Absolute Myocardial Blood Flow and Flow Reserve Assessed by Gated SPECT with Cadmium Zinc Telluride Detectors Using 99mTc-Tetrofosmin: Head-to-Head Comparison with 13N-Ammonia PET

被引:98
作者
Nkoulou, Rene
Fuchs, Tobias A.
Pazhenkottil, Aju P.
Kuest, Silke M.
Ghadri, Jelena R.
Stehli, Julia
Fiechter, Michael
Herzog, Bernhard A.
Gaemperli, Oliver
Buechel, Ronny R.
Kaufmann, Philipp A.
机构
[1] Univ Zurich Hosp, Dept Nucl Med, Cardiac Imaging, Zurich, Switzerland
[2] Univ Zurich, Zurich, Switzerland
关键词
myocardial flow reserve (MFR); myocardial blood flow (MBF); cadmium zinc telluride (CZT) SPECT; N-13-ammonia PET; POSITRON-EMISSION-TOMOGRAPHY; CT ATTENUATION CORRECTION; DYNAMIC SPECT; COMPUTED-TOMOGRAPHY; PROGNOSTIC VALUE; VALIDATION; TL-201; QUANTIFICATION; HETEROGENEITY; REPEATABILITY;
D O I
10.2967/jnumed.115.165498
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recent advances in SPECT technology including cadmium zinc telluride (CZT) semiconductor detector material may pave the way for absolute myocardial blood flow (MBF) measurements by SPECT. The aim of the present study was to compare K-1 uptake rate constants as surrogates of absolute MBF and myocardial flow reserve index (MFRi) in humans as assessed with a CZT SPECT camera versus PET. Methods: Absolute MBF was assessed in 28 consecutive patients undergoing adenosine stress rest myocardial perfusion imaging (MPI) by Tc-99m-tetrofosmin CZT SPECT and N-13-ammonia PET, and MFR was calculated as a ratio of hyperemic over resting MBF. Results from both MPI methods were compared, and correlation coefficients were calculated. The diagnostic accuracy of CZT MFRi to predict an abnormal MFR defined as PET MFR less than 2 was assessed using a receiver-operator-characteristic curve. Results: Median MBF at rest was comparable between CZT and PET (0.89 [interquartile range (IQR), 0.77-1.00] vs. 0.92 [IQR, 0.78-1.06] mL/g/min; P = not significant) whereas it was significantly lower at stress in CZT than PET (1.11 [IQR, 1.00-1.26] vs. 2.06 [IQR, 1.48-2.56] mUg/min; P < 0.001). This resulted in median MFRi values of 1.32 (IQR, 1.13-1.52) by CZT and 2.36 (IQR, 1.57-2.71) by PET (P < 0.001). The receiver-operator-characteristic curve revealed a cutoff for CZT MFRi at 1.26 to predict an abnormal PET MFR yielding an accuracy of 75%. Conclusion: The estimation of absolute MBF index values by CZT SPECT MPI with 99mTc-tetrofosmin is technically feasible, although hyperemic values are significantly lower than from PET with N-13-ammonia, resulting in a substantial underestimation of MFR. Nevertheless, CZT MFRi may confer diagnostic value.
引用
收藏
页码:1887 / 1892
页数:6
相关论文
共 35 条
[1]  
Alhassen F, 2014, AM J NUCL MED MOLEC, V4, P53
[2]   PROFOUND SPATIAL HETEROGENEITY OF CORONARY RESERVE - DISCORDANCE BETWEEN PATTERNS OF RESTING AND MAXIMAL MYOCARDIAL BLOOD-FLOW [J].
AUSTIN, RE ;
ALDEA, GS ;
COGGINS, DL ;
FLYNN, AE ;
HOFFMAN, JIE .
CIRCULATION RESEARCH, 1990, 67 (02) :319-331
[3]   Quantification of Myocardial Perfusion Reserve Using Dynamic SPECT Imaging in Humans: A Feasibility Study [J].
Ben-Haim, Simona ;
Murthy, Venkatesh L. ;
Breault, Christopher ;
Allie, Rayjanah ;
Sitek, Arkadiusz ;
Roth, Nathaniel ;
Fantony, Jolene ;
Moore, Stephen C. ;
Park, Mi-Ae ;
Kijewski, Marie ;
Haroon, Athar ;
Slomka, Piotr ;
Erlandsson, Kjell ;
Baavour, Rafael ;
Zilberstien, Yoel ;
Bomanji, Jamshed ;
Di Carli, Marcelo F. .
JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (06) :873-879
[4]   A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential [J].
Bocher, Moshe ;
Blevis, Ira M. ;
Tsukerman, Leonid ;
Shrem, Yigal ;
Kovalski, Gil ;
Volokh, Lana .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (10) :1887-1902
[5]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[6]   Heterogeneity of resting and hyperemic myocardial blood flow in healthy humans [J].
Chareonthaitawee, P ;
Kaufmann, PA ;
Rimoldi, O ;
Camici, PG .
CARDIOVASCULAR RESEARCH, 2001, 50 (01) :151-161
[7]   Gated SPECT imaging to detect changes in myocardial blood flow during progressive coronary occlusion [J].
Christian, Timothy F. ;
Peters, Kevin ;
Keck, Bradly ;
Allen, Jill ;
Owens, Thomas ;
Borah, Babul .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2008, 24 (03) :269-276
[8]  
Daniele S, 2011, J NUCL CARDIOL, V18, P612, DOI 10.1007/s12350-011-9345-4
[9]   Estimation of myocardial blood flow for longitudinal studies with N-13-labeled ammonia and positron emission tomography [J].
DeGrado, TR ;
Hanson, MW ;
Turkington, TG ;
Delong, DM ;
Brezinski, DA ;
Vallee, JP ;
Hedlund, LW ;
Zhang, J ;
Cobb, F ;
Sullivan, MJ ;
Coleman, RE .
JOURNAL OF NUCLEAR CARDIOLOGY, 1996, 3 (06) :494-507
[10]   Compartmental modeling of technetium-99m-labeled teboroxime with dynamic single-photon emission computed tomography - Comparison with static thallium-201 in a canine model [J].
Di Bella, EVR ;
Ross, SG ;
Kadrmas, DJ ;
Khare, HS ;
Christian, PE ;
McJames, S ;
Gullberg, GT .
INVESTIGATIVE RADIOLOGY, 2001, 36 (03) :178-185