Saturation pulse design for quantitative myocardial T1 mapping

被引:30
作者
Chow, Kelvin [1 ]
Kellman, Peter [2 ]
Spottiswoode, Bruce S. [3 ]
Nielles-Vallespin, Sonia [2 ]
Arai, Andrew E. [2 ]
Salerno, Michael [4 ,5 ,6 ,7 ]
Thompson, Richard B. [1 ]
机构
[1] Univ Alberta, Fac Med & Dent, Dept Biomed Engn, Res Transit Facil 1082, Edmonton, AB T6G 2V2, Canada
[2] NHLBI, NIH, Dept Hlth & Human Serv, Bethesda, MD 20892 USA
[3] Siemens Med Solut USA Inc, Cardiovasc MR R&D, Chicago, IL USA
[4] Univ Virginia Hlth Syst, Dept Med, Div Cardiovasc, Charlottesville, VA USA
[5] Univ Virginia Hlth Syst, Dept Radiol, Charlottesville, VA USA
[6] Univ Virginia Hlth Syst, Dept Med Imaging, Charlottesville, VA USA
[7] Univ Virginia Hlth Syst, Biomed Engn, Charlottesville, VA USA
基金
美国国家卫生研究院; 加拿大健康研究院;
关键词
Saturation pulses; Adiabatic pulses; B-0; inhomogeneity; B-1; T-1; mapping; Saturation recovery; SASHA; HEART; PERFUSION; TRAIN; COIL;
D O I
10.1186/s12968-015-0187-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Quantitative saturation-recovery based T-1 mapping sequences are less sensitive to systematic errors than the Modified Look-Locker Inversion recovery (MOLLI) technique but require high performance saturation pulses. We propose to optimize adiabatic and pulse train saturation pulses for quantitative T1 mapping to have <1 % absolute residual longitudinal magnetization (vertical bar M-Z/M-0 vertical bar) over ranges of B-0 and <(B)over cap>(1) (B-1 scale factor) inhomogeneity found at 1.5 T and 3 T. Methods: Design parameters for an adiabatic BIR4-90 pulse were optimized for improved performance within 1.5 T B-0 (+/- 120 Hz) and (B) over cap (1) (0.7-1.0) ranges. Flip angles in hard pulse trains of 3-6 pulses were optimized for 1.5 T and 3 T, with consideration of T-1 values, field inhomogeneities (B-0=+/- 240 H-z and (B) over cap (1)=0.4-1.2 at 3 T), and maximum achievable B-1 field strength. Residual M-Z/M-0 was simulated and measured experimentally for current standard and optimized saturation pulses in phantoms and in-vivo human studies. T-1 maps were acquired at 3 T in human subjects and a swine using a SAturation recovery single-SHot Acquisition (SASHA) technique with a standard 90 degrees-90 degrees-90 degrees and an optimized 6-pulse train. Results: Measured residual M-Z/M-0 in phantoms had excellent agreement with simulations over a wide range of B-0 and (B) over cap (1). The optimized BIR4-90 reduced the maximum residual vertical bar M-Z/M-0 vertical bar to <1 %, a 5.8x reduction compared to a reference BIR4-90. An optimized 3-pulse train achieved a maximum residual vertical bar M-Z/M-0 vertical bar <1 % for the 1.5 T optimization range compared to 11.3 % for a standard 90 degrees-90 degrees-90 degrees pulse train, while a 6-pulse train met this target for the wider 3 T ranges of B0 and (B) over cap (1). The 6-pulse train demonstrated more uniform saturation across both the myocardium and entire field of view than other saturation pulses in human studies. T1 maps were more spatially homogeneous with 6-pulse train SASHA than the reference 90 degrees-90 degrees-90 degrees SASHA in both human and animal studies. Conclusions: Adiabatic and pulse train saturation pulses optimized for different constraints found at 1.5 T and 3 T achieved <1 % residual vertical bar M-Z/M-0 vertical bar in phantom experiments, enabling greater accuracy in quantitative saturation recovery T-1 imaging.
引用
收藏
页数:15
相关论文
共 22 条
  • [1] Chow K, 2014, J CARDIOVASC MAGN S1, V16, pM9, DOI DOI 10.1186/1532-429X-16-S1-M9
  • [2] Saturation Recovery Single-Shot Acquisition (SASHA) for Myocardial T1 Mapping
    Chow, Kelvin
    Flewitt, Jacqueline A.
    Green, Jordin D.
    Pagano, Joseph J.
    Friedrich, Matthias G.
    Thompson, Richard B.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (06) : 2082 - 2095
  • [3] Saturated double-angle method for rapid B1 plus mapping
    Cunningham, Charles H.
    Pauly, John M.
    Nayak, Krishna S.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (06) : 1326 - 1333
  • [4] SYMMETRICAL PULSES TO INDUCE ARBITRARY FLIP ANGLES WITH COMPENSATION FOR RF INHOMOGENEITY AND RESONANCE OFFSETS
    GARWOOD, M
    KE, Y
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1991, 94 (03) : 511 - 525
  • [5] T1 measurement using a short acquisition period for quantitative cardiac applications
    Higgins, DM
    Ridgway, JP
    Radjenovic, A
    Sivananthan, UM
    Smith, MA
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1738 - 1746
  • [6] Optimized saturation recovery protocols for T1-mapping in the heart: influence of sampling strategies on precision
    Kellman, Peter
    Xue, Hui
    Chow, Kelvin
    Spottiswoode, Bruce S.
    Arai, Andrew E.
    Thompson, Richard B.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
  • [7] T1-mapping in the heart: accuracy and precision
    Kellman, Peter
    Hansen, Michael S.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
  • [8] Adiabatic Inversion Pulses for Myocardial T1 Mapping
    Kellman, Peter
    Herzka, Daniel A.
    Hansen, Michael Schacht
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (04) : 1428 - 1434
  • [9] Hybrid Adiabatic-Rectangular Pulse Train for Effective Saturation of Magnetization Within the Whole Heart at 3 T
    Kim, Daniel
    Oesingmann, Niels
    McGorty, KellyAnne
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (06) : 1368 - 1378
  • [10] Determining the longitudinal relaxation time (T1) of blood at 3.0 tesla
    Lu, HZ
    Clingman, C
    Golay, X
    van Zijl, PCM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (03) : 679 - 682