In vivo pH monitoring using boron doped diamond microelectrode and silver needles: Application to stomach disorder diagnosis

被引:35
作者
Fierro, Stephane [1 ]
Seishima, Ryo [2 ]
Nagano, Osamu [2 ]
Saya, Hideyuki [2 ,3 ]
Einaga, Yasuaki [1 ,3 ]
机构
[1] Keio Univ, Dept Chem, Fac Sci & Technol, Yokohama, Kanagawa 2238522, Japan
[2] Keio Univ, Inst Adv Med Res, Div Gene Regulat, Tokyo 1608582, Japan
[3] CREST, JST, Chiyoda Ku, Tokyo 1020075, Japan
关键词
PROTON PUMP INHIBITOR;
D O I
10.1038/srep03257
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study presents the in vivo electrochemical monitoring of pH using boron doped diamond (BDD) microelectrode and silver needles for potential application in medical diagnosis. Accurate calibration curve for pH determination were obtained through in vitro electrochemical measurements. The increase induced in stomach pH by treatment with pantoprazole was used to demonstrate that it is possible to monitor the pH in vivo using the simple and noninvasive system proposed herein. Using the results of the in vivo and in vitro experiments, a quantitative analysis of the increase in stomach pH is also presented. It is proposed that the catheter-free pH monitoring system presented in this study could be potentially employed in any biological environment.
引用
收藏
页数:4
相关论文
共 19 条
[1]  
Bates R.G., 1973, DETERMINATION PH THE, V2nd
[2]   The role of disturbed pH dynamics and the Na+/H+ exchanger in metastasis [J].
Cardone, RA ;
Casavola, V ;
Reshkin, SJ .
NATURE REVIEWS CANCER, 2005, 5 (10) :786-795
[3]   pH-dependent antitumor activity of proton pump inhibitors against human melanoma is mediated by inhibition of tumor acidity [J].
De Milito, Angelo ;
Canese, Rossella ;
Marino, Maria Lucia ;
Borghi, Martina ;
Iero, Manuela ;
Villa, Antonello ;
Venturi, Giulietta ;
Lozupone, Francesco ;
Iessi, Elisabetta ;
Logozzi, Mariantonia ;
Della Mina, Pamela ;
Santinami, Mario ;
Rodolfo, Monica ;
Podo, Franca ;
Rivoltini, Licia ;
Fais, Stefano .
INTERNATIONAL JOURNAL OF CANCER, 2010, 127 (01) :207-219
[4]  
Dole M., 1941, GLASS ELECTRODE
[5]  
Eisenman G., 1967, GLASSELECTRODES HYDR
[6]   pH sensing using boron doped diamond electrodes [J].
Fierro, Stephane ;
Mitani, Naoko ;
Comninellis, Christos ;
Einaga, Yasuaki .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2011, 13 (37) :16795-16799
[7]  
Fujishima, 2005, DIAMOND ELECTROCHEMI
[8]   Tumor pH: Implications for treatment and novel drug design [J].
Gerweck, LE .
SEMINARS IN RADIATION ONCOLOGY, 1998, 8 (03) :176-182
[9]   ACG practice guidelines: Esophageal reflux testing [J].
Hirano, Ikuo ;
Richter, Joel E. .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2007, 102 (03) :668-685
[10]  
KROMER W, 1990, J PHARMACOL EXP THER, V254, P129