An improved powered ankle-foot orthosis using proportional myoelectric control

被引:236
作者
Ferris, Daniel P.
Gordon, Keith E.
Sawicki, Gregory S.
Peethambaran, Arnmanath
机构
[1] Univ Michigan, Dept Movement Sci, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Orthot & Prosthet Ctr, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院;
关键词
locomotion; exoskeleton; gait; rehabilitation;
D O I
10.1016/j.gaitpost.2005.05.004
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
We constructed a powered ankle-foot orthosis for human walking with a novel myoelectric controller. The orthosis included a carbon fiber and polypropylene shell, a metal hinge joint, and two artificial pneumatic muscles. Soleus electromyography (EMG) activated the artificial plantar flexor and inhibited the artificial dorsiflexor. Tibialis anterior EMG activated the artificial dorsiflexor. We collected kinematic, kinetic, and electromyographic data for a naive healthy subject walking with the orthosis. The current design improves upon a previous prototype by being easier to don and doff and simpler to use. The novel controller allows naive wearers to quickly adapt to the orthosis without artificial muscle co-contraction. The orthosis may be helpful in studying human walking biomechanics and assisting patients during gait rehabilitation after neurological injury. (C) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:425 / 428
页数:4
相关论文
共 50 条
[21]   Machine-learning-based coordination of powered ankle-foot orthosis and functional electrical stimulation for gait control [J].
Jung, Suhun ;
Bong, Jae Hwan ;
Kim, Keri ;
Park, Shinsuk .
FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 11
[22]   Effect of ankle-foot orthosis on level walking in healthy subjects [J].
Kato, Mizuki ;
Kamono, Arinori ;
Ogihara, Naomichi .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2019, 233 (12) :1262-1268
[23]   An ankle-foot orthosis with inhibitor bar: Effect on hemiplegic gait [J].
Iwata, M ;
Kondo, I ;
Sato, Y ;
Satoh, K ;
Soma, M ;
Tsushima, E .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2003, 84 (06) :924-927
[24]   Ankle-foot orthosis with an oil damper versus nonarticulated ankle-foot orthosis in the gait of patients with subacute stroke: a randomized controlled trial [J].
Yamamoto, Sumiko ;
Motojima, Naoyuki ;
Kobayashi, Yosuke ;
Osada, Yuji ;
Tanaka, Souji ;
Daryabor, Aliyeh .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2022, 19 (01)
[25]   Ankle-foot Orthosis Using Elastomer-Embedded Flexible Joint [J].
Abe, Isao ;
Ishiya, Kohei ;
Oshimoto, Taiki ;
Kikuchi, Takehito ;
Tanida, Sosuke ;
Yasuda, Takashi .
2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, :4499-4502
[26]   Design and Validation of a Two-Degree-of-Freedom Powered Ankle-Foot Orthosis with Two Pneumatic Artificial Muscles [J].
Choi, Ho Seon ;
Lee, Chang Hee ;
Baek, Yoon Su .
MECHATRONICS, 2020, 72 (72)
[27]   Techniques to measure rigidity of ankle-foot orthosis: A review [J].
Kobayashi, Toshiki ;
Leung, Aaron K. L. ;
Hutchins, Stephen W. .
JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2011, 48 (05) :565-576
[28]   A hybrid ankle-foot orthosis with soft pneumatic actuation [J].
Marconi, Grace P. ;
Gopalai, Alpha A. ;
Chauhan, Sunita .
MECHATRONICS, 2024, 99
[29]   Design, implementation, and evaluation of a backstepping control algorithm for an active ankle-foot orthosis [J].
Kirtas, Oguzhan ;
Savas, Yagiz ;
Bayraker, Melih ;
Baskaya, Faik ;
Basturk, Halil ;
Samur, Evren .
CONTROL ENGINEERING PRACTICE, 2021, 106
[30]   Oscillator-Based Transparent Control of an Active/Semiactive Ankle-Foot Orthosis [J].
Zhang, Yufeng ;
Nolan, Karen J. ;
Zanotto, Damian .
IEEE ROBOTICS AND AUTOMATION LETTERS, 2019, 4 (02) :247-253