Carpentier-Edwards pericardial valves in the mitral position: Ten-year follow-up

被引:17
作者
Aupart, MR
Neville, PH
Hammami, S
Sirinelli, AL
Meurisse, YA
Marchand, MA
机构
[1] Unit de Chirurgie Cardiaque, Hopital Trousseau
关键词
D O I
10.1016/S0022-5223(97)70361-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The first generation of pericardial valves was withdrawn from the market because of a high rate of premature failure, With an original design, Carpentier-Edwards pericardial valves promised improved results, Methods: One hundred fifty patients who underwent isolated mitral valve replacement, between July 1984 and December 1993, with Carpentier-Edwards pericardial bioprostheses in our institution were followed up, Patient mean age was 62.9 +/- 11.9 years, Operative mortality was 3.3%, All but three patients were followed up for an average of 4.7 years after operation, and total follow-up was 710 patient-years, Results: At the time this article was written, over 80% of patients were in New York Heart Association class I or II. After 10 years, actuarial survival rate was 71% (confidence limit 61% to 81%), Valve-related complications included the following: six valve-related deaths (0.8% patient-year), five thromboembolic episodes (0.7% patient-year), three cases of endocarditis (0.4% patient-year), four reoperations (0.5% patient-year), and four structural valve failures with calcification and stenosis (0.5% patient-year), After 10 years, freedom from valve-related complications was 66% (confidence limit 46% to 86%), from valve-related death 94% (confidence limit 89% to 99%), from reoperation 90% (confidence limit 82% to 98%), and from valve failure 76% (confidence limit 62% to 90%), Conclusions: With a low rate of valve-related events at 10 years and a low rate of structural deterioration with no leaflet tear, this prosthesis is a reliable choice for patients over 60 years of age.
引用
收藏
页码:492 / 498
页数:7
相关论文
共 27 条
  • [1] MITRAL-VALVE REPLACEMENT USING A CRYOPRESERVED MITRAL HOMOGRAFT
    ACAR, C
    FARGE, A
    RAMSHEYI, A
    CHACHQUES, JC
    MIHAILEANU, S
    GOUEZO, R
    GEROTA, J
    CARPENTIER, AF
    [J]. ANNALS OF THORACIC SURGERY, 1994, 57 (03) : 746 - 748
  • [2] THE CARPENTIER-EDWARDS PERICARDIAL AORTIC-VALVE - INTERMEDIATE RESULTS IN 420 PATIENTS
    AUPART, M
    NEVILLE, P
    DREYFUS, X
    MEURISSE, Y
    SIRINELLI, A
    MARCHAND, M
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1994, 8 (05) : 277 - 280
  • [3] AUPART M, 1994, NEW HORIZON FUTURE H, P123
  • [4] Barratt-Boyes B G, 1993, J Heart Valve Dis, V2, P604
  • [5] 12-YEAR COMPARISON OF A BJORK-SHILEY MECHANICAL HEART-VALVE WITH PORCINE BIOPROSTHESES
    BLOOMFIELD, P
    WHEATLEY, DJ
    PRESCOTT, RJ
    MILLER, HC
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (09) : 573 - 579
  • [6] FAILURE OF HANCOCK PERICARDIAL XENOGRAFTS - IS PROPHYLACTIC BIOPROSTHETIC REPLACEMENT JUSTIFIED
    BORTOLOTTI, U
    MILANO, A
    GUERRA, F
    MAZZUCCO, A
    MOSSUTO, E
    THIENE, G
    GALLUCCI, V
    [J]. ANNALS OF THORACIC SURGERY, 1991, 51 (03) : 430 - 437
  • [7] BURDON TA, 1992, J THORAC CARDIOV SUR, V103, P238
  • [8] COHN LH, 1985, J THORAC CARDIOV SUR, V90, P872
  • [9] CZER LSC, 1990, J THORAC CARDIOV SUR, V100, P44
  • [10] DELOCHE A, 1990, J THORAC CARDIOV SUR, V99, P990