The long-stroke MROI vacuum delay lines: from concept to production

被引:3
作者
Haniff, Christopher A. [1 ]
Boysen, Roger C. [1 ]
Buscher, David F. [1 ]
Fisher, Martin [1 ]
Seneta, Eugene B. [1 ]
Sun, Xiaowei [1 ]
Wilson, Donald M. A. [1 ]
Young, John S. [1 ]
Santoro, Fernando [2 ]
机构
[1] Univ Cambridge, Cavendish Lab, JJ Thomson Ave, Cambridge CB3 0HE, England
[2] New Mexico Inst Min & Technol, Magdalena Ridge Observ, Socorro, NM 87801 USA
来源
OPTICAL AND INFRARED INTERFEROMETRY | 2008年 / 7013卷
关键词
Delay lines; stellar interferometry;
D O I
10.1117/12.789761
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
We report on test results on the delay line system for the MRO Interferometer, currently under construction in Cambridge, UK. The delay lines are designed to provide 380 metres of vacuum path delay in a single stage, offering rapid star-to-star slews. high throughput and high transmitted wavefront quality. Details of the final design adopted for these delay lines are presented, together with lessons learnt, from successful performance tests of the full-scale prototype trolley in a 20-metre long vacuum test, rig. Delivery of the first production trolley is expected in New Mexico in early 2009.