Hepatic lesion detection at MR imaging: A comparative study with four sequences

被引:61
作者
Blakeborough, A [1 ]
Ward, J [1 ]
Wilson, D [1 ]
Griffiths, M [1 ]
Kajiya, Y [1 ]
Guthrie, JA [1 ]
Robinson, PJA [1 ]
机构
[1] ST JAMES UNIV HOSP,DEPT RADIOL,MAGNET RESONANCE IMAGING UNIT,LEEDS LS9 7TF,W YORKSHIRE,ENGLAND
关键词
gadolinium; ion; liver neoplasms; MR; magnetic resonance (MR); contrast enhancement; pulse sequences; receiver operating characteristic curve (ROC);
D O I
10.1148/radiology.203.3.9169701
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare results with the following magnetic resonance (MR) imaging sequences in the detection of focal hepatic lesions: fast spin-echo (SE) before and after administration of superparamagnetic iron oxide (SPIO) particles, fat-suppressed T2-weighted SE, and dynamic gadolinium-enhanced fast low-angle shot (FLASH). MATERIALS AND METHODS: In 26 patients with known malignancy and documented focal liver lesions, 1.0-T MR imaging was performed prior to hepatic resection. All images were reviewed independently by four blinded observers. Sensitivity was calculated for each sequence and for each observer by means of alternative-free-response receiver operating characteristic (ROC) methods. RESULTS: The mean area under the alternative-free-response ROC curve with SPIO-enhanced fast SE (0.85) was significantly greater (P < .02) than that with all other Sequences. Detection was significantly improved with SPIO-enhanced fast SE compared with dynamic gadolinium-enhanced FLASH (which was the best of the other three sequences) for all lesions (P < .002) and for malignant lesions (P < .0002). CONCLUSION Findings with the SPIO-enhanced fast SE sequence improved detection of focal liver lesions and had the highest diagnostic accuracy.
引用
收藏
页码:759 / 765
页数:7
相关论文
共 31 条
[1]   HEPATIC METASTASES - BASIC PRINCIPLES AND IMPLICATIONS FOR RADIOLOGISTS [J].
BAKER, ME ;
PELLEY, R .
RADIOLOGY, 1995, 197 (02) :329-337
[2]   LIVER METASTASES - SAFETY AND EFFICACY OF DETECTION WITH SUPERPARAMAGNETIC IRON-OXIDE IN MR-IMAGING [J].
BELLIN, MF ;
ZAIM, S ;
AUBERTON, E ;
SARFATI, G ;
DURON, JJ ;
KHAYAT, D ;
GRELLET, J .
RADIOLOGY, 1994, 193 (03) :657-663
[4]   FREE-RESPONSE METHODOLOGY - ALTERNATE ANALYSIS AND A NEW OBSERVER-PERFORMANCE EXPERIMENT [J].
CHAKRABORTY, DP ;
WINTER, LHL .
RADIOLOGY, 1990, 174 (03) :873-881
[5]   SUPERPARAMAGNETIC IRON-OXIDE - DETECTION OF FOCAL LIVER-LESIONS AT HIGH-FIELD-STRENGTH MR-IMAGING [J].
DUDA, SH ;
LANIADO, M ;
KOPP, AF ;
GRONEWALLER, E ;
AICHER, KP ;
PAVONE, P ;
JEHLE, E ;
CLAUSSEN, CD .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03) :309-314
[6]   IRON-OXIDE ENHANCED MR-IMAGING OF THE LIVER AND SPLEEN - REVIEW OF THE 1ST-5 YEARS [J].
FERRUCCI, JT ;
STARK, DD .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (05) :943-950
[7]   SUPERPARAMAGNETIC IRON OXIDE-ENHANCED MR IMAGING - PULSE SEQUENCE OPTIMIZATION FOR DETECTION OF LIVER-CANCER [J].
FRETZ, CJ ;
ELIZONDO, G ;
WEISSLEDER, R ;
HAHN, PF ;
STARK, DD ;
FERRUCCI, JT .
RADIOLOGY, 1989, 172 (02) :393-397
[8]   DETECTION OF HEPATIC METASTASES - COMPARISON OF CONTRAST-ENHANCED CT, UNENHANCED MR IMAGING, AND IRON-OXIDE ENHANCED MR IMAGING [J].
FRETZ, CJ ;
STARK, DD ;
METZ, CE ;
ELIZONDO, G ;
WEISSLEDER, R ;
SHEN, JH ;
WITTENBERG, J ;
SIMEONE, J ;
FERRUCCI, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (04) :763-770
[9]   DETECTION OF LIVER METASTASES - COMPARISON OF SUPERPARAMAGNETIC IRON OXIDE-ENHANCED AND UNENHANCED MR-IMAGING ART 1.5 T WITH DYNAMIC CT, INTRAOPERATIVE US, AND PERCUTANEOUS US [J].
HAGSPIEL, KD ;
NEIDL, KFW ;
EICHENBERGER, AC ;
WEDER, W ;
MARINCEK, B .
RADIOLOGY, 1995, 196 (02) :471-478
[10]   CONTRAST-ENHANCED MR-IMAGING OF LIVER AND SPLEEN - 1ST EXPERIENCE IN HUMANS WITH A NEW SUPERPARAMAGNETIC IRON-OXIDE [J].
HAMM, B ;
STAKS, T ;
TAPUITZ, M ;
MAIBAUER, R ;
SPEIDEL, A ;
HUPPERTZ, A ;
FRENZEL, T ;
LAWACZECK, R ;
WOLF, KJ ;
LANGE, L .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05) :659-668