Non-specific Adsorption of Crude Cell Lysate on Surface Plasmon Resonance Sensors

被引:21
|
作者
Aube, Alexandra [1 ]
Breault-Turcot, Julien [1 ]
Chaurand, Pierre [1 ]
Pelletier, Joelle N. [1 ,2 ,3 ]
Masson, Jean-Francois [1 ,4 ]
机构
[1] Univ Montreal, Dept Chim, Montreal, PQ H3C 3J7, Canada
[2] Univ Montreal, Dept Biochim, Montreal, PQ H3C 3J7, Canada
[3] Univ Laval, PROTEO, Quebec Network Res Prot Struct Funct & Engn, Quebec City, PQ G1V 0A6, Canada
[4] McGill Univ, CSACS, Montreal, PQ H3A 2K6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
SELF-ASSEMBLED MONOLAYERS; LABEL-FREE; MASS-SPECTROMETRY; LIPID-BILAYER; BIOMARKER; PROTEINS; CARCINOMA; RESIST;
D O I
10.1021/la401837y
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Non-specific adsorption of the molecular components of biofluids is ubiquitous in the area of biosensing technologies, severely limiting the use of biosensors in real-world applications. The surface chemistries developed to prevent non-specific adsorption of crude serum are not necessarily suited for sensing in other biosamples. In particular, the diagnostic potential of differential expression of proteins in tissues makes cell lysate attractive for disease diagnostics using solid biopsies. However, crude cell lysate poses a significant challenge for surface chemistries because of a large concentration of highly adherent lipids. Contrary to the nonspecific adsorption in crude serum being suppressed by hydrophilic surfaces, the surface plasmon resonance (SPR) analysis of serine-, aspartic-acid-, histidine-, leucine-, and phenylalanine-based peptide monolayers revealed that hydrophobic and positively charged peptides decreased non-specific adsorption when using lysate from HEK 293FT cells. A polyethylene glycol (PEG) monolayer resulted in 2-fold greater fouling than the best peptide [3-MPA-(His)(2)(Leu)(2)(Phe)(2)-OH] under the same conditions. Matrix-assisted laser desorption ionization tandem time-of-flight mass spectrometry (MALDI-TOF/TOF MS) analysis of the adsorbate from cell lysate confirmed that lipids are the main source of non-specific adsorption. Importantly, the mass spectrometry (MS) study revealed that both the number of lipids identified and their intensity decreased with decreasing non-specific adsorption. A peptide monolayer thus provides an efficient mean to suppress non-specific adsorption from this human cell lysate.
引用
收藏
页码:10141 / 10148
页数:8
相关论文
共 50 条
  • [1] Detection of embryonic stem cell lysate biomarkers by surface plasmon resonance with reduced nonspecific adsorption
    Tyagi, Deependra
    Perez, Javier Batista
    Nand, Amita
    Cheng Zhiqiang
    Wang, Peizhe
    Na, Jie
    Zhu, Jingsong
    ANALYTICAL BIOCHEMISTRY, 2015, 471 : 29 - 37
  • [2] Promising Solutions to Address the Non-Specific Adsorption in Biosensors Based on Coupled Electrochemical-Surface Plasmon Resonance Detection
    Vasilescu, Alina
    Gaspar, Szilveszter
    Gheorghiu, Mihaela
    Polonschii, Cristina
    Banciu, Roberta Maria
    David, Sorin
    Gheorghiu, Eugen
    Marty, Jean-Louis
    CHEMOSENSORS, 2025, 13 (03)
  • [3] Localized Surface Plasmon Resonance Sensors
    Mayer, Kathryn M.
    Hafner, Jason H.
    CHEMICAL REVIEWS, 2011, 111 (06) : 3828 - 3857
  • [4] Inhibition of non-specific protein adsorption on PMMA surface: The role of surface modification
    Xian, Zhaokun
    Dai, Peng
    Su, Wenyun
    Xing, Dong
    Sun, Cuimin
    You, Hui
    JOURNAL OF SAUDI CHEMICAL SOCIETY, 2023, 27 (06)
  • [5] Methods of reducing non-specific adsorption in microfluidic biosensors
    Choi, Seokheun
    Chae, Junseok
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2010, 20 (07)
  • [6] Design and mechanisms of antifouling materials for surface plasmon resonance sensors
    Liu, Boshi
    Liu, Xia
    Shi, Se
    Huang, Renliang
    Su, Rongxin
    Qi, Wei
    He, Zhimin
    ACTA BIOMATERIALIA, 2016, 40 : 100 - 118
  • [7] Surface Plasmon Resonance Imaging Sensors: A Review
    Wong, Chi Lok
    Olivo, Malini
    PLASMONICS, 2014, 9 (04) : 809 - 824
  • [8] Polyglycerol based coatings to reduce non-specific protein adsorption in sample vials and on SPR sensors
    Becherer, Tobias
    Grunewald, Christian
    Engelschalt, Vivienne
    Multhaup, Gerhard
    Risse, Thomas
    Haag, Rainer
    ANALYTICA CHIMICA ACTA, 2015, 867 : 47 - 55
  • [9] Non-Specific Adsorption Reduction Methods in Biosensing
    Lichtenberg, Jessanne Y.
    Ling, Yue
    Kim, Seunghyun
    SENSORS, 2019, 19 (11)
  • [10] Sensing using localised surface plasmon resonance sensors
    Szunerits, Sabine
    Boukherroub, Rabah
    CHEMICAL COMMUNICATIONS, 2012, 48 (72) : 8999 - 9010