The choroid in glaucoma

被引:43
作者
Banitt, Michael [1 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Miami, FL 33136 USA
关键词
choroidal thickness; enhanced depth imaging; glaucoma; peripapillary; OPEN-ANGLE GLAUCOMA; BLOOD-FLOW; OPTIC-NERVE; THICKNESS; HEMODYNAMICS; CIRCULATION; DAMAGE; EYES;
D O I
10.1097/ICU.0b013e32835d9245
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose of review Prior studies have not conclusively established a relationship between the choroid and glaucoma. The development of an enhanced imaging technique for spectral domain optical coherence tomography (SD-OCT) has allowed for measurements of choroidal thickness that are more accurate than previously possible. Therefore, the SD-OCT may be capable of documenting the changes in the choroid as they relate to glaucoma. Recent findings When applied to the SD-OCT, the technique of enhanced depth imaging allows for reproducible measurements of choroidal thickness. Nine reports have been published about choroidal thickness within the macula, as measured by OCT, in eyes with glaucoma. In six publications, there was no significant difference between the macular choroidal thicknesses of patients with glaucoma compared with those without glaucoma. Additional five studies have reported on peripapillary choroidal thickness in glaucoma patients. Although three of the studies determined that the peripapillary choroid is thinner in glaucoma patients, two others failed to establish this relationship. Summary The SD-OCT is capable of reproducibly measuring choroidal thickness in the peripapillary and macular areas. In those with glaucoma, choroidal thickness does not change within the macula. In a few subsets of glaucoma, the peripapillary choroid is thinner when compared with normals.
引用
收藏
页码:125 / 129
页数:5
相关论文
共 27 条
[1]   Choroidal Thickness Change after Water Drinking Is Greater in Angle Closure than in Open Angle Eyes [J].
Arora, Karun S. ;
Jefferys, Joan L. ;
Maul, Eugenio A. ;
Quigley, Harry A. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (10) :6393-6402
[2]   Choroidal Thickness in Open-Angle Glaucoma Measured by Spectral-Domain Scanning Laser Ophthalmoscopy/Optical Coherence Tomography [J].
Cennamo, Gilda ;
Finelli, Marialuisa ;
Iaccarino, Gennarfrancesco ;
de Crecchio, Giuseppe ;
Cennamo, Giovanni .
OPHTHALMOLOGICA, 2012, 228 (01) :47-52
[3]   Chronic ischemia induces regional axonal damage in experimental primate optic neuropathy [J].
Cioffi, GA ;
Wang, L ;
Fortune, B ;
Cull, G ;
Dong, J ;
Bui, B ;
Van Buskirk, EM .
ARCHIVES OF OPHTHALMOLOGY, 2004, 122 (10) :1517-1525
[4]   CHOROIDAL THICKNESS IN PRIMARY GLAUCOMA [J].
CRISTINI, G ;
CENNAMO, G ;
DAPONTE, P .
OPHTHALMOLOGICA, 1991, 202 (02) :81-85
[5]   Choroidal haemodynamics in glaucoma [J].
Duijm, HFA ;
vandenBerg, TJTP ;
Greve, EL .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1997, 81 (09) :735-742
[6]   Peripapillary choroidal thickness in glaucoma measured with optical coherence tomography [J].
Ehrlich, Joshua R. ;
Peterson, Jeffrey ;
Parlitsis, George ;
Kay, Kristine Y. ;
Kiss, Szilard ;
Radcliffe, Nathan M. .
EXPERIMENTAL EYE RESEARCH, 2011, 92 (03) :189-194
[7]   Enhanced depth imaging of the choroid in open-angle glaucoma: A preliminary study [J].
Fenolland, J. -R. ;
Giraud, J. -M. ;
May, F. ;
Mouinga, A. ;
Seck, S. ;
Renard, J. -P. .
JOURNAL FRANCAIS D OPHTALMOLOGIE, 2011, 34 (05) :313-317
[8]   Ocular blood flow and systemic blood pressure in patients with primary open-angle glaucoma and ocular hypertension [J].
Fuchsjäger-Mayrl, G ;
Wally, B ;
Georgopoulos, M ;
Rainer, G ;
Kircher, K ;
Buehl, W ;
Amoako-Mensah, T ;
Eichler, HG ;
Vass, C ;
Schmetterer, L .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (03) :834-839
[9]   Ocular hemodynamics and glaucoma prognosis - A color Doppler imaging study [J].
Galassi, F ;
Sodi, A ;
Ucci, F ;
Renieri, G ;
Pieri, B ;
Baccini, M .
ARCHIVES OF OPHTHALMOLOGY, 2003, 121 (12) :1711-1715
[10]  
Grunwald JE, 1998, INVEST OPHTH VIS SCI, V39, P2329