Volumetric depth peeling for medical image display

被引:2
作者
Borland, David [1 ]
Clarke, John P. [1 ]
Fielding, Julia R. [1 ]
Taylor, Russell M., II [1 ]
机构
[1] Univ N Carolina, Dept Comp Sci, Chapel Hill, NC 27599 USA
来源
VISUALIZATION AND DATA ANALYSIS 2006 | 2006年 / 6060卷
关键词
visualization in medicine; applications of volume graphics and volume visualization; view-dependent visualization; volume rendering;
D O I
10.1117/12.641497
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Volumetric depth peeling (VDP) is an extension to Volume rendering that enables display of otherwise Occluded features in Volume data sets. VDP decouples occlusion calculation from the volume rendering transfer function, enabling independent optimization of settings for rendering and Occlusion. The algorithm is flexible enough to handle Multiple regions occluding the object of interest, as well as object self-occlusion, and requires no pre-segmentation of the data set. VDP was developed as an improvement for virtual arthroscopy for the diagnosis of shoulder-joint trauma, and has been generalized for use in other simple and complex joints, and to enable non-invasive urology Studies. In virtual arthroscopy, the Surfaces in the joints often occlude each other, allowing limited viewpoints from which to evaluate these surfaces. In urology Studies. the physician would like to position the virtual camera Outside the kidney collecting system and see inside it. By rendering invisible all voxels between the observer's point of view and objects of interest, VDP enables viewing from unconstrained positions. In essence, VDP can be viewed as a technique for automatically defining an optimal data- and task-dependent clipping Surface. Radiologists using VDP display have been able to perform evaluations of pathologies more easily and more rapidly than with clinical arthroscopy, standard volume rendering, or standard MRI/CT slice viewing.
引用
收藏
页数:11
相关论文
共 39 条
[21]   CT arthrography and virtual arthroscopy in the diagnosis of the anterior cruciate ligament and meniscal abnormalities of the knee joint [J].
Lee, W ;
Kim, HS ;
Kim, SJ ;
Kim, HH ;
Chung, JW ;
Kang, HS ;
Hong, SH ;
Choi, JY .
KOREAN JOURNAL OF RADIOLOGY, 2004, 5 (01) :47-54
[22]   DISPLAY OF SURFACES FROM VOLUME DATA [J].
LEVOY, M .
IEEE COMPUTER GRAPHICS AND APPLICATIONS, 1988, 8 (03) :29-37
[23]   An efficient volume-rendering algorithm with an analytic approach [J].
Lin, CC ;
Ching, YT .
VISUAL COMPUTER, 1996, 12 (10) :515-526
[25]   Excretory phase CT urography for opacification of the urinary collecting system [J].
McNicholas, MMJ ;
Raptopoulos, VD ;
Schwartz, RK ;
Sheiman, RG ;
Zormpala, A ;
Prassopoulos, PK ;
Ernst, RD ;
Pearlman, JD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (05) :1261-1267
[26]   Multi-detector row CT urography: Comparison of strategies for depicting the normal urinary collecting system [J].
McTavish, JD ;
Jinzaki, M ;
Zou, KH ;
Nawfel, RD ;
Silverman, SG .
RADIOLOGY, 2002, 225 (03) :783-790
[27]   Depth-peeling for texture-based volume rendering [J].
Nagy, Z ;
Klein, R .
11TH PACIFIC CONFERENCE ON COMPUTER GRAPHICS AND APPLICATIONS, PROCEEDINGS, 2003, :429-433
[28]   Interactive ray tracing for isosurface rendering [J].
Parker, S ;
Shirley, P ;
Livnat, Y ;
Hansen, C ;
Sloan, PP .
VISUALIZATION '98, PROCEEDINGS, 1998, :233-+
[29]   Opacity-modulating triangular textures for irregular surfaces [J].
Rheingans, P .
VISUALIZATION '96, PROCEEDINGS, 1996, :219-+
[30]  
SAHIN, 2004, SKELETAL RADIOL, P9