Performance-Aware Energy Saving for Data Center Networks

被引:17
作者
Al-Tarazi, Motassem [1 ]
Chang, J. Morris [2 ]
机构
[1] Iowa State Univ, Dept Comp Sci, Ames, IA 50011 USA
[2] Univ S Florida, Dept Elect Engn, Tampa, FL 33647 USA
来源
IEEE TRANSACTIONS ON NETWORK AND SERVICE MANAGEMENT | 2019年 / 16卷 / 01期
关键词
Data center networks; energy saving; load balancing; POWER OPTIMIZATION; EFFICIENCY; FRAMEWORK;
D O I
10.1109/TNSM.2019.2891826
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Today's data center networks (DCNs) tend to have tens to hundreds of thousands of servers that provide massive and sophisticated services. The architectural design of DCNs are usually over-provisioned for peak workloads and fault tolerance. Statistically, DCNs remain highly under-utilized, with typical utilization of around 30%. Network over-provisioning and under-utilization can be exploited for energy-saving. Most research efforts on DCN energy saving focus on how to save maximum energy but have little or no consideration to the performance of the residual network. Thus, the DCN performance can become degraded and the network left vulnerable to sudden traffic surges. In this paper, we have studied the energy-saving problem in DCNs while preserving network performance. The problem was formulated as mixed integer linear problem (MILP) solvable by CPLEX in order to minimize the energy consumed by DCN; meanwhile, safety threshold constraints for links utilization are met. To overcome CPLEX high computational time, a heuristic algorithm to provide practical and efficient solution for the MILP is introduced. The heuristic algorithm uses switches grouping and links consolidation to switch the traffic to a small number of network devices and turn off unused switches and links. Valiant load balancing is used to distribute the loads over active links. Simulation experiments using synthetic and real packet traces were conducted to validate the heuristic in terms of energy consumption and network performance. The results show that the heuristic can save up to 45% of the network energy and improve the average imbalance scores for links and switches by more than 50% with minimal effect on network performance.
引用
收藏
页码:206 / 219
页数:14
相关论文
共 53 条
[1]  
Abts D, 2010, CONF PROC INT SYMP C, P338, DOI 10.1145/1816038.1816004
[2]   Symbiotic Routing in Future Data Centers [J].
Abu-Libdeh, Hussam ;
Costa, Paolo ;
Rowstron, Antony ;
O'Shea, Greg ;
Donnelly, Austin .
ACM SIGCOMM COMPUTER COMMUNICATION REVIEW, 2010, 40 (04) :51-62
[3]   A scalable, commodity data center network architecture [J].
Al-Fares, Mohammad ;
Loukissas, Alexander ;
Vahdat, Amin .
ACM SIGCOMM COMPUTER COMMUNICATION REVIEW, 2008, 38 (04) :63-74
[4]  
Al-Fares Mohammad, 2010, Hedera: dynamic flow scheduling for data center networks (NSDI'10)
[5]  
[Anonymous], 2012, VMware Technical J
[6]  
[Anonymous], 2011, Growth in Data Center Electricity Use 2005 to 2010
[7]  
[Anonymous], 2007, CISC DAT CTR INFR 2
[8]  
[Anonymous], 2018, CISCO NEXUS 7000 SER
[9]  
Benson T., 2010, Proceedings of the 10th annual conference on Internet measurement - IMC '10, P267, DOI [DOI 10.1145/1879141.1879175, 10.1145/1879141.1879175]
[10]   A taxonomy and survey on Green Data Center Networks [J].
Bilal, Kashif ;
Malik, Saif Ur Rehman ;
Khalid, Osman ;
Hameed, Abdul ;
Alvarez, Enrique ;
Wijaysekara, Vidura ;
Irfan, Rizwana ;
Shrestha, Sarjan ;
Dwivedy, Debjyoti ;
Ali, Mazhar ;
Khan, Usman Shahid ;
Abbas, Assad ;
Jalil, Nauman ;
Khan, Samee U. .
FUTURE GENERATION COMPUTER SYSTEMS-THE INTERNATIONAL JOURNAL OF ESCIENCE, 2014, 36 :189-208