Histology of saphenous veins after treatment with the ClariVein® device - an ex-vivo experiment

被引:18
|
作者
Kendler, Michael [1 ]
Averbeck, Marco [1 ]
Simon, Jan C. [1 ]
Ziemer, Mirjana [1 ]
机构
[1] Univ Klinikum Leipzig AoR, Klin & Poliklin Dermatol Venerol & Allergol, D-04103 Leipzig, Germany
关键词
VARICOSE-VEINS; LASER-ABLATION; RADIOFREQUENCY; DAMAGE;
D O I
10.1111/ddg.12022
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background: Endovenous treatment modalities are used increasingly to treat varicose veins. The ClariVein((R)) catheter is a new endoluminal mechanico-chemical obliteration technique which can be used without tumescent anesthesia. It is still unclear what changes the mechanical tip of the catheter has on the walls of the vein. Patients and methods: Five great saphenous vein specimens were obtained atraumatically by crossectomy. Then the veins were treated ex vivo with the ClariVein((R)) catheter without sclerotherapy. The activated catheter rotating tip (3 500 U/min) was steadily withdrawn at 1-2 mm per second. Subsequently, histological and immunohistochemical investigations of treated (cv) and untreated specimens (plain) were performed. A 4-point score was calculated to compare the results. Results: The mechanical part of the catheter caused a subtle incomplete destruction of the endothelium (endothelium cv: 2.2 vs. plain: 1, p = 0.04). Changes in the media or adventitia were not seen. Immunohistochemical presentation of the endothelium of the intima was demonstrated with antibodies against CD31 (cv: 3.4 vs. plain: 2.8), CD34 (cv: 3.8 vs. plain: 3.2) and factor VIII (cv: 2.2 vs. plain: 1, p = 0,004). Conclusions: The mechanical part of the ClariVein((R)) catheter caused a subtle incomplete destruction of endothelium, which was confirmed histologically and immunohistochemically. The reduced expression of factor VIII in the treated vein could be caused by the release of preformed factor VIII granules due to the minimal mechanical irritation.
引用
收藏
页码:348 / 352
页数:5
相关论文
共 50 条
  • [21] Ex-vivo treatment of gastric Helicobacter infection by photodynamic therapy
    Millson, CE
    Wilson, M
    MacRobert, AJ
    Bown, SG
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 1996, 32 (1-2) : 59 - 65
  • [22] A Novel Device to Preserve Intestinal Tissue Ex-Vivo by Cold Peristaltic Perfusion
    Narayan, Raja R.
    Pancer, Natalie E.
    Loeb, Brian W.
    Oki, Kristi
    Crouch, Andrew
    Backus, Spencer
    Chauhan, Yusuf
    Patron-Lozano, Roger
    Rodriguez-Davalos, Manuel I.
    Geibel, John P.
    Fan, Richard E.
    Zinter, Joseph P.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 3118 - 3121
  • [23] An Ex-Vivo Evaluation of the Application and Strength of a Novel Laparoscopic Knot Substitute Device
    Chi, Thomas
    Eisner, Brian H.
    Berger, Aaron D.
    Stoller, Marshall L.
    JOURNAL OF ENDOUROLOGY, 2010, 24 (01) : 95 - 98
  • [24] A new device to study ex-vivo the effects of extracorporeal photochemotherapy on the immune system
    Rigolio, Roberta
    Perseghin, Paolo
    Jonsson, Svante
    Petersson, Jesper
    Cavaletti, Guido
    Cilio, Corrado Maria
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 2007, 88 (01) : 68 - 75
  • [25] Systematic evaluation of 2μm thulium laser device for treatment of benign prostatic enlargement in an ex-vivo model
    Wendt-Nordahl, Gunnar
    Huckele, Stefanie
    Honeck, Patrick
    Alken, Peter
    Knoll, Thomas
    Michel, Maurice S.
    Haecker, Axel
    JOURNAL OF UROLOGY, 2007, 177 (04): : 614 - 614
  • [26] Ex-vivo evaluation of new 980NM diode laser device for treatment of benign prostatic enlargement
    Wendt-Nordahl, G.
    Huckele, S.
    Honeck, P.
    Alken, P.
    Knoll, T.
    Michel, M. S.
    Hacker, A.
    EUROPEAN UROLOGY SUPPLEMENTS, 2007, 6 (02) : 193 - 193
  • [27] A compact and automated ex vivo vessel culture system for the pulsatile pressure conditioning of human saphenous veins
    Piola, Marco
    Prandi, Francesca
    Bono, Nina
    Soncini, Monica
    Penza, Eleonora
    Agrifoglio, Marco
    Polvani, Gianluca
    Pesce, Maurizio
    Fiore, Gianfranco Beniamino
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2016, 10 (03) : E204 - E215
  • [28] Fluocinolone Acetonide Loaded Chitosan Nanofiber Scaffolds for Treatment of Ocular Disorders: In Vitro Characterization, Ex-Vivo Corneal and Ex-Vivo Scleral Evaluation
    Patel, Zeeshan
    Gharat, Sankalp
    Momin, Munira
    CURRENT EYE RESEARCH, 2024, 49 (05) : 467 - 476
  • [29] Loss of surface enamel after bracket debonding: An in-vivo and ex-vivo evaluation
    Pont, Huib Berghauser
    Oezcan, Mutlu
    Bagis, Bora
    Ren, Yijin
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 138 (04) : 387 - 389
  • [30] Proof of Concept Design of an Ex-Vivo Lung Perfusion (EVLP) Device to Evaluate Optimal Ex Vivo Hemodynamic Environments for Donation After Cardiac Death (DCD) Lungs
    Luo, N.
    Kiang, S.
    Mattar, A.
    Loor, G.
    Wang, Y.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (04): : S311 - S312