Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: source dosimetry, treatment planning, equipment performance and in vivo verification techniques

被引:42
作者
Palmer, Antony [1 ,2 ]
Bradley, David [1 ]
Nisbet, Andrew [1 ,3 ]
机构
[1] Univ Surrey, Fac Engn & Phys Sci, Dept Phys, Guildford GU2 5XH, Surrey, England
[2] Portsmouth Hosp NHS Trust, Queen Alexandra Hosp, Dept Med Phys, Portsmouth, Hants, England
[3] Royal Surrey Cty Hosp NHS Fdn Trust, Dept Med Phys, Guildford, Surrey, England
关键词
accuracy; brachytherapy; dosimetry; high dose rate (HDR); in vivo; treatment planning; MONTE-CARLO DOSIMETRY; RATE IR-192 SOURCE; RADIATION-THERAPY; RADIOCHROMIC FILM; QUALITY-ASSURANCE; ANISOTROPY FUNCTION; WATER CALORIMETRY; ANNIVERSARY PAPER; PROSTATE-CANCER; AIDED DOSIMETRY;
D O I
10.5114/jcb.2012.29364
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This study provides a review of recent publications on the physics-aspects of dosimetric accuracy in high dose rate (HDR) brachytherapy. The discussion of accuracy is primarily concerned with uncertainties, but methods to improve dose conformation to the prescribed intended dose distribution are also noted. The main aim of the paper is to review current practical techniques and methods employed for HDR brachytherapy dosimetry. This includes work on the determination of dose rate fields around brachytherapy sources, the capability of treatment planning systems, the performance of treatment units and methods to verify dose delivery. This work highlights the determinants of accuracy in HDR dosimetry and treatment delivery and presents a selection of papers, focusing on articles from the last five years, to reflect active areas of research and development. Apart from Monte Carlo modelling of source dosimetry, there is no clear consensus on the optimum techniques to be used to assure dosimetric accuracy through all the processes involved in HDR brachytherapy treatment. With the exception of the ESTRO mailed dosimetry service, there is little dosimetric audit activity reported in the literature, when compared with external beam radiotherapy verification.
引用
收藏
页码:81 / 91
页数:11
相关论文
共 114 条
  • [51] International Commission on Radiological Protection, 2000, ICRP PUBL, V86
  • [52] *IPEM, 1999, 81 IPEM
  • [53] Establishment of Ge-doped optical fibres as thermoluminescence dosimeters for brachytherapy
    Issa, Fatma
    Rahman, A. T. Abdul
    Hugtenburg, Richard P.
    Bradley, David A.
    Nisbet, Andrew
    [J]. APPLIED RADIATION AND ISOTOPES, 2012, 70 (07) : 1158 - 1161
  • [54] Monte Carlo and TLD dosimetry of an 192Ir high dose-rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Sakelliou, L
    Sandilos, P
    Antypas, C
    Vlachos, L
    Koutsouveli, E
    [J]. MEDICAL PHYSICS, 1998, 25 (10) : 1975 - 1984
  • [55] Identifying afterloading PDR and HDR brachytherapy errors using real-time fiber-coupled Al2O3:C dosimetry and a novel statistical error decision criterion
    Kertzscher, Gustavo
    Andersen, Claus E.
    Siebert, Frank-Andre
    Nielsen, Soren Kynde
    Lindegaard, Jacob C.
    Tanderup, Kari
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 100 (03) : 456 - 462
  • [56] Dosimetric evaluation of a new OneDose MOSFET for Ir-192 energy
    Kinhikar, RA
    Sharma, PK
    Tambe, CM
    Deshpande, DD
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (05) : 1261 - 1268
  • [57] TLD, diode and monte carlo dosimetry of an Ir-192 source for high dose-rate brachytherapy
    Kirov, AS
    Williamson, JF
    Meigooni, AS
    Zhu, Y
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (12) : 2015 - 2036
  • [58] A dose verification method for high-dose-rate brachytherapy treatment plans
    Kumar, Rajesh
    Sharma, S. D.
    Vijaykumar, C.
    Deshpande, Sudesh
    Sharma, P. K.
    Vandana, S.
    Philomena, A.
    Chilkulwar, Ravi H.
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2008, 4 (04) : 173 - 177
  • [59] COMPREHENSIVE QA FOR RADIATION ONCOLOGY - REPORT OF AAPM RADIATION-THERAPY COMMITTEE TASK-GROUP-40
    KUTCHER, GJ
    COIA, L
    GILLIN, M
    HANSON, WF
    LEIBEL, S
    MORTON, RJ
    PALTA, JR
    PURDY, JA
    REINSTEIN, LE
    SVENSSON, GK
    WELLER, M
    WINGFIELD, L
    [J]. MEDICAL PHYSICS, 1994, 21 (04) : 581 - 618
  • [60] Suitability of point kernel dose calculation techniques in brachytherapy treatment planning
    Lakshminarayanan, Thilagam
    Subbaiah, K. V.
    Thayalan, K.
    Kannan, S. E.
    [J]. JOURNAL OF MEDICAL PHYSICS, 2010, 35 (02) : 88 - 99