Experimental study on temperature field of upward flame spread over discrete polystyrene foam

被引:5
作者
An, Weiguang [1 ,2 ,3 ,4 ]
Sun, Jinhua [2 ]
Zhu, Guoqing [1 ]
机构
[1] China Univ Min & Technol, Key Lab Gas & Fire Control Coal Mines, Minist Educ, Xuzhou 221116, Peoples R China
[2] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China
[3] City Univ Hong Kong, Dept Architecture & Civil Engn, Hong Kong 999077, Hong Kong, Peoples R China
[4] Key Lab Bldg Fire Protect Engn & Technol MPS, Tianjin 300381, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Temperature field; Upward flame spread; Discrete fuel; Polystyrene foam; HEAT-TRANSFER; ALTITUDE; ORIENTATION; PYROLYSIS;
D O I
10.1007/s10973-017-6728-z
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this work, thermal analysis methods were used to obtain the temperature field of discrete flame spread across polystyrene (PS) foam inserted with incombustible barrier. The barrier length (L (0)) and the length (L) of PS below were changed to investigate their effects. The frontal temperature field (X-Z plane) showed that in cases where barrier prevented upward flame spread, the flame spread consists of three stages, namely growth stage, heating stage, and attenuation stage (or "upward spreading stage" for failed preventing case). During the heating stage, the area and the height of high-temperature zone (about 630-750 A degrees C) in failed preventing cases were significantly larger than those in prevented cases, while the heating stage duration of the former was shorter. The maximum temperature was observed below the barrier. For XPS with lower length ratio (L/L (0)), the area of the high-temperature zone is larger than that of EPS with higher length ratio. The temperature field of the longitudinal section (Y-Z plane) revealed that the high-temperature zone was localized between -1 and 1 cm of the Y-axis. With the varying of L/L (0) (L/L (0) decreased for XPS while for EPS L/L (0) first dropped and then rose), the vertical distance between the high-temperature zone and the unburned PS surface increased, while the area of the high-temperature zone and the temperature gradient decreased. Thus, the upward flame spread was prevented. These findings are helpful to reveal the mechanism of discrete flame spread.
引用
收藏
页码:2647 / 2656
页数:10
相关论文
共 20 条
  • [1] Flammability and safety design of thermal insulation materials comprising PS foams and fire barrier materials
    An, Weiguang
    Sun, Jinhua
    Liew, K. M.
    Zhu, Guoqing
    [J]. MATERIALS & DESIGN, 2016, 99 : 500 - 508
  • [2] Downward flame spread over extruded polystyrene
    An, Weiguang
    Xiao, Huahua
    Liew, K. M.
    Jiang, Lin
    Yan, Weigang
    Zhou, Yang
    Huang, Xinjie
    Sun, Jinhua
    Gao, Lijing
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2015, 119 (02) : 1091 - 1103
  • [3] Correlation analysis of sample thickness, heat flux, and cone calorimetry test data of polystyrene foam
    An, Weiguang
    Jiang, Lin
    Sun, Jinhua
    Liew, K. M.
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2015, 119 (01) : 229 - 238
  • [4] Flame propagation over liquid alcohols - Part I. Experimental results
    Degroote, E
    Ybarra, PLG
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2005, 80 (03) : 541 - 548
  • [5] Study on the subsurface flow induced by flame spread over aviation kerosene
    Guo, Jin
    Lu, Shouxiang
    Wang, Changjian
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2014, 116 (01) : 455 - 460
  • [6] [韩丽丽 Han Lili], 2013, [中国安全科学学报, China Safety Science Journal(CSSJ)], V23, P48
  • [7] Experimental study of altitude and orientation effects on heat transfer over polystyrene insulation material
    Huang, Xinjie
    Liu, Wei
    Zhao, Jie
    Zhang, Ying
    Sun, Jinhua
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2015, 122 (01) : 281 - 293
  • [8] Effects of altitude and sample orientation on heat transfer for flame spread over polystyrene foams
    Huang, Xinjie
    Zhao, Jie
    Zhang, Ying
    Zhou, Yang
    Wang, Qingsong
    Sun, Jinhua
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2015, 121 (02) : 641 - 650
  • [9] Incropera F.P., 2011, FUNDAMENTALS HEAT MA
  • [10] Ji G, 2012, CONSTR SCI TECHNOL, V7, P49