Post-earthquake fire performance of square concrete-filled steel tube columns

被引:20
|
作者
Wang, Yu-Hang [1 ,2 ]
Tang, Qi [3 ]
Su, Mei-Ni [4 ]
Tan, Ji-Ke [2 ]
Wang, Wei-Yong [2 ]
Lan, Yong-Sen [5 ]
Luo, Wei [5 ]
Zhou, Yang [5 ]
机构
[1] China Earthquake Adm, Inst Engn Mech, Key Lab Earthquake Engn & Engn Vibrat, Beijing, Peoples R China
[2] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
[3] CISDI Engn CO LTD, Chongqing 400013, Peoples R China
[4] Univ Manchester, Dept Mech Aerosp & Civil Engn, Manchester M1 3NJ, Lancs, England
[5] CSIC HaiZhuang Wind Power Co Ltd, Chongqing 401122, Peoples R China
关键词
Design method; Finite element; Fire resistance; Seismic damage; Square concrete-filled steel tube; STRUCTURAL PERFORMANCE; BEHAVIOR; RESISTANCE; DESIGN; BEAMS; MODEL;
D O I
10.1016/j.tws.2020.106873
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
It has been shown that fire disaster normally occurs following an earthquake disaster, which might cause even more serious losses than the earthquake itself. This study investigates the post-earthquake fire performance of concrete-filled steel tube (CFST) columns. The experimental programme contains two parts - quasi-static tests and fire tests. During the quasi-static tests, the square CFST columns were loaded under constant compressive force and cyclic horizontal force, until reaching different degrees of seismic damage. Afterwards, the pre-damaged columns were loaded under a constant axial compression ratio (i.e. ratio of the applied compressive load to its bearing capacity) of 0.3 at elevated temperatures. The fire resistance time and failure modes of these pre-damaged CFST columns were reported. Finite element (FE) models were developed and validated against the test results; a total of 48 numerical results were generated in the parametric study using the validated model. In the parametric study, the influence of key parameters including the thickness of steel tube, the yield strength of steel tube, the axial compression ratio and pre-damage degrees on the fire resistance of square CFST columns were analysed. The experimental and numerical results are used to propose design rules for the fire performance of square CFST columns with different degrees of seismic damage.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Experimental and numerical investigation on post-earthquake fire behaviour of the circular concrete-filled steel tube columns
    Wang, Hang
    Tang, Qi
    Su, Mei-Ni
    Tan, Ji-Ke
    Wang, Wei-Yong
    Lan, Yong-Sen
    Deng, Xiao-Wei
    Bai, Yong-Tao
    Luo, Wei
    Li, Xiao-Hua
    Bai, Jiu-Lin
    STEEL AND COMPOSITE STRUCTURES, 2021, 38 (01): : 17 - 31
  • [2] Post-Earthquake Fire Resistance of Circular Concrete-Filled Steel Tubular Columns
    Wang, J. H.
    Kunnath, S.
    He, J.
    Xiao, Y.
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (06)
  • [3] Experimental and numerical investigation of circular concrete-filled steel tubular columns subjected to post-earthquake fires
    Wei, Guo-Qiang
    Wang, Wen-Da
    Zhou, Kan
    Mao, Wen-Jing
    ENGINEERING STRUCTURES, 2025, 332
  • [4] Post-earthquake fire performance of partially encased composite steel and concrete columns
    Zhang, Lingyue
    Wang, Wei
    Lou, Ting
    Hou, Haowen
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 222
  • [5] Performance of recycled aggregate concrete-filled square steel tubular columns exposed to fire
    Yang, You-Fu
    Zhang, Lei
    Dai, Xianghe
    ADVANCES IN STRUCTURAL ENGINEERING, 2017, 20 (09) : 1340 - 1356
  • [6] The performance of concrete filled steel tube columns under post earthquake fires
    Talebi, Elnaz
    Korzen, Manfred
    Hothan, Sascha
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2018, 150 : 115 - 128
  • [7] Experimental Study on Post-Earthquake Fire Resistance of Ductile Concrete-Filled Double-Skin Tube Columns
    Imani, R.
    Mosqueda, G.
    Bruneau, M.
    JOURNAL OF STRUCTURAL ENGINEERING, 2015, 141 (08)
  • [8] Performance Investigation of Square Concrete-filled Steel Tube Columns
    Chen Bing
    Liu Xiao
    Li Siping
    JOURNAL OF WUHAN UNIVERSITY OF TECHNOLOGY-MATERIALS SCIENCE EDITION, 2011, 26 (04): : 730 - 736
  • [9] POST-FIRE PERFORMANCE OF ELLIPTICAL CONCRETE-FILLED STEEL TUBE STUB COLUMNS
    Song, T. Y.
    Zhang, J. C.
    Xiang, K.
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON STEEL AND ALUMINIUM STRUCTURES (ICSAS19), 2019, : 1459 - 1469
  • [10] Post-earthquake fire performance of reinforced concrete columns
    Wen, Bo
    Wu, Bo
    Niu, Ditao
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2016, 12 (09) : 1106 - 1126