Statistical algorithm for assuring similar efficiency in standards and samples for absolute quantification by real-time reverse transcription polymerase chain reaction

被引:14
作者
Chervoneva, I [1 ]
Hyslop, T
Iglewicz, B
Johns, L
Wolfe, HR
Schulz, S
Leong, E
Waldman, S
机构
[1] Thomas Jefferson Univ, Div Biostat, Philadelphia, PA 19107 USA
[2] Thomas Jefferson Univ, Dept Pharmacol & Expt Therapeut, Philadelphia, PA 19107 USA
[3] Temple Univ, Dept Stat, Philadelphia, PA 19122 USA
[4] Targeted Diagnost & Therapeut Inc, W Chester, PA 19380 USA
关键词
RT-PCR efficiency; amplification rate; accuracy of absolute quantification; kinetic outliers;
D O I
10.1016/j.ab.2005.10.042
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Reverse transcription (RT) followed by the polymerase chain reaction (PCR) is the method of choice for quantifying rare transcripts in biological samples. A key assumption underlying the absolute quantification of transcripts is similar amplification efficiencies of all external standards and samples. However, efficiencies can vary between individual reactions, a problem that can be magnified when quantifying transcripts of low abundance. Here, an algorithm to assure that calibration standards and samples meet the assumption of similar amplification efficiencies underlying absolute quantification is presented. Individual reaction efficiency is estimated by fitting an exponential growth model to the fluorescence data in the exponential phase of the reaction. Next, reactions of standards with outlying estimates of amplification rates are eliminated using the boxplot outlier detection rule. Then, estimates of amplification rates of outlier-free standards are employed to define exact tolerance intervals, which are used to eliminate kinetic outliers from test samples. This algorithm was employed to eliminate kinetic outliers prior to defining the baseline expression of guanylyl cyclase C mRNA, a marker for colorectal cancer, in blood of healthy volunteers. These studies demonstrate that elimination of kinetic outliers from calibration standards and test samples improves the accuracy of absolute transcript quantification by RT-PCR. (C) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:198 / 208
页数:11
相关论文
共 34 条
[1]   A quantitative, internally controlled real-time PCR Assay for the detection of parvovirus B19 DNA [J].
Aberham, C ;
Pendl, C ;
Gross, P ;
Zerlauth, G ;
Gessner, P .
JOURNAL OF VIROLOGICAL METHODS, 2001, 92 (02) :183-191
[2]  
[Anonymous], 1986, ROBUST STAT
[3]   Kinetic Outlier Detection (KOD) in real-time PCR -: art. no. e105 [J].
Bar, T ;
Ståhlberg, A ;
Muszta, A ;
Kubista, M .
NUCLEIC ACIDS RESEARCH, 2003, 31 (17) :e105
[4]   Absolute quantification of mRNA using real-time reverse transcription polymerase chain reaction assays [J].
Bustin, SA .
JOURNAL OF MOLECULAR ENDOCRINOLOGY, 2000, 25 (02) :169-193
[5]   Guanylyl cyclase C messenger RNA is a biomarker for recurrent stage II colorectal cancer [J].
Cagir, B ;
Gelmann, A ;
Park, J ;
Fava, T ;
Tankelevitch, A ;
Bittner, EW ;
Weaver, EJ ;
Palazzo, JP ;
Weinberg, D ;
Fry, RD ;
Waldman, SA .
ANNALS OF INTERNAL MEDICINE, 1999, 131 (11) :805-+
[6]  
Chandler DP, 1998, APPL ENVIRON MICROB, V64, P669
[7]   PREPARATION AND CHARACTERIZATION OF RNA STANDARDS FOR USE IN QUANTITATIVE BRANCHED DNA HYBRIDIZATION ASSAYS [J].
COLLINS, ML ;
ZAYATI, C ;
DETMER, JJ ;
DALY, B ;
KOLBERG, JA ;
CHA, TA ;
IRVINE, BD ;
TUCKER, J ;
URDEA, MS .
ANALYTICAL BIOCHEMISTRY, 1995, 226 (01) :120-129
[8]   Ectopic expression of guanylyl cyclase C in CD34+ progenitor cells in peripheral blood [J].
Fava, TA ;
Desnoyers, R ;
Schulz, S ;
Park, J ;
Weinberg, D ;
Mitchell, E ;
Waldman, SA .
JOURNAL OF CLINICAL ONCOLOGY, 2001, 19 (19) :3951-3959
[9]  
Hahn G.J., 1991, Statistical Intervals: A Guide for Practitioners and Researchers, VFirst, DOI 10.1002/
[10]   PERFORMANCE OF SOME RESISTANT RULES FOR OUTLIER LABELING [J].
HOAGLIN, DC ;
IGLEWICZ, B ;
TUKEY, JW .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1986, 81 (396) :991-999