Freestanding chemiresistive polymer composite ribbons as high-flux sensors

被引:10
作者
Benz, Marcel [1 ]
Patel, Sanjay V. [1 ]
机构
[1] Seacoast Sci Inc, Carlsbad, CA 92011 USA
关键词
composites; conducting polymers; fibers; sensors; CHEMICAPACITIVE MICROSENSORS; CARBON; ARRAYS; TEXTILES; NETWORK; DESIGN; AGENT;
D O I
10.1002/app.36538
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Chemiresistive polymer composite ribbons that function as chemical detectors were produced from solution-cast films of polymers and carbon composites. An array with multiple polymer sensor threads was exposed to dimethyl methyl phosphonate, a nerve agent simulant, and different interferents in the vapor phase. Principal component analysis was used to differentiate between the analytes. The response of the ribbon sensors as a function of the carbon composite and the host polymer source was investigated. The freestanding threads/sensors were mounted into a cell perpendicular to the gas flow to provide little pressure drop and were imbedded into fabrics to provide an example of a small, low-cost, wearable chemical sensor. (C) 2012 Wiley Periodicals, Inc. J Appl Polym Sci, 2012
引用
收藏
页码:3986 / 3995
页数:10
相关论文
共 38 条
[1]   Cross-reactive chemical sensor arrays [J].
Albert, KJ ;
Lewis, NS ;
Schauer, CL ;
Sotzing, GA ;
Stitzel, SE ;
Vaid, TP ;
Walt, DR .
CHEMICAL REVIEWS, 2000, 100 (07) :2595-2626
[2]  
[Anonymous], 2009, MODEL TERMS WE UNPUB
[3]  
Barton A.F. M., 1983, CRC HDB SOLUBILITY P
[4]  
Buckley L. J., 1997, U. S. Pat., Patent No. [5,674,752, 5674752]
[5]   Vapor recognition with an integrated array of polymer-coated flexural plate wave sensors [J].
Cai, QY ;
Park, J ;
Heldsinger, D ;
Hsieh, MD ;
Zellers, ET .
SENSORS AND ACTUATORS B-CHEMICAL, 2000, 62 (02) :121-130
[6]   Integrating wireless ECG monitoring in textiles [J].
Coosemans, Johan ;
Hermans, Bart ;
Puers, Robert .
SENSORS AND ACTUATORS A-PHYSICAL, 2006, 130 (48-53) :48-53
[7]  
Dean J. A., 1992, Lange's Handbook of Chemistry
[8]   Application of the solubility parameter concept to the design of chemiresistor arrays [J].
Eastman, MP ;
Hughes, RC ;
Yelton, G ;
Ricco, AJ ;
Patel, SV ;
Jenkins, MW .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1999, 146 (10) :3907-3913
[9]   Evolution of electrical properties of some conductive polymer composite textiles with organic solvent vapours diffusion [J].
Feller, JF ;
Grohens, Y .
SENSORS AND ACTUATORS B-CHEMICAL, 2004, 97 (2-3) :231-242
[10]   Robust fabrication of selective and reversible polymer coated carbon nanotube-based gas sensors [J].
Field, Christopher R. ;
Yeom, Junghoon ;
Salehi-Khojin, Amin ;
Masel, Richard I. .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 148 (01) :315-322