Auditory steady-state responses and clinical applications

被引:37
作者
Canale, Andrea [1 ]
Lacilla, Michelangelo [1 ]
Cavalot, Andrea Luigi [1 ]
Albera, Roberto [1 ]
机构
[1] Univ Turin, Dept Clin Physiopathol, Sect ENT 2, Turin, Italy
关键词
auditory steady-state responses; objective frequency-specific audiometry; sensory-neural hearing loss;
D O I
10.1007/s00405-006-0017-y
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
The auditory steady-state responses to single continuous tones modulated in amplitude have been proposed as an alternative to objective frequency-specific audiometry. The aim of this study was to compare thresholds obtained by pure-tone audiometry (PTA) and by auditory steady-state responses in normal hearing or affected by hearing loss in adults and in order to evaluate the applicability of this objective test in no collaborative hearing-impaired subjects. Eleven people, 6 normal hearing and 5 with hearing loss, underwent PTA and multiple frequency auditory steady-state responses; simultaneous carrier tones (0.5, 1, 2 and 4 KHz) modulated in amplitude at different rates (77-105 Hz) were presented monaurally (TDH 49 earphones) at variable intensities (110-20 dB SPL). The mean threshold difference between PTA and multiple frequency auditory steady-state responses was 28 dB (standard deviation=14.2) and R correlation value at 0.5-1-2-4 kHz was 0.71 (P=0.0012) at the Pearson's test. These differences were significantly smaller considering the hearing-impaired separately (11.7 dB, standard deviation=2.9). The results of this study confirm previous reports showing that the multiple auditory steady-state response method is an accurate predictor of the behavioural audiogram in patients with sensory-neural hearing impairments and can be used as a valid support for behavioural evaluations.
引用
收藏
页码:499 / 503
页数:5
相关论文
共 15 条
  • [1] Albera R, 1991, Acta Otorhinolaryngol Ital, V11, P543
  • [2] Albera R, 1991, Acta Otorhinolaryngol Ital, V11, P551
  • [3] A COMPARISON OF STEADY-STATE EVOKED-POTENTIALS TO MODULATED TONES IN AWAKE AND SLEEPING HUMANS
    COHEN, LT
    RICKARDS, FW
    CLARK, GM
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1991, 90 (05) : 2467 - 2479
  • [4] Auditory steady-state responses and word recognition scores in normal-hearing and hearing-impaired adults
    Dimitrijevic, A
    John, MS
    Picton, TW
    [J]. EAR AND HEARING, 2004, 25 (01) : 68 - 84
  • [5] Auditory steady-state response thresholds of adults with sensorineural hearing impairments
    Herdman, AT
    Stapells, DR
    [J]. INTERNATIONAL JOURNAL OF AUDIOLOGY, 2003, 42 (05) : 237 - 248
  • [6] Hood L.J., 1998, CLIN APPL AUDITORY B, P67
  • [7] Recording auditory steady-state responses in young infants
    John, MS
    Brown, DK
    Muir, PJ
    Picton, TW
    [J]. EAR AND HEARING, 2004, 25 (06) : 539 - 553
  • [8] Frequency-specific audiometry using steady-state responses
    Lins, OG
    Picton, TW
    Boucher, BL
    DurieuxSmith, A
    Champagne, SC
    Moran, LM
    PerezAbalo, MC
    Martin, V
    Savio, G
    [J]. EAR AND HEARING, 1996, 17 (02) : 81 - 96
  • [9] Hearing assessment by recording multiple auditory steady-state responses: the influence of test duration
    Luts, H
    Wouters, J
    [J]. INTERNATIONAL JOURNAL OF AUDIOLOGY, 2004, 43 (08) : 471 - 478
  • [10] Steady state responses to multiple amplitude-modulated tones:: An optimized method to test frequency-specific thresholds in hearing-impaired children and normal-hearing subjects
    Perez-Abalo, MC
    Savio, G
    Torres, A
    Martín, V
    Rodríguez, E
    Galán, L
    [J]. EAR AND HEARING, 2001, 22 (03) : 200 - 211