Optical coherence tomography for blood glucose monitoring in vitro through spatial and temporal approaches

被引:30
作者
De Pretto, Lucas Ramos [1 ,2 ]
Yoshimura, Tania Mateus [1 ,2 ]
Ribeiro, Martha Simoes [1 ]
de Freitas, Anderson Zanardi [1 ]
机构
[1] Nucl & Energy Res Inst, Ave Prof Lineu Prestes 2242, BR-05508000 Sao Paulo, SP, Brazil
[2] Univ Sao Paulo, Postgrad Program Nucl Technol, Ave Prof Lineu Prestes 2242, BR-05508000 Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
noninvasive; diabetes; attenuation coefficient; speckle decorrelation; glycemic control; mouse blood; SEDIMENTATION; SPECKLE; INSULIN; TISSUE;
D O I
10.1117/1.JBO.21.8.086007
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
As diabetes causes millions of deaths worldwide every year, new methods for blood glucose monitoring are in demand. Noninvasive approaches may increase patient adherence to treatment while reducing costs, and optical coherence tomography (OCT) may be a feasible alternative to current invasive diagnostics. This study presents two methods for blood sugar monitoring with OCT in vitro. The first, based on spatial statistics, exploits changes in the light total attenuation coefficient caused by different concentrations of glucose in the sample using a 930-nm commercial OCT system. The second, based on temporal analysis, calculates differences in the decorrelation time of the speckle pattern in the OCT signal due to blood viscosity variations with the addition of glucose with data acquired by a custom built Swept Source 1325-nm OCT system. Samples consisted of heparinized mouse blood, phosphate buffer saline, and glucose. Additionally, further samples were prepared by diluting mouse blood with isotonic saline solution to verify the effect of higher multiple scattering components on the ability of the methods to differentiate glucose levels. Our results suggest a direct relationship between glucose concentration and both decorrelation rate and attenuation coefficient, with our systems being able to detect changes of 65 mg/dL in glucose concentration. (C) 2016 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:7
相关论文
共 43 条
[1]  
Abegunde D., 2006, ESTIMATION EC IMPACT, P21
[2]   Validation of quantitative attenuation and backscattering coefficient measurements by optical coherence tomography in the concentration-dependent and multiple scattering regime [J].
Almasian, Mitra ;
Bosschaart, Nienke ;
van Leeuwen, Ton G. ;
Faber, Dirk J. .
JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (12)
[3]  
Alwan A, 2011, GLOBAL STATUS REPORT ON NONCOMMUNICABLE DISEASES 2010, P1
[4]   Standards of Medical Care in Diabetes-2015: Summary of Revisions [J].
不详 .
DIABETES CARE, 2015, 38 :S4-S4
[5]  
[Anonymous], 2005, Preventing chronic diseases: A vital investment
[6]   A glucose sensing contact lens: A non-invasive technique for continuous physiological glucose monitoring [J].
Badugu, R ;
Lakowicz, JR ;
Geddes, CD .
JOURNAL OF FLUORESCENCE, 2003, 13 (05) :371-374
[7]   Glucose monitoring in vivo by measuring laser-induced acoustic profiles [J].
Bednov, A ;
Karabutov, A ;
Savateeva, E ;
March, W ;
Oraevsky, A .
BIOMEDICAL OPTOACOUSTICS, 2000, 3916 :9-18
[8]  
Brezinski M, 2001, CIRCULATION, V103, P1999
[9]   Diabetes, aging, and their tissue complications [J].
Bucala, Rick .
JOURNAL OF CLINICAL INVESTIGATION, 2014, 124 (05) :1887-1888
[10]   First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system [J].
Caduff, A ;
Hirt, E ;
Feldman, Y ;
Ali, Z ;
Heinemann, L .