Determination of MK-0431 in human plasma using high turbulence liquid chromatography online extraction and tandem mass spectrometry

被引:27
作者
Zeng, W [1 ]
Musson, DG [1 ]
Fisher, AL [1 ]
Wang, AQ [1 ]
机构
[1] Merck & Co Inc, Merck Res Labs, Dept Drug Metab, West Point, PA 19486 USA
关键词
D O I
10.1002/rcm.2426
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A robust and sensitive method using high turbulence liquid chromatography (HTLC) online extraction with tandem mass spectrometry (MS/MS) for the determination of MK-0431 in human plasma was developed and validated to support the clinical studies. This HTLC online extraction method eliminated the time-consuming offline sample extraction procedures and significantly increased productivity. A narrow bore large particle size reversed-phase column (Cyclone, 50 X 1.0 mm, 60 mu m) and a BDS Hypersil C18 column (30 X 2.1 mm, 3 mu m) were used as extraction and analytical columns, respectively. The linear dynamic range of the calibration curve was 0.5 to 1000 ng/mL. Intraday validation was conducted using five calibration curves prepared in five lots of human control plasma, and the intraday precision (RSD%) was from 2.4 to 9.0% and the accuracy was from 98.0 to 103% of the nominal value. The intraday precision (RSD%, n = 5) for plasma quality control (QC) samples varied from 2.0 to 5.3% and accuracy from 103 to 105% of the nominal value. The interday precision (RSD%) for 100 sets of plasma QC samples in 29 analytical runs varied from 6.3 to 9.0% and the accuracy from 98.8 to 104% of the nominal value. No significant difference was observed between the interday and intraday precision and accuracy of the QC samples. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:1169 / 1175
页数:7
相关论文
共 27 条
[1]  
[Anonymous], GUID IND BIOAN METH
[2]  
Ayrton J, 1997, RAPID COMMUN MASS SP, V11, P1953, DOI 10.1002/(SICI)1097-0231(199712)11:18<1953::AID-RCM102>3.0.CO
[3]  
2-Z
[4]  
Brignol N, 2000, RAPID COMMUN MASS SP, V14, P141, DOI 10.1002/(SICI)1097-0231(20000215)14:3&lt
[5]  
141::AID-RCM856&gt
[6]  
3.0.CO
[7]  
2-I
[8]   A parallel micro turbulent flow chromatography-tandem mass spectrometry method for the analysis of a pharmaceutical compound in plasma [J].
Chassaing, C ;
Stafford, H ;
Luckwell, J ;
Wright, A ;
Edgington, A .
CHROMATOGRAPHIA, 2005, 62 (1-2) :17-24
[9]  
Chassaing C, 2001, CHROMATOGRAPHIA, V53, P122
[10]   High turbulence liquid chromatography online extraction and tandem mass spectrometry for the simultaneous determination of suberoylanilide hydroxamic acid and its two metabolites in human serum [J].
Du, LH ;
Musson, DG ;
Wang, AQ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (13) :1779-1787