Electrochemical characterization of ZrTi alloys for biomedical applications

被引:79
作者
Bolat, Georgiana [1 ,2 ]
Izquierdo, Javier [2 ]
Santana, Juan J. [3 ]
Mareci, Daniel [1 ]
Souto, Ricardo M. [2 ]
机构
[1] Gh Asachi Tech Univ Iasi, Fac Chem Engn & Environm Protect, Iasi 700050, Romania
[2] Univ La Laguna, Dept Phys Chem, E-38205 Tenerife, Canary Islands, Spain
[3] Univ Las Palmas Gran Canaria, Dept Proc Engn, E-35017 Gran Canaria, Canary Islands, Spain
关键词
ZrTi alloys; Corrosion resistance; Cyclic potentiodynamic polarization curves; EIS; Scanning electrochemical microscopy; SEM; IN-VITRO CORROSION; TI-TA ALLOYS; LOCALIZED CORROSION; PASSIVE TITANIUM; BEHAVIOR; RESISTANCE; STABILITY; ZIRCONIUM; SPECTROSCOPY; ZR-2.5NB;
D O I
10.1016/j.electacta.2012.10.026
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The electrochemical behaviour of three ZrTi alloys (Zr5Ti, Zr25Ti and Zr45Ti) in Ringer's solution has been investigated. Their resistance against localized corrosion has been determined from cyclic potentio-dynamic polarization (CCP) and electrochemical impedance spectroscopy (EIS) measurements, whereas scanning electrochemical microscopy (SECM) was applied to investigate the local reactivity of the passive films developed on the materials, and scanning electron microscopy (SEM) was employed to characterize the surface morphology of the alloys subjected to anodic polarization. An increased reactivity could be detected with SECM when the metal samples were polarized at +0.50 V-SHE, though the extent of this feature greatly depended on the nature of the metallic material. In addition, At 37 degrees C, the Zr5Ti alloy was susceptible to localized corrosion. Though Zr25Ti alloy presented rather low pitting potential, the spontaneous corrosion potential of the material was sufficiently negative to require overpotentials around 600 mV for breakdown to occur. Finally, the Zr45Ti alloy exhibited a larger passive range in the polarization curve, and it was resistant to localized corrosion. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:447 / 456
页数:10
相关论文
共 49 条
  • [11] Frankel G.S., 2003, ASM Handbook, P236, DOI [10.31399/ASM.HB.V13A.A0003612, DOI 10.31399/ASM.HB.V13A.A0003612]
  • [12] Ti based biomaterials, the ultimate choice for orthopaedic implants - A review
    Geetha, M.
    Singh, A. K.
    Asokamani, R.
    Gogia, A. K.
    [J]. PROGRESS IN MATERIALS SCIENCE, 2009, 54 (03) : 397 - 425
  • [13] Effects of soluble metals on human peri-implant cells
    Hallab, NJ
    Anderson, S
    Caicedo, M
    Brasher, A
    Mikecz, K
    Jacobs, JJ
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2005, 74A (01) : 124 - 140
  • [14] HALLEYDEMOULIN I, 1994, MATER SCI FORUM, V157-, P521, DOI 10.4028/www.scientific.net/MSF.157-162.521
  • [15] COMBINED ELECTROCHEMICAL AND SURFACE ANALYTICAL INVESTIGATIONS OF THE FORMATION OF PASSIVE LAYERS
    HAUPT, S
    STREHBLOW, HH
    [J]. CORROSION SCIENCE, 1989, 29 (2-3) : 163 - 182
  • [16] Nanostructured Ti-based multi-component alloys with potential for biomedical applications
    He, G
    Eckert, J
    Dai, QL
    Sui, ML
    Loser, W
    Hagiwara, M
    Ma, E
    [J]. BIOMATERIALS, 2003, 24 (28) : 5115 - 5120
  • [17] Structure and properties of cast binary Ti-Mo alloys
    Ho, WF
    Ju, CP
    Lin, JHC
    [J]. BIOMATERIALS, 1999, 20 (22) : 2115 - 2122
  • [18] Kovacs P., 1996, MED APPL TITANIUM IT, P163, DOI DOI 10.1520/STP16077S
  • [19] FORMATION OF IONIC SPACE-CHARGE LAYERS IN OXIDE-FILMS ON VALVE METALS
    LOHRENGEL, MM
    [J]. ELECTROCHIMICA ACTA, 1994, 39 (8-9) : 1265 - 1271
  • [20] Mansfeld F., 1993, TECHNICAL REPORT