Pilot investigation of a novel testing strategy for bleeding in ventricular assist device recipients

被引:12
作者
Joyce, David [1 ]
Crow, Sheri [2 ]
Li, Zhuo [3 ]
Joyce, Lyle [4 ]
Milano, Carmelo [5 ]
Rogers, Joseph [6 ]
Villamizar-Ortiz, Nestor [7 ]
Chen, Dong [8 ]
机构
[1] HlthE Care Syst Inc, Dept Cardiothorac Surg, St Paul, MN USA
[2] Mayo Clin, Div Pediat Crit Care Med, Rochester, MN USA
[3] Mayo Clin, Div Biomed Stat & Informat, Rochester, MN USA
[4] Mayo Clin, Div Cardiac Surg, Rochester, MN USA
[5] Duke Univ, Div Cardiothorac Surg, Durham, NC USA
[6] Duke Univ, Dept Cardiol, Durham, NC USA
[7] Duke Univ, Dept Surg, Durham, NC USA
[8] Mayo Clin, Dept Lab Med & Pathol, Rochester, MN USA
关键词
high molecular weight von Willebrand factor multimers; left ventricular assist device; axial flow; heart failure; bleeding complications; VON-WILLEBRAND-FACTOR; FACTOR ACTIVITY ASSAY; DISEASE; TRANSPLANTATION; DIAGNOSIS; PULSATILE;
D O I
10.1016/j.healun.2012.02.032
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
PURPOSE: A universal loss of von Willebrand factor (vWF) high-molecular-weight multimers (HMWM) has been demonstrated in continuous-flow left ventricular assist device (HeartMate II) recipients. However, no reliable clinical or laboratory predictors for an increased bleeding tendency in this patient population have been identified. This study evaluated the ability of a new automated latex particle-enhanced immunoturbidimetric vWF activity assay (ALPEIVA) to predict non-surgical bleeding risk in HeartMate II recipients. METHODS: As part of a prospective multicenter trial, pre-surgical, 7-day, and 30-day post-implantation blood samples were collected from 24 patients. ALPEIVA-assessed vWF activities were compared among patients with and without non-surgical bleeding complications after HeartMate II implantation. Additional laboratory testing included factor VIII activity (FVIII:C), vWF antigen (vWFAg), vWF ristocetin cofactor activity (vWF:RCo), and vWF multimer analysis. RESULTS: All 24 patients had HMWM losses after HeartMate II implantation. Five patients (20%) developed non-surgical bleeding complications between 14 days and 6 months after HeartMate II implantation. Among various laboratory variables, only mean ALPEIVA/vWFAg ratios (referred to as the "bleeding ratio") were significantly lower in patients with clinically relevant bleeding (mean, 0.70 +/- 0.06) compared with patients without bleeding (mean, 0.78 +/- 0.09; p = 0.02) when measured at 30 days. CONCLUSIONS: The post-surgical bleeding ratio could potentially predict non-surgical bleeding risk and guide anti-platelet and anti-coagulation strategies in HeartMate II recipients. J Heart Lung Transplant 2012;31:750-6 (C) 2012 International Society for Heart and Lung Transplantation. All rights reserved.
引用
收藏
页码:750 / 756
页数:7
相关论文
共 21 条
[1]  
CANNEGIETER SC, 1994, NEW ENGL J MED, V330, P507
[2]  
Cannegieter SC, 1994, NEW ENGL J MED, V330, P508
[3]  
CHAND S, 1986, THROMB HAEMOSTASIS, V55, P318
[4]  
Chen D, 2008, J THROMB HAEMOST, V6, P323, DOI 10.1111/j.1538-7836.2008.02845.x
[5]   Validation of an automated latex particle-enhanced immunoturbidimetric von Willebrand factor activity assay [J].
Chen, D. ;
Tange, J. I. ;
Meyers, B. J. ;
Pruthi, R. K. ;
Nichols, W. L. ;
Heit, J. A. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 (10) :1993-2002
[6]   Acquired von Willebrand Syndrome in Continuous-Flow Ventricular Assist Device Recipients [J].
Crow, Sheri ;
Chen, Dong ;
Milano, Carmelo ;
Thomas, William ;
Joyce, Lyle ;
Piacentino, Valentino, III ;
Sharma, Riti ;
Wu, Jogin ;
Arepally, Gowthami ;
Bowles, Dawn ;
Rogers, Joseph ;
Villamizar-Ortiz, Nestor .
ANNALS OF THORACIC SURGERY, 2010, 90 (04) :1263-1269
[7]   Comparative Analysis of von Willebrand Factor Profiles in Pulsatile and Continuous Left Ventricular Assist Device Recipients [J].
Crow, Sheri ;
Milano, Carmelo ;
Joyce, Lyle ;
Chen, Dong ;
Arepally, Gowthami ;
Bowles, Dawn ;
Thomas, William ;
Ortiz, Nestor Villamizar .
ASAIO JOURNAL, 2010, 56 (05) :441-445
[8]   Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices [J].
Crow, Sheri ;
John, Ranjit ;
Boyle, Andrew ;
Shumway, Sara ;
Liao, Kenneth ;
Colvin-Adams, Monica ;
Toninato, Carol ;
Missov, Emil ;
Pritzker, Marc ;
Martin, Cindy ;
Garry, Daniel ;
Thomas, William ;
Joyce, Lyle .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (01) :208-215
[9]  
De Vleeschamer A, 2006, BLOOD COAGUL FIBRIN, V17, P353
[10]   Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease [J].
Geisen, Ulrich ;
Heilmann, Claudia ;
Beyersdorf, Friedhelm ;
Benk, Christoph ;
Berchtold-Herz, Michael ;
Schlensak, Christian ;
Budde, Ulrich ;
Zieger, Barbara .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 33 (04) :679-684