Influencing parameters on measurement accuracy in dynamic mechanical analysis of thermoplastic polymers and their composites

被引:17
作者
Schalnat, Joanna [1 ]
Gomez, David Garoz [1 ,2 ]
Daelemans, Lode [1 ]
De Baere, Ives [1 ]
De Clerck, Karen [1 ]
Van Paepegem, Wim [1 ]
机构
[1] Univ Ghent, Dept Mat Text & Chem Engn MaTCh, Technol Pk Zwijnaarde 46-70, B-9052 Zwijnaarde, Belgium
[2] IMDEA Mat, C Erik Kandel 2,Parque Cient & Tecnol Tecnogetafe, Madrid 28906, Spain
关键词
DMA; Accuracy; Repeatability; 3-Point-bending; PESU; Technoform-PP; GUIDELINES;
D O I
10.1016/j.polymertesting.2020.106799
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Long-term predictions of material properties such as stiffness and creep resistance are important in many engineering applications and require high reliability and accuracy. This is especially true for polymer materials and their composites as their viscoelastic nature results in time-dependent material behaviour and any measurement uncertainties or errors amplify in long-term predictions. To measure this behaviour at smallest loadings, Dynamic Mechanical Analysis (DMA) is frequently declared as an ideal method. However, the measurement accuracy and repeatability of this method is strongly influenced by (i) the testing fixture and corresponding loading mode, (ii) the sample preparation and (iii) the plotting scale to interpret the test results. In this study, relevant experimental parameters were found for DMA and a proper procedure was designed, which was then applied to measure the viscoelastic behaviour of a highly temperature and creep resistant thermoplastic polymer (polyethersulfone) and of a highly graphite filled polypropylene composite. In combination with finite element simulations and in-situ strain measurements by digital image correlation (DIC), the main influences on measurement accuracy of three-point-bending DMA were identified and subsequently used to determine measurement guidelines. Using these guidelines, DMA measurements allow quantitative determination of the viscoelastic response for rigid polymer and composite materials.
引用
收藏
页数:10
相关论文
共 30 条
[21]   Guidelines for performing storage modulus measurements using the TA Instruments DMA 2980 three-point bend mode II. Contact stresses and machine compliance [J].
Shao, Q ;
Lee-Sullivan, P .
POLYMER TESTING, 2000, 19 (03) :239-250
[22]  
Solvay, 2014, VER 301 POL
[23]   Anomalies, Influencing Factors, and Guidelines for DMA Testing of Fiber Reinforced Composites [J].
Swaminathan, Gowthaman ;
Shivakumar, Kunigal N. ;
Russell, Larry C., Jr. .
POLYMER COMPOSITES, 2009, 30 (07) :962-969
[24]  
TA Instruments, 2002, 2980 DMA STRESS STRA
[25]  
TA Instruments, 2016, DYNAMIC MECH ANAL
[26]  
TA Instruments, 2010, THERM AN Q800 SPEC
[27]  
TA Instruments, DMA ONL HELP
[28]   Time-temperature superposition principle applied to a kenaf-fiber/high-density polyethylene composite [J].
Tajvidi, M ;
Falk, RH ;
Hermanson, JC .
JOURNAL OF APPLIED POLYMER SCIENCE, 2005, 97 (05) :1995-2004
[29]  
Toledo A.G. Mettler, 2014, DYN MECH AN SETS NEW
[30]   Anisotropic nanoparticles as templates for the crystalline structure of an injection-molded isotactic polypropylene/TiO2 nanocomposite [J].
Zhang, Peng ;
Kraus, Tobias .
POLYMER, 2017, 130 :161-169