Image quality assurance of soft copy display systems

被引:14
作者
Seto, E [1 ]
Ursani, A
Cafazzo, JA
Rossos, PG
Easty, AC
机构
[1] Univ Hlth Network, Med Device Informat Grp, Dept Med, Toronto, ON, Canada
[2] Univ Hlth Network, Med Device Informat Grp, Dept Med Engn, Toronto, ON, Canada
[3] Univ Hlth Network, Ctr Global eHealth Innovat, Toronto, ON, Canada
[4] Univ Toronto, Dept Hlth Policy Management & Evaluat, Toronto, ON, Canada
[5] Univ Toronto, Fac Med, Toronto, ON, Canada
[6] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON, Canada
关键词
image quality; display system; calibration; quality control; quality assurance; monitor; medical imaging; softcopy; cathode ray tube; liquid crystal display; DICOM; 14; Grayscale Standard Display Function; SMPTE; luminance;
D O I
10.1007/s10278-005-6705-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Image quality assurance has traditionally been a high priority in medical imaging departments. Recently, it has often been neglected with the transition from hard copy (film) to soft copy (computer) display systems, which could potentially result in difficulty in reading images or even misdiagnosis. This transition therefore requires careful management such that comparable image quality is achieved at a minimum. It is particularly difficult to maintain appropriate image quality in the clinical settings outside of medical imaging departments because of the volume of display systems and the financial restraints that prohibit the widespread use of dedicated computers and high-quality monitors. In this study, a protocol to test and calibrate display systems was developed and validated by using an inexpensive calibration tool. Using this protocol, monitors were identified in a hospital in which image quality was found to be inadequate for medical image viewing. It was also found that most monitors could achieve a substantial increase in image quality after calibration. For example, the 0 and 5% luminance difference was discernable on 30% of the piloted display systems before calibration, but it was discernable on 100% post calibration. In addition, about 50% of the piloted display systems did not have the maximum luminance (white level) suitably set, and 35% of them did not have the minimum luminance (dark level) suitably set. The results indicate that medical display systems must be carefully selected and strictly monitored, maintained, and calibrated to ensure adequate image quality.
引用
收藏
页码:280 / 286
页数:7
相关论文
共 11 条
  • [1] *AAPM, 2002, TASK GROUP 18 ASS DI
  • [2] Practical aspects of grayscale calibration of display systems
    Blume, H
    Ho, AMK
    Stevens, F
    Steven, PM
    [J]. MEDICAL IMAGING 2001: PACS AND INTEGRATED MEDICAL INFORMATION SYSTEMS: DESIGN AND EVALUATION, 2001, 4323 : 28 - 41
  • [3] Effect of room illuminance on monitor black level luminance and monitor calibration
    Chakrabarti, K
    Kaczmarek, RV
    Thomas, JA
    Romanyukha, A
    [J]. JOURNAL OF DIGITAL IMAGING, 2003, 16 (04) : 350 - 355
  • [4] Practical usage of image quality verification tools.
    Compton, K
    Hemminger, BM
    Oosterwijk, H
    [J]. MEDICAL IMAGING 2001: PACS AND INTEGRATED MEDICAL INFORMATION SYSTEMS: DESIGN AND EVALUATION, 2001, 4323 : 148 - 150
  • [5] TEST PATTERN FOR VIDEO DISPLAYS AND HARD-COPY CAMERAS
    GRAY, JE
    LISK, KG
    HADDICK, DH
    HARSHBARGER, JH
    OOSTERHOF, A
    SCHWENKER, R
    [J]. RADIOLOGY, 1985, 154 (02) : 519 - 527
  • [6] Acceptance testing for soft copy displays
    Mertelmeier, T
    Scharl, P
    [J]. MEDICAL IMAGING 2001: VISUALIZATION, DISPLAY, AND IMAGE-GUIDED PROCEDURES, 2001, 4319 : 525 - 535
  • [7] QUALITY-CONTROL OF CATHODE-RAY TUBE MONITORS FOR MEDICAL IMAGING USING A SIMPLE PHOTOMETER
    PARSONS, DM
    KIM, Y
    HAYNOR, DR
    [J]. JOURNAL OF DIGITAL IMAGING, 1995, 8 (01) : 10 - 20
  • [8] Design and implementation of a multi-task radiology workstation ergonomically tailored for fully digital reading rooms
    Ratib, O
    Amato, C
    Balbona, JA
    Boots, K
    McCoy, JM
    [J]. MEDICAL IMAGING 2001: PACS AND INTEGRATED MEDICAL INFORMATION SYSTEMS: DESIGN AND EVALUATION, 2001, 4323 : 93 - 96
  • [9] STEVEN PM, 1996, MONITOR CALIBRATION, P207
  • [10] WANG CY, 2002, ACTA SEISMOLOGICA SI, V15, P1, DOI DOI 10.3321/J.ISSN:0253-3782.2002.01.001