Real-time on-line blend uniformity monitoring using near-infrared reflectance spectrometry: A noninvasive off-line calibration approach

被引:65
作者
Sulub, Yusuf [1 ]
Wabuyele, Busolo [1 ]
Gargiulo, Paul [1 ]
Pazdan, James [1 ]
Cheney, James [2 ]
Berry, Joseph [3 ]
Gupta, Abhay [4 ]
Shah, Rakhi [4 ]
Wu, Huiquan [4 ]
Khan, Mansoor [4 ]
机构
[1] Novartis Pharmaceut, Pharmaceut & Analyt Dev, E Hanover, NJ 07936 USA
[2] Novartis Pharmaceut, Global Qual Operat, E Hanover, NJ 07936 USA
[3] QRxPharma Inc, Somerset, NJ USA
[4] US FDA, Div Prod Qual Res, Ctr Drug Evaluat & Res, Silver Spring, MD 20993 USA
关键词
Pharmaceutical; Blend uniformity; Near-infrared; Partial least-squares; Off-line calibration; ANALYTICAL TECHNOLOGY APPROACH; PART II; HOMOGENEITY; SPECTROSCOPY; PREDICTION;
D O I
10.1016/j.jpba.2008.10.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A robust, noninvasive, real-time, on-line near-infrared (NIR) quantitative method is described for blend uniformity monitoring of a pharmaceutical solid dosage form containing 29.4% (w/w) drug load with three major excipients (crospovidone, lactose, and microcrystalline cellulose). A set of 21 off-line. static calibration samples were used to develop a multivariate partial least-squares (PLS) calibration model for on-line prediction of the API content during the blending process. The concentrations of the API and the three major excipients were varied randomly to minimize correlations between the components. A micro electrical-mechanical system (MEMS) based portable, battery operated NIR spectrometer was used for this study. To minimize spectral differences between the static and dynamic measurement modes, the acquired NIR spectra were preprocessed using standard normal variate (SNV) followed by second derivative Savitzky-Golay using 21 points. The performance of the off-line PLS calibration model were evaluated in real-time on 16 laboratory scale (30 L bin size) blend experiments conducted over 3 months. To challenge the robustness of the off-line calibration model, several blend experiments were conducted using a different bin size, faster revolution speed and variations in the potency of the API. Employing the PLS calibration model developed using the off-line calibration approach, the real-time API NIR (%) predictions for all experiments were all within 90-110%. These results were confirmed using the conventional thief sampling of the final blend followed by high performance liquid chromatography (HPLC) analysis. Further confirmation was established through content uniformity by HPLC of manufactured tablets. Finally, the optimized off-line PLS method was successfully transferred to a production site which involved using a secondary NIR instrument with a 15-fold scale-up in bin size from development. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:48 / 54
页数:7
相关论文
共 18 条
[1]  
[Anonymous], 1997, Federal Register, V62, P27463
[2]  
BERMAN J, 1997, 25 PDA, P51
[3]   Quantitative in-line monitoring of powder blending by near infrared reflection spectroscopy [J].
Berntsson, O ;
Danielsson, LG ;
Lagerholm, B ;
Folestad, S .
POWDER TECHNOLOGY, 2002, 123 (2-3) :185-193
[4]   A homogeneity study using NIR spectroscopy: Tracking magnesium stearate in Bohle bin-blender [J].
Duong, NH ;
Arratia, P ;
Muzzio, F ;
Lange, A ;
Timmermans, J ;
Reynolds, S .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2003, 29 (06) :679-687
[5]   A Process Analytical Technology approach to near-infrared process control of pharmaceutical powder blending. Part III: Quantitative near-infrared calibration for prediction of blend homogeneity and characterization of powder mixing kinetics [J].
El-Hagrasy, AS ;
Drennen, JK .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2006, 95 (02) :422-434
[6]   A Process Analytical Technology approach to near-infrared process control of pharmaceutical powder blending: Part II: Qualitative near-infrared models for prediction of blend homogeneity [J].
El-Hagrasy, AS ;
Delgado-Lopez, M ;
Drennen, JK .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2006, 95 (02) :407-421
[7]   The effect of beam size on real-time determination of powder blend homogeneity by an online near infrared sensor [J].
Li, Weiyong ;
Johnson, Mark C. ;
Bruce, Rick ;
Rasmussen, Henrik ;
Worosila, Gregory D. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (02) :711-717
[8]   Mass-balanced blend uniformity analysis of pharmaceutical powders by at-line near-infrared spectroscopy with a fiber-optic probe [J].
Li, Weiyong ;
Johnson, Mark C. ;
Bruce, Rick ;
Ulrich, Steven ;
Rasmussen, Henrik ;
Worosila, Gregory D. .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2006, 326 (1-2) :182-185
[9]  
Martens H., 1989, MULTIVARIATE CALIBRA
[10]   Measurement of low-dose active pharmaceutical ingredient in a pharmaceutical blend using frequency-domain photon migration [J].
Pan, TS ;
Barber, D ;
Coffin-Beach, D ;
Sun, ZG ;
Sevick-Muraca, EM .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2004, 93 (03) :635-645