Effect of Cataract and Its Removal on Ganglion Cell Complex Thickness and Peripapillary Retinal Nerve Fiber Layer Thickness Measurements by Fourier-Domain Optical Coherence Tomography

被引:24
作者
Nakatani, Yusuke [1 ,2 ]
Higashide, Tomomi [1 ]
Ohkubo, Shinji [1 ]
Takeda, Hisashi [1 ]
Sugiyama, Kazuhisa [1 ]
机构
[1] Kanazawa Univ, Grad Sch Med Sci, Dept Ophthalmol & Visual Sci, Kanazawa, Ishikawa 9208641, Japan
[2] Publ Cent Hosp Matto Ishikawa, Dept Ophthalmol, Matto, Japan
关键词
spectral domain optical coherence tomography; ganglion cell complex; peripapillary retinal nerve fiber layer; cataract; signal strength index; segmentation error; MACULAR THICKNESS; SIGNAL STRENGTH; PHACOEMULSIFICATION SURGERY; IMAGE QUALITY; GLAUCOMA; SEGMENTATION; STRATUS; OCT;
D O I
10.1097/IJG.0b013e3182894a16
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To examine the effect of cataract on signal strength index (SSI) and thickness measurements of the ganglion cell complex (GCC) and peripapillary retinal nerve fiber layer (pRNFL) with the RTVue-100 Fourier-domain optical coherence tomography device.Method: GCC and pRNFL measurements were obtained preoperatively in 53 eyes of 53 patients, including 13 glaucoma patients and measurements were repeated postoperatively. Cataract degree was graded by the Lens Opacities Classification System III. Factors associated with segmentation error and with changes in SSI or average thickness of GCC and pRNFL were determined.Results: The prevalence and proportion of segmentation error were higher in GCC measurements compared with pRNFL measurements (prevalence: 28.3% vs. 5.6%, P<0.001; proportion: 5.9% vs. 1.3%, P=0.01). Multivariate analysis showed that segmentation error in GCC measurements was significantly associated with preoperative SSI and the degree of posterior subcapsular opacity. In eyes without segmentation error, postoperative SSI was significantly higher for GCC and pRNFL measurements, whereas postoperative thickness was slightly but significantly higher for all GCC and pRNFL parameters. Multivariate analysis indicated that preoperative SSI was highly correlated with SSI changes and that the presence of glaucoma and preoperative SSI were significantly correlated with average thickness changes of GCC and pRNFL, respectively.Conclusions: In eyes with cataract, segmentation error occurred more frequently in GCC measurements than in pRNFL measurements. After cataract surgery, all thickness parameters in GCC and pRNFL measurements increased slightly. Segmentation errors should be determined, especially in GCC measurements of eyes with cataract and low SSI.
引用
收藏
页码:447 / 455
页数:9
相关论文
共 28 条
[1]  
Anderson D R., 1999, Automated Static Perimetry, V2nd, P152
[2]   Optical coherence tomography assessment of retinal nerve fiber laver thickness changes after glaucoma surgery [J].
Aydin, A ;
Wollstein, G ;
Price, LL ;
Fujimoto, JG ;
Schuman, JS .
OPHTHALMOLOGY, 2003, 110 (08) :1506-1511
[3]   Effect of image quality on tissue thickness measurements obtained with spectral domain-optical coherence tomography [J].
Balasubramanian, Madhusudhanan ;
Bowd, Christopher ;
Vizzeri, Gianmarco ;
Weinreb, Robert N. ;
Zangwill, Linda M. .
OPTICS EXPRESS, 2009, 17 (05) :4019-4036
[4]   Macular Thickness Measured by Optical Coherence Tomography in a Healthy Population Before and After Uncomplicated Cataract Phacoemulsification Surgery [J].
Cagini, Carlo ;
Fiore, Tito ;
Iaccheri, Barbara ;
Piccinelli, Francesco ;
Ricci, Maria Antonietta ;
Fruttini, Daniela .
CURRENT EYE RESEARCH, 2009, 34 (12) :1036-1041
[5]   Relationship between retinal nerve fiber layer measurement and signal strength in optical coherence tomography [J].
Cheung, Carol Yim Lui ;
Leung, Christopher Kai Shun ;
Lin, Dusheung ;
Pang, Chi-Pui ;
Lam, Dennis Shun Chiu .
OPHTHALMOLOGY, 2008, 115 (08) :1347-1351
[6]   THE LENS OPACITIES CLASSIFICATION SYSTEM-III [J].
CHYLACK, LT ;
WOLFE, JK ;
SINGER, DM ;
LESKE, MC ;
BULLIMORE, MA ;
BAILEY, IL ;
FRIEND, J ;
MCCARTHY, D ;
WU, SY .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (06) :831-836
[7]   The effect of phacoemulsification cataract surgery on the measurement of retinal nerve fiber layer thickness using optical coherence tomography [J].
El-Ashry, Mohamed ;
Appaswamy, Shivashankar ;
Deokule, Sunil ;
Pagliarini, Sergio .
CURRENT EYE RESEARCH, 2006, 31 (05) :409-413
[8]   Reproducibility of Retinal Nerve Fiber Layer and Macular Thickness Measurement with the RTVue-100 Optical Coherence Tomograph [J].
Garas, Anita ;
Vargha, Peter ;
Hollo, Gabor .
OPHTHALMOLOGY, 2010, 117 (04) :738-746
[9]   Reproducibility of RTVue Retinal Nerve Fiber Layer Thickness and Optic Disc Measurements and Agreement with Stratus Optical Coherence Tomography Measurements [J].
Gonzalez-Garcia, Alberto O. ;
Vizzeri, Gianmarco ;
Bowd, Christopher ;
Medeiros, Felipe A. ;
Zangwill, Linda M. ;
Weinreb, Robert N. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (06) :1067-1074
[10]   Macular segmentation with optical coherence tomography [J].
Ishikawa, H ;
Stein, DM ;
Wollstein, G ;
Beaton, S ;
Fujimoto, JG ;
Schuman, JS .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (06) :2012-2017