Water Layer Height Measurement in Oil-Water Two-Phase Flows

被引:0
|
作者
Huang, S-F [1 ,2 ]
Lu, J. [3 ]
Zhang, B. D. [2 ]
Wang, D. [2 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Xian 710049, Peoples R China
[3] Beijing Aerosp Inst Metrol & Measurement Technol, Beijing 100076, Peoples R China
来源
7TH INTERNATIONAL SYMPOSIUM ON MEASUREMENT TECHNIQUES FOR MULTIPHASE FLOWS | 2012年 / 1428卷
基金
中国国家自然科学基金;
关键词
Oil-water two-phase flow; oil production logging; water layer height; single-wire capacitance probe;
D O I
10.1063/1.3694691
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Water layer height was measured by a single-wire capacitance probe in horizontal oil-water two-phase flows. The viscosity of oil was up to 140 mPa.s to simulate the actual flow in oil production logging. Typical water-layer-height curves with time were obtained when water was continuous. The accuracy was estimated by a quick-closing valve (QCV) system. Time traces of water layer height were completely consistent with the corresponding flow structures. The statistic parameters, such as amplitude, average, and frequency, were different from each other, which can describe the features of the flow patterns. The single-wire capacitance probe can only detect continuous water, instead of emulsified water in oil. However, the emulsified water had effect on flow structure, indirectly influencing the measurement results. On the basis of the measurements in different flows, the same principle was obeyed including air-water, and oil-water two-phase flows with oil of different viscosities. The detection ability of the probe decreased as interfacial velocity increasing or the size decreasing of the discrete phase, and flow patterns determined the measurement accuracy. The error of estimated water holdup by the probe was -35 similar to 10% and 5 similar to 25% for stratified and dispersed oil in water flows, respectively.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Experimental study on performance of turbine flowmeter and venturi meter in oil-water two-phase flow measurement
    Huang, Zhiyao
    Li, Xia
    Liu, Yian
    Wang, Baoliang
    Li, Haiqing
    MULTIPHASE FLOW: THE ULTIMATE MEASUREMENT CHALLENGE, PROCEEDINGS, 2007, 914 : 678 - +
  • [32] A New Method for Measuring Water Holdup of Oil-Water Two-Phase Flow in Horizontal Wells
    Wang, Yanjun
    Han, Jianlong
    Hao, Zhiqiang
    Zhou, Lijian
    Wang, Xinjie
    Shao, Mingwei
    PROCESSES, 2022, 10 (05)
  • [33] Extracting reference voltages from measurement voltages for oil-water two-phase flow measurement of electrical impedance tomography
    Yu, Hao
    Wan, Xingchen
    Jia, Jiabin
    FLOW MEASUREMENT AND INSTRUMENTATION, 2023, 89
  • [34] Numerical Simulation of the Oil-Water Two-Phase Flow in Horizontal Bend Pipes
    Zhu, Hongjun
    Jing, Jiaqiang
    Yang, Xiaolu
    Chen, Junwen
    COMPUTER SCIENCE FOR ENVIRONMENTAL ENGINEERING AND ECOINFORMATICS, PT 1, 2011, 158 : 75 - 82
  • [35] A novel method to identify the flow pattern of oil-water two-phase flow
    Li, Zhong-Cheng
    Fan, Chun-Ling
    JOURNAL OF PETROLEUM EXPLORATION AND PRODUCTION TECHNOLOGY, 2020, 10 (08) : 3723 - 3732
  • [36] Numerical and Experimental Analysis of Ultrasound Attenuation in Oil-Water Two-Phase Flow
    Shao, Yizhe
    Tan, Chao
    Dong, Feng
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 1536 - 1541
  • [37] Mass Flow Rate Measurement of Oil-Water Two-Phase Flow by a Long-Waist Cone Meter
    Tan, Chao
    Wu, Hao
    Dong, Feng
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2013, 62 (10) : 2795 - 2804
  • [38] Water holdup measurement of oil-water two-phase flow in a horizontal well using a dual-circle conductance probe array
    Xu, Lijun
    Zhang, Wen
    Cao, Zhang
    Zhao, Jiayu
    Xie, Ronghua
    Liu, Xingbin
    Hu, Jinhai
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (11)
  • [39] Horizontal oil-water two-phase flow measurement with information fusion of conductance ring sensor and cone meter
    Tan, Chao
    Wu, Hao
    Dong, Feng
    FLOW MEASUREMENT AND INSTRUMENTATION, 2013, 34 : 83 - 90
  • [40] Flow Velocity Measurement Based on Ultrasonic Cross-correlation Technique in Oil-water Two-phase Flow
    Shi Xuewei
    Dong Xiaoxiao
    Tan Chao
    Dong Feng
    PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 4921 - 4925