, DA .
BRITISH JOURNAL OF ANAESTHESIA, 2001, 87 (02) :298-302
[8]   A better landmark for positioning a central venous catheter [J].
Caruso L.J. ;
Gravenstein N. ;
Layon A.J. ;
Peters K. ;
Gabrielli A. .
Journal of Clinical Monitoring and Computing, 2002, 17 (06) :331-334
[9]   Cardiac tamponade from central venous catheters [J].
Collier, PE ;
Blocker, SH ;
Graff, DM ;
Doyle, P .
AMERICAN JOURNAL OF SURGERY, 1998, 176 (02) :212-214
[10]   Thoracic Aortic Aneurysm Clinically Pertinent Controversies and Uncertainties [J].
Elefteriades, John A. ;
Farkas, Emily A. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (09) :841-857