Improved walking ability with wearable robot-assisted training in patients suffering chronic stroke

被引:21
作者
Li, Lifang [1 ,2 ]
Ding, Li [3 ]
Chen, Na [1 ,2 ]
Mao, Yurong [1 ,2 ]
Huang, Dongfeng [1 ,2 ]
Li, Le [1 ,2 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 1, Dept Rehabil Med, Guangzhou 510080, Guangdong, Peoples R China
[2] Guangdong Prov Res Ctr Rehabil Med & Translat Tec, Guangzhou 510080, Guangdong, Peoples R China
[3] Fudan Univ, Huashan Hosp, Dept Rehabil, Shanghai 200040, Peoples R China
基金
中国国家自然科学基金;
关键词
Chronic stroke; robotic leg orthosis; gait performance; EMG; FUGL-MEYER ASSESSMENT; GAIT SPEED; RECOVERY; BALANCE; HIP; RELIABILITY; PERFORMANCE; PATTERNS; PEOPLE; LIMB;
D O I
10.3233/BME-151320
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Wearable robotic devices provide safe and intensive rehabilitation, enabling repeated motions for motor function recovery in stroke patients. The aim of this small case series was to demonstrate the training effects of a three-week robotic leg orthosis, and to investigate possible mechanisms of the sensory-motor alterations and improvements by using gait analysis and EMG. Three survivors of chronic strokes participated in robot-assisted gait therapy for three weeks. EMG signals from the rectus femoris (RF), tibialis anterior (TA), biceps femoris (BF), and medial gastrocnemius (MG), as well as kinetics and kinematics data of the lower limb, were recorded before and after the training. The normalized root mean squared (RMS) values of the muscles, the joint moments, joint angles, and the results of two clinical scales (Berg Balance scale, BBS, and the lower extremity subscale of Fugl-Meyer assessment, LE-FMA) were used for analysis. All participants experienced improved balance and functional performances and increased BBS and LE-FMA scores. The EMG results showed there was an increase of the normalized RMS values of the MG and BF on the affected side. Additionally, EMG activities of the agonist and antagonist pair (i.e. RF and BF) appeared to return to similar levels after training. The peak moment of hip flexor, knee extensor, and plantar flexor, which all contributed to push-off power, were found to have increased after training. In summary, the three-week training period using the wearable RLO improved the three participants' gait performance by regaining push-off power and improved muscle activation and walking speed.
引用
收藏
页码:S329 / S340
页数:12
相关论文
共 32 条
[1]   Step length asymmetry is representative of compensatory mechanisms used in post-stroke hemiparetic walking [J].
Allen, Jessica L. ;
Kautz, Steven A. ;
Neptune, Richard R. .
GAIT & POSTURE, 2011, 33 (04) :538-543
[2]   The Accuracy of Individual Berg Balance Scale Items Compared with the Total Berg Score for Classifying People with Chronic Stroke According to Fall History [J].
Alzayer, Lamia ;
Beninato, Marianne ;
Portney, Leslie G. .
JOURNAL OF NEUROLOGIC PHYSICAL THERAPY, 2009, 33 (03) :136-143
[3]   Understanding Motor Impairment in the Paretic Lower Limb After a Stroke: A Review of the Literature [J].
Arene, N. ;
Hidler, J. .
TOPICS IN STROKE REHABILITATION, 2009, 16 (05) :346-356
[4]   Relationship between step length asymmetry and walking performance in subjects with chronic hemiparesis [J].
Balasubramanian, Chitralakshmi K. ;
Bowden, Mark G. ;
Neptune, Richard R. ;
Kautz, Steven A. .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2007, 88 (01) :43-49
[5]  
BERG KO, 1992, CAN J PUBLIC HEALTH, V83, pS7
[6]  
Bertoldo A, 2014, J NEUROENG REHABIL, V11, P53
[7]   Patterns of locomotor drive to motoneurons and last-order interneurons: Clues to the structure of the CPG [J].
Burke, RE ;
Degtyarenko, AM ;
Simon, ES .
JOURNAL OF NEUROPHYSIOLOGY, 2001, 86 (01) :447-462
[8]   Mobility training using a bionic knee orthosis in patients in a post-stroke chronic state: A case series [J].
Byl N.N. .
Journal of Medical Case Reports, 6 (1)
[9]   A method to differentiate the causes of stiff-knee gait in stroke patients [J].
Campanini, I. ;
Merlo, A. ;
Damiano, B. .
GAIT & POSTURE, 2013, 38 (02) :165-169
[10]  
Chan C., 2014, BRIT J SPORT MED, V48, P578