Psychosocial factors and indoor environmental quality in respiratory symptom reports of pupils: a cross-sectional study in Finnish schools

被引:8
作者
Savelieva, Kateryna [1 ]
Elovainio, Marko [2 ]
Lampi, Jussi [3 ]
Ung-Lanki, Sari [3 ]
Pekkanen, Juha [1 ,3 ]
机构
[1] Univ Helsinki, Dept Publ Hlth, Fac Med, Helsinki, Finland
[2] Univ Helsinki, Dept Psychol & Logoped, Fac Med, Helsinki, Finland
[3] Finnish Inst Hlth & Welf, Dept Hlth Secur, Environm Hlth Unit, Kuopio, Pohjois Savo, Finland
关键词
public health; respiratory infections; social medicine; SICK BUILDING SYNDROME; AIR PROBLEMS; HEALTH; WORK; SCHOOLCHILDREN; MOISTURE; DAMPNESS; MOLD;
D O I
10.1136/bmjopen-2020-036873
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives Poor indoor environmental quality (IEQ) in schools is related to higher respiratory symptoms of pupils, but little is known about the importance of other factors. This study examined the associations between different psychosocial factors and other pupils' individual and allergic characteristics, beyond school IEQ, and reporting of respiratory symptoms in pupil-administered and parent-administered questionnaires. Setting All primary and secondary schools in two areas of Helsinki, Finland. Participants Primary school pupils (grade 3-6, n=8775, 99 school buildings) and secondary school pupils (grade 7-9, n=3410, 30 school buildings) reported their respiratory symptoms, as well as psychosocial factors and individual characteristics. Parents of primary school pupils (grade 1-6, n=3540, 88 school buildings) also filled in questionnaires, but the response rate was low (20% in 2017 and 13% in 2018). Main outcome measure Respiratory symptoms were reported in relation to the school environment and in general (without such relation) by pupils or parents. Results Worry about IEQ and low school satisfaction, and asthma and hay fever were related to higher reporting of respiratory symptoms in three samples. The variance between schools in respiratory symptoms was low (intraclass correlation=0.6%-2.4%). Psychosocial factors, especially worry about school's IEQ, explained more of the variance between schools in symptoms than IEQ among secondary school pupils and parents, but not among primary school pupils for symptoms in general. Worry about IEQ also modified the associations between IEQ and respiratory symptoms, but only in parental reports. Conclusion In addition to IEQ, psychosocial factors and pupils' individual and allergic characteristics were related to higher reporting of respiratory symptoms in all three samples. Psychosocial factors explained more variance between schools than IEQ, although it was 2.4% at most. Other factors beyond IEQ should be considered when interpreting symptom reporting in indoor air questionnaires.
引用
收藏
页数:13
相关论文
共 46 条
[1]   Intermediate and advanced topics in multilevel logistic regression analysis [J].
Austin, Peter C. ;
Merlo, Juan .
STATISTICS IN MEDICINE, 2017, 36 (20) :3257-3277
[2]   Dampness and mould in schools and respiratory symptoms in children: the HITEA study [J].
Borras-Santos, Alicia ;
Jacobs, Jose H. ;
Taubel, Martin ;
Haverinen-Shaughnessy, Ulla ;
Krop, Esmeralda J. M. ;
Huttunen, Kati ;
Hirvonen, Maija-Riitta ;
Pekkanen, Juha ;
Heederik, Dick J. J. ;
Zock, Jan-Paul ;
Hyvarinen, Anne .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2013, 70 (10) :681-687
[3]   Why do women suffer from sick building syndrome more often than men? Subjective higher sensitivity versus objective causes [J].
Brasche, S ;
Bullinger, M ;
Morfeld, M ;
Gebhardt, HJ ;
Bischof, W .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 2001, 11 (04) :217-222
[4]   Assessment of Indoor Air Quality Problems in Office-Like Environments: Role of Occupational Health Services [J].
Carrer, Paolo ;
Wolkoff, Peder .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2018, 15 (04)
[5]   Psychosocial factors and the ''sick building-syndrome''. A case-referent study [J].
Eriksson, N ;
Hoog, J ;
Stenberg, B ;
Sundell, J .
INDOOR AIR, 1996, 6 (02) :101-110
[6]   The associations of indoor environment and psychosocial factors on the subjective evaluation of Indoor Air Quality among lower secondary school students: a multilevel analysis [J].
Finell, E. ;
Haverinen-Shaughnessy, U. ;
Tolvanen, A. ;
Laaksonen, S. ;
Karvonen, S. ;
Sund, R. ;
Saaristo, V. ;
Luopa, P. ;
Stahl, T. ;
Putus, T. ;
Pekkanen, J. .
INDOOR AIR, 2017, 27 (02) :329-337
[7]   Psychosocial Problems, Indoor Air-Related Symptoms, and Perceived Indoor Air Quality among Students in Schools without Indoor Air Problems: A Longitudinal Study [J].
Finell, Eerika ;
Tolvanen, Asko ;
Pekkanen, Juha ;
Minkkinen, Jaana ;
Stahl, Timo ;
Rimpela, Arja .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2018, 15 (07)
[8]   The ventilation problem in schools: literature review [J].
Fisk, W. J. .
INDOOR AIR, 2017, 27 (06) :1039-1051
[9]   Does dampness and mold in schools affect health? Results of a meta-analysis [J].
Fisk, William J. ;
Chan, Wanyu R. ;
Johnson, Alexandra L. .
INDOOR AIR, 2019, 29 (06) :895-902
[10]   Association of residential dampness and mold with respiratory tract infections and bronchitis: a meta-analysis [J].
Fisk, William J. ;
Eliseeva, Ekaterina A. ;
Mendell, Mark J. .
ENVIRONMENTAL HEALTH, 2010, 9