Improvement of T1 Contrast in Whole-brain Black-blood Imaging using Motion-sensitized Driven-equilibrium Prepared 3D Turbo Spin Echo (3D MSDE-TSE)

被引:15
作者
Yoneyama, Masami [1 ]
Nakamura, Masanobu [1 ]
Takahara, Taro [2 ]
Takemura, Atsushi
Obara, Makoto
Tabuchi, Takashi [1 ]
Tatsuno, Satoshi [1 ]
Sawano, Seishi [1 ]
机构
[1] Yaesu Clin, Chuo Ku, Tokyo 1030027, Japan
[2] Tokai Univ, Sch Engn, Dept Biomed Engn, Hiratsuka, Kanagawa 25912, Japan
关键词
anti-driven-equilibrium; black-blood imaging; contrast-enhanced MRI; T-1-contrast; motion-sensitized driven equilibrium; METASTASIS;
D O I
10.2463/mrms.2013-0047
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We demonstrated a new scheme for performing the T-1-enhanced whole-brain black-blood imaging pulse sequence using motion-sensitized driven-equilibrium prepared 3-dimensional (3D) turbo spin echo (MSDE-TSE) with anti-driven-equilibrium post pulse. The use of an anti-driven-equilibrium pulse considerably improved the T-1 contrast of MSDE-TSE blackblood images. This sequence can be used for whole-brain 3D volumetric T-1-weighted blackblood imaging and may improve the accuracy of anatomical localization for certain brain lesions.
引用
收藏
页码:61 / 65
页数:5
相关论文
共 12 条
[1]   Hyperechoes [J].
Hennig, J ;
Scheffler, K .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :6-12
[2]   Detection of brain metastasis at 3T: comparison among SE, IR-FSE and 3D-GRE sequences [J].
Kakeda, Shingo ;
Korogi, Yukunori ;
Hiai, Yasuhiro ;
Ohnari, Norihiro ;
Moriya, Junji ;
Kamada, Koji ;
Hanamiya, Mai ;
Sato, Toru ;
Kitajima, Mika .
EUROPEAN RADIOLOGY, 2007, 17 (09) :2345-2351
[3]  
Komada Tomohiro, 2008, Magn Reson Med Sci, V7, P13, DOI 10.2463/mrms.7.13
[4]   3D Turbo Spin-Echo Sequence with Motion-Sensitized Driven-Equilibrium Preparation for Detection of Brain Metastases on 3T MR Imaging [J].
Nagao, E. ;
Yoshiura, T. ;
Hiwatashi, A. ;
Obara, M. ;
Yamashita, K. ;
Kamano, H. ;
Takayama, Y. ;
Kobayashi, K. ;
Honda, H. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (04) :664-670
[5]   Contrast-Enhanced, Three-Dimensional, Whole-Brain, Black-Blood Imaging: Application to Small Brain Metastases [J].
Park, Jaeseok ;
Kim, Eung Yeop .
MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (03) :553-561
[6]   Diagnostic accuracy of MRI compared to CCT in patients with brain metastases [J].
Schellinger, PD ;
Meinck, HM ;
Thron, A .
JOURNAL OF NEURO-ONCOLOGY, 1999, 44 (03) :275-281
[7]   DRIVEN-EQUILIBRIUM RADIOFREQUENCY PULSES IN NMR IMAGING [J].
VANUIJEN, CMJ ;
DENBOEF, JH .
MAGNETIC RESONANCE IN MEDICINE, 1984, 1 (04) :502-507
[8]  
Visser F, 2011, P ISMRM MONTR, P4242
[9]   Improved suppression of plaque-mimicking artifacts in black-blood carotid atherosclerosis imaging using a multislice motion-sensitized driven-equilibrium (MSDE) turbo spin-echo (TSE) sequence [J].
Wang, Jinnan ;
Yarnykh, Vasily L. ;
Hatsukami, Thomas ;
Chu, Baocheng ;
Balu, Niranjan ;
Yuan, Chun .
MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (05) :973-981
[10]   Enhanced Image Quality in Black-Blood MRI Using the Improved Motion-Sensitized Driven-Equilibrium (iMSDE) Sequence [J].
Wang, Jinnan ;
Yarnykh, Vasily L. ;
Yuan, Chun .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (05) :1256-1263