The use of a bioresorbable nano-crystalline hydroxyapatite paste in acetabular bone impaction grafting

被引:66
作者
Arts, JJC [1 ]
Verdonschot, N [1 ]
Schreurs, BW [1 ]
Buma, P [1 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Orthopaed, Orthopaed Res Lab, NL-6500 HB Nijmegen, Netherlands
关键词
biocompatibility; bone graft; hydroxyapatite; joint replacement; nano-composite; osseointegration;
D O I
10.1016/j.biomaterials.2005.07.024
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Calcium phosphates such as TCP-HA granules are considered promising bone graft substitutes. In the future, they may completely replace allograft bone for impaction grafting procedures. Mechanically, acetabular reconstructions with TCP-HA granules show high stability, however this is partly caused by excessive cement penetration, which is unfavourable from a biological perspective. It has been hypothesised that mixtures of morselised cancellous bone grafts (MCB) and/or TCP-HA granules with a nanocrystalline hydroxyapatite paste (Ostim (R)) may reduce cement penetration while maintaining adequate implant stability and biocompatibility of the graft mixture. To investigate this hypothesis, destructive lever-out tests and in vivo animal test were performed with various combinations of materials. Mechanically, the addition of 10% Ostim to mixtures of MCB and/or TCP-HA granules reduced cement penetration and resulted in a mechanical stability comparable to pure allograft (the current gold standard). Biologically, the application of Ostim with MCB or TCP-HA granules did not hamper the biocompatibility of the materials. Ostim was mostly osseous-integrated with MCB or TCP-HA granules after 8 weeks. Also, non-osseous-integrated Ostim remnants were observed. In tartrate resistant acid phosphatase stained sections, these few non-osseous integrated Ostim remnants were actively being resorbed by osteoclasts. In conclusion, Ostim HA-paste could be a valuable addition when TCP-HA ceramic granules are being used for acetabular bone impaction grafting procedures. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1110 / 1118
页数:9
相关论文
共 23 条
  • [11] KILIAN O, 2002, BIOMATERIALIEN, V3, P126
  • [12] KILIAN O, 2002, BIOMATERIALIEN, V3, P70
  • [13] LeGeros RZ, 2002, CLIN ORTHOP RELAT R, P81
  • [14] Ornstein E, 2002, ACTA ORTHOP SCAND, V73, P3
  • [15] Schnettler R, 2002, TISSUE ENGINEERING AND BIODEGRADABLE EQUIVALENTS: SCIENTIFIC AND CLINICAL APPLICATIONS, P401
  • [16] Acetabular revision with impacted morsellised cancellous bone grafting and a cemented cup - A 15-to 20-year follow-up
    Schreurs, BW
    Bolder, SBT
    Gardeniers, JWM
    Verdonschot, N
    Slooff, TJJH
    Veth, RPH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (04): : 492 - 497
  • [17] Schreurs BW, 2001, CLIN ORTHOP RELAT R, P202
  • [18] SEIDEL P, 2002, 17 C BIOM BARC SPAIN
  • [19] BONE-GRAFTING IN TOTAL HIP-REPLACEMENT FOR ACETABULAR PROTRUSION
    SLOOFF, TJJH
    HUISKES, R
    VANHORN, J
    LEMMENS, AJ
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (06): : 593 - 596
  • [20] A thorough physicochemical characterisation of 14 calcium phosphate-based bone substitution materials in comparison to natural bone
    Tadic, D
    Epple, M
    [J]. BIOMATERIALS, 2004, 25 (06) : 987 - 994