Intra-session repeatability of lower limb muscles activation pattern during pedaling

被引:70
作者
Dorel, Sylvain [1 ]
Couturier, Antoine [1 ]
Hug, Francois [1 ,2 ]
机构
[1] Natl Inst Sports INSEP, Lab Biomech & Physiol, F-75012 Paris, France
[2] Nantes Atlantic Univ, Univ Nantes, Lab Motricity Interact Performance JE 2438, F-44000 Nantes, France
关键词
Triathletes; Reproducibility; Root mean square; Cycling; Training;
D O I
10.1016/j.jelekin.2007.03.002
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Assessment of intra-session repeatability of muscle activation pattern is of considerable relevance for research settings, especially when used to determine changes over time. However, the repeatability of lower limb muscles activation pattern during pedaling is not fully established. Thus, we tested the intra-session repeatability of the activation pattern of 10 lower limb muscles during a sub-maximal cycling exercise. Eleven triathletes participated to this study. The experimental session consisted in a reference sub-maximal cycling exercise (i.e. 150 W) performed before and after a 53-min simulated training session (mean power output = 200 +/- 12 W). Repeatability of EMG patterns was assessed in terms of muscle activity level (i.e. RMS of the mean pedaling cycle and burst) and muscle activation timing (i.e. onset and offset of the EMG burst) for the 10 following lower limb muscles: gluteus maximus (GMax), semimembranosus (SM), Biceps femoris (BF), vastus medialis (VM), rectus femoris (RF), vastus lateralis (VL), gastrocnemius medianus (GM) and lateralis (GL), soleus (SOL) and tibialis anterior (TA). No significant differences concerning the muscle activation level were found between test and retest for all the muscles investigated. Only VM, SOL and TA showed significant differences in muscle activation timing parameters. Whereas ICC and SEM values confirmed this weak repeatability, cross-correlation coefficients suggest a good repeatability of the activation timing parameters for all the studied muscles. Overall, the main finding of this work is the good repeatability of the EMG pattern during pedaling both in term of muscle activity level and muscle activation timing. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:857 / 865
页数:9
相关论文
共 33 条
  • [1] Bernshtein N. A., 1967, COORDINATION REGULAT
  • [2] INTEGRATED ELECTROMYOGRAM AND OXYGEN-UPTAKE DURING POSITIVE AND NEGATIVE WORK
    BIGLANDRITCHIE, B
    WOODS, JJ
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1976, 260 (02): : 267 - 277
  • [3] Currier D., 1990, ELEMENTS RES PHYS TH
  • [4] Reliability of EMG measurements for trunk muscles during maximal and sub-maximal voluntary isometric contractions in healthy controls and CLBP patients
    Dankaerts, W
    O'Sullivan, PB
    Burnett, AF
    Straker, LM
    Danneels, LA
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2004, 14 (03) : 333 - 342
  • [5] Between-days reliability of subjective and objective assessments of back extensor muscle fatigue in subjects without lower-back pain
    Dedering, Å
    Hjelmsäter, MRA
    Elfving, B
    Harms-Ringdahl, K
    Németh, G
    [J]. JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2000, 10 (03) : 151 - 158
  • [6] Muscular activity level during pedalling is not affected by crank inertial load
    Duc, S
    Villerius, V
    Bertucci, W
    Pernin, JN
    Grappe, F
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2005, 95 (2-3) : 260 - 264
  • [7] DUC S, 2006, J ELECTROMY IN PRESS, DOI DOI 10.1016/J.JELEKIN.2007.09.007
  • [8] Ericson M, 1986, Scand J Rehabil Med Suppl, V16, P1
  • [9] Repeatability of surface EMG variables in the sternocleidomastoid and anterior scalene muscles
    Falla, D
    Dall'Alba, P
    Rainoldi, A
    Merletti, R
    Jull, G
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2002, 87 (06) : 542 - 549
  • [10] The extraction of neural strategies from the surface EMG
    Farina, D
    Merletti, R
    Enoka, RM
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2004, 96 (04) : 1486 - 1495