Influencing parameters on measurement accuracy in dynamic mechanical analysis of thermoplastic polymers and their composites

被引:17
作者
Schalnat, Joanna [1 ]
Gomez, David Garoz [1 ,2 ]
Daelemans, Lode [1 ]
De Baere, Ives [1 ]
De Clerck, Karen [1 ]
Van Paepegem, Wim [1 ]
机构
[1] Univ Ghent, Dept Mat Text & Chem Engn MaTCh, Technol Pk Zwijnaarde 46-70, B-9052 Zwijnaarde, Belgium
[2] IMDEA Mat, C Erik Kandel 2,Parque Cient & Tecnol Tecnogetafe, Madrid 28906, Spain
关键词
DMA; Accuracy; Repeatability; 3-Point-bending; PESU; Technoform-PP; GUIDELINES;
D O I
10.1016/j.polymertesting.2020.106799
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Long-term predictions of material properties such as stiffness and creep resistance are important in many engineering applications and require high reliability and accuracy. This is especially true for polymer materials and their composites as their viscoelastic nature results in time-dependent material behaviour and any measurement uncertainties or errors amplify in long-term predictions. To measure this behaviour at smallest loadings, Dynamic Mechanical Analysis (DMA) is frequently declared as an ideal method. However, the measurement accuracy and repeatability of this method is strongly influenced by (i) the testing fixture and corresponding loading mode, (ii) the sample preparation and (iii) the plotting scale to interpret the test results. In this study, relevant experimental parameters were found for DMA and a proper procedure was designed, which was then applied to measure the viscoelastic behaviour of a highly temperature and creep resistant thermoplastic polymer (polyethersulfone) and of a highly graphite filled polypropylene composite. In combination with finite element simulations and in-situ strain measurements by digital image correlation (DIC), the main influences on measurement accuracy of three-point-bending DMA were identified and subsequently used to determine measurement guidelines. Using these guidelines, DMA measurements allow quantitative determination of the viscoelastic response for rigid polymer and composite materials.
引用
收藏
页数:10
相关论文
共 30 条
[11]  
Dealy J., 2009, RHEOL B, V78, P16
[12]  
Grein C., 2004, POTENTIAL LIMITS DYN
[13]   CHARACTERIZATION OF A FIBER-REINFORCED PPS COMPOSITE BY DYNAMIC-MECHANICAL ANALYSIS - EFFECT OF ASPECT RATIO AND STATIC STRESS [J].
LEE, TH ;
BOEY, FYC ;
LOH, NL .
COMPOSITES SCIENCE AND TECHNOLOGY, 1993, 49 (03) :217-223
[14]   Guidelines for performing storage modulus measurements using the TA Instruments DMA 2980 three-point bend mode I. Amplitude effects [J].
Lee-Sullivan, P ;
Dykeman, D .
POLYMER TESTING, 2000, 19 (02) :155-164
[15]   Bending characterisation of a molten unidirectional carbon fibre reinforced thermoplastic composite using a Dynamic Mechanical Analysis system [J].
Margossian, A. ;
Bel, S. ;
Hinterhoelzl, R. .
COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2015, 77 :154-163
[16]   DMA Testing of Epoxy Resins: The Importance of Dimensions [J].
McAninch, Ian M. ;
Palmese, Giuseppe R. ;
Lenhart, Joseph L. ;
La Scala, John J. .
POLYMER ENGINEERING AND SCIENCE, 2015, 55 (12) :2761-2774
[17]  
Mettler M, 2016, 2016 IEEE 18TH INTERNATIONAL CONFERENCE ON E-HEALTH NETWORKING, APPLICATIONS AND SERVICES (HEALTHCOM), P520
[18]  
PerkinElmer, 2008, BEG GUID DYN MECH AN
[19]  
PerkinElmer, 2013, 800 DMA
[20]  
PPSU, 2014, RAD PPSU VER PESU AC