Periprosthetic supracondylar femoral fractures following knee arthroplasty: a biomechanical comparison of four methods of fixation

被引:32
作者
Maekinen, Tatu J. [1 ]
Dhotar, Herman S. [1 ]
Fichman, Simcha G. [1 ]
Gunton, Matthew J. [1 ]
Woodside, Mitchell [2 ]
Safir, Oleg [1 ]
Backstein, David [1 ]
Willett, Thomas L. [2 ]
Kuzyk, Paul R. T. [1 ]
机构
[1] Univ Toronto, Mt Sinai Hosp, Div Orthopaed Surg, Toronto, ON M5G 1X5, Canada
[2] Univ Toronto, Inst Biomat & BioMed Engn, Mat Sci & Engn, Toronto, ON M5G 1X5, Canada
关键词
Periprosthetic fracture; Total knee arthroplasty; Locked plate; Intramedullary nail; Allograft; DISTAL FEMUR FRACTURES; INTRAMEDULLARY FIBULAR ALLOGRAFT; LOCKING PLATE FIXATION; NAIL; REPLACEMENT; PROSTHESIS; MANAGEMENT; REDUCTION; SCREWS;
D O I
10.1007/s00264-015-2764-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The aim of this study was to determine the biomechanical properties of four fixation options for periprosthetic supracondylar femoral fractures. Methods Fourth-generation composite femurs were implanted with a posterior-stabilizing femoral component of total knee arthroplasty. All femurs were osteotomized to produce a AO/OTA 33-A3 fracture pattern and four different constructs were tested: (1) non-locking plate; (2) polyaxial locking plate; (3) intramedullary fibular strut allograft with polyaxial locking plate; (4) retrograde intramedullary nail. The composite femurs underwent non-destructive tests to determine construct stiffness in axial and torsional cyclic loading. The final testing consisted of quasi-static axial loading until failure. Results Under cyclic torsional loading, the retrograde intramedullary nail was less stiff than non-locking plate, polyaxial locking plate and intramedullary fibular strut allograft with polyaxial locking plate (p = 0.046). No differences were detected in cyclic axial loading between the different constructs. During quasi-static axial loading to failure, the intramedullary nail achieved the highest axial stiffness while the non-locking plate showed the lowest (p = 0.036). Conclusions The intramedullary fibular strut allograft with polyaxial locking plate did not prove to be significantly better to the polyaxial locking plate only in a periprosthetic distal femur fracture model.
引用
收藏
页码:1737 / 1742
页数:6
相关论文
共 27 条
[1]   The biomechanics of three different fracture fixation implants for distal femur repair in the presence of a tumor-like defect [J].
Ahmadi, Shahryar ;
Shah, Suraj ;
Wunder, Jay S. ;
Schemitsch, Emil H. ;
Ferguson, Peter C. ;
Zdero, Rad .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H1) :78-86
[2]   Intramedullary Allograft Fibula as a Reduction and Fixation Tool for Treatment of Complex Proximal Humerus Fractures With Diaphyseal Extension [J].
Berkes, Marschall B. ;
Little, Milton T. M. ;
Lazaro, Lionel E. ;
Cymerman, Rachel M. ;
Pardee, Nadine C. ;
Helfet, David L. ;
Dines, Joshua S. ;
Lorich, Dean G. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2014, 28 (03) :E56-E64
[3]   Finite element comparison of retrograde intramedullary nailing and locking plate fixation with/without an intramedullary allograft for distal femur fracture following total knee arthroplasty [J].
Chen, Shih-Hao ;
Chiang, Ming-Chieh ;
Hung, Ching-Hua ;
Lin, Shang-Chih ;
Chang, Hsiao-Wei .
KNEE, 2014, 21 (01) :224-231
[4]  
Davison Brian L, 2003, Am J Orthop (Belle Mead NJ), V32, P27
[5]   Periprosthetic Fractures: Epidemiology and Future Projections [J].
Della Rocca, Gregory J. ;
Leung, Kwok Sui ;
Pape, Hans-Christoph .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2011, 25 :S66-S70
[6]  
Ebraheim Nabil A, 2002, Am J Orthop (Belle Mead NJ), V31, P270
[7]   Revision Internal Fixation and Nonvascular Fibular Graft for Femoral Neck Nonunion [J].
Elgafy, Hossein ;
Ebraheim, Nabil A. ;
Gregory, Harold .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 70 (01) :169-173
[8]   Midterm results of treatment with a retrograde nail for supracondylar periprosthetic fractures of the femur following total knee arthroplasty [J].
Gliatis, J ;
Megas, P ;
Panagiotopoulos, E ;
Lambiris, E .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2005, 19 (03) :164-170
[9]   Mono- versus polyaxial locking plates in distal femur fractures: a prospective randomized multicentre clinical trial [J].
Hanschen, Marc ;
Aschenbrenner, Ina M. ;
Fehske, Kai ;
Kirchhoff, Sonja ;
Keil, Leonhard ;
Holzapfel, Boris M. ;
Winkler, Sebastian ;
Fuechtmeier, Bernd ;
Neugebauer, Rainer ;
Luehrs, Sven ;
Liener, Ulrich ;
Biberthaler, Peter .
INTERNATIONAL ORTHOPAEDICS, 2014, 38 (04) :857-863
[10]   Treatment of acute distal femur fractures above a total knee arthroplasty -: Systematic review of 415 cases (1981-2006) [J].
Herrera, Diego A. ;
Kregor, Philip J. ;
Cole, Peter A. ;
Levy, Bruce A. ;
Jonsson, Anders ;
Zlowodzki, Michael .
ACTA ORTHOPAEDICA, 2008, 79 (01) :22-27