Quantitative simultaneous 99mTc/123I cardiac SPECT using MC-JOSEM

被引:19
作者
Ouyang, Jinsong [1 ]
Zhu, Xuping
Trott, Cathryn M.
El Fakhri, Georges
机构
[1] Massachusetts Gen Hosp, Div Nucl Med & Mol Imaging, Boston, MA 02114 USA
关键词
cardiology; expectation-maximisation algorithm; image reconstruction; iodine compounds; iterative methods; medical image processing; Monte Carlo methods; muscle; organic compounds; phantoms; single photon emission computed tomography; technetium compounds; ACUTE MYOCARDIAL-INFARCTION; HEART-DISEASE; BRAIN SPECT; SIMULATION; SCATTER; VALIDATION;
D O I
10.1118/1.3063544
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Simultaneous rest Tc-99m-Sestamibi/I-123-BMIPP cardiac SPECT imaging has the potential to replace current clinical Tc-99m-Sestamibi rest/stress imaging and therefore has great potential in the case of patients with chest pain presenting to the emergency department. Separation of images of these two radionuclides is difficult, however, because their emission energies are close. The authors previously developed a fast Monte Carlo (MC)-based joint ordered-subset expectation maximization (JOSEM) iterative reconstruction algorithm (MC-JOSEM), which simultaneously compensates for scatter and cross talk as well as detector response within the reconstruction algorithm. In this work, the authors evaluated the performance of MC-JOSEM in a realistic population of Tc-99m/I-123 studies using cardiac phantom data on a Siemens e.cam system using a standard cardiac protocol. The authors also compared the performance of MC-JOSEM for estimation tasks to that of two other methods: standard OSEM using photopeak energy windows without scatter correction (NSC-OSEM) and standard OSEM using a Compton-scatter energy window for scatter correction (SC-OSEM). For each radionuclide the authors separately acquired high-count projections of radioactivity in the myocardium wall, liver, and soft tissue background compartments of a water-filled torso phantom, and they generated synthetic projections of various dual-radionuclide activity distributions. Images of different combinations of myocardium wall/background activity concentration ratios for each radionuclide were reconstructed by NSC-OSEM, SC-OSEM, and MC-JOSEM. For activity estimation in the myocardium wall, MC-JOSEM always produced the best relative bias and relative standard deviation compared with NSC-OSEM and SC-OSEM for all the activity combinations. On average, the relative biases after 100 iterations were 8.1% for Tc-99m and 3.7% for I-123 with MC-JOSEM, 39.4% for Tc-99m and 23.7% for I-123 with NSC-OSEM, and 20.9% for Tc-99m with SC-OSEM. The relative standard deviations after 30 iterations were 0.7% for Tc-99m and 1.0% for I-123 with MC-JOSEM, as compared to 1.1% for Tc-99m and 1.2% for I-123 with NSC-OSEM and 1.3% for Tc-99m with SC-OSEM. Finally, the authors compared the relative standard deviation after 30 iterations with the minimum theoretical variance on activity estimation, the Cramer-Rao lower bound (CRB), and with the biased CRB. The measured precision was larger than the biased bound values by factors of 2-4, suggesting that further improvement could be made to the method.
引用
收藏
页码:602 / 611
页数:10
相关论文
共 18 条
[1]   Efficient simulation of SPECT down-scatter including photon interactions with crystal and lead [J].
de Jong, HWAM ;
Wang, WT ;
Frey, EC ;
Viergever, MA ;
Beekman, FJ .
MEDICAL PHYSICS, 2002, 29 (04) :550-560
[2]   Rapid SPECT simulation of downscatter in non-uniform media [J].
de Jong, HWAM ;
Beekman, FJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (03) :621-635
[3]   Acceleration of Monte Carlo SPECT simulation using convolution-based forced detection [J].
de Jong, HWAM ;
Slijpen, ETP ;
Beekman, FJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (01) :58-64
[4]   DEVELOPMENT AND VALIDATION OF A MONTE-CARLO SIMULATION OF PHOTON TRANSPORT IN AN ANGER CAMERA [J].
DEVRIES, DJ ;
MOORE, SC ;
ZIMMERMAN, RE ;
MUELLER, SP ;
FRIEDLAND, B ;
LANZA, RC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (04) :430-438
[5]   Quantitative simultaneous 99mTc-ECD/123I-FP-CIT SPECT in Parkinson's disease and multiple system atrophy [J].
El Fakhri, G ;
Habert, MO ;
Maksud, P ;
Kas, A ;
Malek, Z ;
Kijewski, MF ;
Lacomblez, L .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 (01) :87-92
[6]   Quantitative simultaneous 99mTc/123I SPECT:: Design study and validation with Monte Carlo simulations and physical acquisitions [J].
El Fakhri, G ;
Maksud, P ;
Kijewski, MF ;
Zimmerman, RE ;
Moore, SC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) :2315-2321
[7]  
El Fakhri G, 2001, J NUCL MED, V42, P300
[8]   Scatter and cross-talk corrections in simultaneous Tc-99m/I-123 brain SPECT using constrained factor analysis and artificial neural networks [J].
El Fakhri, G ;
Maksud, P ;
Kijewski, MF ;
Habert, MO ;
Todd-Pokropek, A ;
Aurengo, A ;
Moore, SC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) :1573-1580
[9]   Serial alterations and prognostic implications of myocardial perfusion and fatty acid metabolism in patients with acute myocardial infarction [J].
Hashimoto, Akiyoshi ;
Nakata, Tomoaki ;
Tamaki, Nagara ;
Kobayashi, Takeshi ;
Matsuki, Takayuki ;
Shogase, Takashi ;
Furudate, Masayori .
CIRCULATION JOURNAL, 2006, 70 (11) :1466-1474
[10]  
Kitagawa K, 2002, J NUCL MED, V43, P1286