Short-circuit analysis of a doubly fed induction generator wind turbine with direct current chopper?protection

被引:8
|
作者
Sulla, F. [1 ]
Svensson, J. [1 ]
Samuelsson, O. [1 ]
机构
[1] Lund Univ, IEA, S-22100 Lund, Sweden
关键词
DFIG; short-circuit current; grid fault ride through; chopper; crowbar;
D O I
10.1002/we.524
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Modern doubly fed induction generator (DFIG) wind turbines can ride through a symmetrical fault in the network by using a chopper protection on the direct current (DC) link without triggering a crowbar protection. A novel method to model the DC link system of such wind turbines as an equivalent resistance during symmetrical faults is presented in this paper. The method allows looking at the DFIG with chopper protection as to one with an equivalent crowbar protection and, hence, to apply to the former type of DFIG short-circuit calculation methods developed for a DFIG with crowbar protection. This may be a valid help in short-circuit calculations, for example, for protection settings. It also allows simulating for short-circuit studies a DFIG with chopper protection, often not available in a standard power system simulation software, by using an equivalent DFIG with crowbar protection, which is a standard model in power system simulation software. The results for the short-circuit current obtained through the proposed method are compared with simulations of a detailed model of a DFIG with chopper protection under different conditions, which showed good agreement. It is also shown that the DFIG with chopper protection delivers lower short-circuit current than a DFIG with standard crowbar protection, especially for low initial loading. Copyright (C) 2011 John Wiley & Sons, Ltd.
引用
收藏
页码:37 / 49
页数:13
相关论文
共 50 条
  • [1] Analysis of short circuit current of wind turbine - Doubly fed induction generator
    Li, D. D.
    2006 1st IEEE Conference on Industrial Electronics and Applications, Vols 1-3, 2006, : 920 - 924
  • [2] Analysis of short circuit current of wind turbine - Doubly fed induction generator
    Li, D. D.
    ICIEA 2006: 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, PROCEEDINGS, 2006, : 1082 - 1086
  • [3] Short-circuit current of wind turbines with doubly fed induction generator
    Morren, Johan
    de Haan, Sjoerd W. H.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) : 174 - 180
  • [4] Symmetrical Short Circuit Current Characteristics of Doubly Fed Induction Generator Wind Turbine with Crowbar Protection
    Zhai Jiajun
    Zhang Buhan
    Wang Kui
    Shao Wen
    Mao Chengxiong
    RENEWABLE AND SUSTAINABLE ENERGY II, PTS 1-4, 2012, 512-515 : 782 - 787
  • [5] Short-Circuit Current Calculation and Harmonic Characteristic Analysis for a Doubly-Fed Induction Generator Wind Turbine under Converter Control
    Li, Jing
    Zheng, Tao
    Wang, Zengping
    ENERGIES, 2018, 11 (09)
  • [6] Research on Short-Circuit Voltage of Wind Turbines with Doubly Fed Induction Generator
    Yue, Gaili
    Chen, Sha
    Ma, Cunchao
    INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE AND APPLICATION ENGINEERING (CSAE), 2017, 190 : 358 - 366
  • [7] Short-circuit current characteristic of doubly fed induction generator considering crowbar protection insertion time
    Wei, Z. (wzphd001@126.com), 1600, Automation of Electric Power Systems Press (38):
  • [8] Analysis of three-phase short-circuit current characteristics of doubly fed induction generator
    Fan X.
    Sun S.
    Sun D.
    Hai S.
    Wang Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (18): : 38 - 48
  • [9] Comparison of Short-circuit Current Contribution of Doubly-Fed Induction Generator based Wind Turbines and Synchronous Generator
    Elnaggar, A. K.
    Rueda, J. L.
    Erlich, I.
    2013 IEEE GRENOBLE POWERTECH (POWERTECH), 2013,
  • [10] Short-Circuit Current of a Doubly-Fed Induction Generator: Analytical Solution and Insights
    Marmolejo, Alejandro
    Palazzo, Mirko
    Delfanti, Maurizio
    2014 IEEE CONFERENCE ON ENERGY CONVERSION (CENCON), 2014, : 128 - 133