Environmental Durability of FRP Bar-to-Concrete Bond: Critical Review

被引:37
作者
Gravina, Rebecca J. [1 ]
Li, Junwei [1 ]
Smith, Scott T. [2 ]
Visintin, Phillip [2 ]
机构
[1] RMIT Univ, Sch Engn, 124 La Trobe St, Melbourne, Vic 3000, Australia
[2] Univ Adelaide, Sch Civil Environm & Min Engn, Adelaide, SA 5005, Australia
基金
澳大利亚研究理事会;
关键词
Environmental durability; Fiber-reinforced polymer bar; Reinforced concrete; Bond; Pull-out test; FIBER-REINFORCED-POLYMER; LONG-TERM DURABILITY; BASALT-FIBER; GFRP BARS; BFRP BARS; MECHANICAL-PROPERTIES; SEAWATER CONDITIONS; HIGH-TEMPERATURE; PLASTIC BARS; RC BEAMS;
D O I
10.1061/(ASCE)CC.1943-5614.0001016
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Although fiber-reinforced polymer (FRP) materials are considered noncorrosive, the FRP bar surface resin has been shown to deteriorate when exposed to aggressive environments and this can result in a significant loss of bond strength with the surrounding concrete. To study the durability of the FRP bar-to-concrete bond, numerous investigations utilizing the FRP bar pull-out test arrangement have been conducted. These studies have, however, largely been considered in isolation without any systematic attempt to critically analyze the ever increasing pool of results based on variable exposure regimes and differing geometric and mechanical properties. To address this limitation, and to quantify the durability of the FRP bar-to-concrete bond, this paper presents an experimental database comprising 1,244 individual test results from 35 unique studies which were critically analyzed in terms of bond performance. The analysis highlighted the large scatter that exists for experimental results between studies and attempted to explain this scatter through discussion of the impact of exposure to material properties and the importance of sound experimental design.
引用
收藏
页数:18
相关论文
共 113 条
[1]   Temperature and environmental effects on glass fibre rebar: modulus, strength and interfacial bond strength with concrete [J].
Abbasi, A ;
Hogg, PJ .
COMPOSITES PART B-ENGINEERING, 2005, 36 (05) :394-404
[2]  
Abedi S, 2014, THESIS
[3]   DEGRADATION OF CROSSLINKED RESINS IN WATER AND ELECTROLYTE-SOLUTIONS [J].
ABEYSINGHE, HP ;
EDWARDS, W ;
PRITCHARD, G ;
SWAMPILLAI, GJ .
POLYMER, 1982, 23 (12) :1785-1790
[4]   Bond behavior of fiber reinforced polymer bars under direct pullout conditions [J].
Achillides, Z ;
Pilakoutas, K .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2004, 8 (02) :173-181
[5]  
ACI (American Concrete Institute), 2015, 4409R15 ACI
[6]  
Al-Dulaijan SU, 2001, J REINF PLAST COMP, V20, P881, DOI 10.1177/073168401772678986
[7]  
Al-Sahawneh E.I., 2013, Contemporary Engineering Sciences, V6, P57, DOI [10.12988/ces.2013.13006, DOI 10.12988/CES.2013.13006]
[8]   Effects of harsh environmental exposures on the bond capacity between concrete and GFRP reinforcing bars [J].
Al-Tamimi, Adil ;
Abed, Farid H. ;
Al-Rahmani, Abdulla .
ADVANCES IN CONCRETE CONSTRUCTION, 2014, 2 (01) :1-11
[9]  
Al-Zahrani M. M, 2002, P 6 SAUD ENG C, V2, P379
[10]   Evaluation of bond using FRP rods with axisymmetric deformations [J].
Al-Zahrani, MM ;
Al-Dulaijan, SU ;
Nanni, A ;
Bakis, CE ;
Boothby, TE .
CONSTRUCTION AND BUILDING MATERIALS, 1999, 13 (06) :299-309