Patient-specific instrumentation development in TKA: 1st and 2nd generation designs in comparison with conventional instrumentation

被引:26
作者
Kwon, Oh-Ryong [1 ]
Kang, Kyoung-Tak [2 ]
Son, Juhyun [2 ]
Suh, Dong-Suk [1 ]
Heo, Dong Beom [1 ]
Koh, Yong-Gon [1 ]
机构
[1] Yonsei Sarang Hosp, Dept Orthopaed Surg, Joint Reconstruct Ctr, 10 Hyoryeong Ro, Seoul 06698, South Korea
[2] Yonsei Univ, Dept Mech Engn, 50 Yonsei Ro, Seoul 03722, South Korea
关键词
Design improvement; Patient-specific instrument; Total knee arthroplasty; TOTAL KNEE ARTHROPLASTY; ALIGNMENT; REPLACEMENT; NAVIGATION; COMPONENT; SURGERY; GUIDES; MRI; METAANALYSIS; ACCURACY;
D O I
10.1007/s00402-016-2618-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study was conducted to determine if the difference in magnetic resonance imaging (MRI)-based 2nd generation patient-specific instrumentation (PSI) design affects post-operative restoration of neutral mechanical alignment in total knee arthroplasty (TKA) compared with the 1st generation PSI design and conventional surgical techniques. In addition, it is aimed at elucidating whether PSI improves surgical efficiency with respect to operating room time, estimated blood loss and the number of instrument trays used intra-operatively. We report our experience in TKA using PSI techniques in 234 patients from August 2012 to March 2015. The patients were divided into 1st (n = 64) and 2nd (n = 70) generation PSI design. The control group (n = 100) underwent TKA with the conventional instrument technique. The mean surgical time was significantly shorter in the 2nd generation PSI design (62.1 +/- 12.1 min) than in the control group (80.6 +/- 21.7 min; P < 0.001). A mechanical axis malalignment of > 3A degrees of the lower limb was observed in 5.7% of the patients in 2nd generation PSI design compared with 26.0% of the control group (P = 0.006). No significant difference in mechanical alignment on post-operative long alignment radiography was found between 20.3% of the patients in 1st generation PSI design and the control group (P = 0.584). The 1st generation PSI design did not have a shorter surgical time or improved alignment compared with conventional instrumentation (CI). However, the use of the perfectly fitted 2nd generation PSI design was associated with improvements in both of these measurements. This study emphasizes the importance of PSI design in intra-operative and post-operative outcomes of TKA.
引用
收藏
页码:111 / 118
页数:8
相关论文
共 36 条
[1]   Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA [J].
Anderl, Werner ;
Pauzenberger, Leo ;
Koeblinger, Roman ;
Kiesselbach, Gabriele ;
Brandl, Georg ;
Laky, Brenda ;
Kriegleder, Bernhard ;
Heuberer, Philipp ;
Schwameis, Eva .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (01) :102-111
[2]   Comparison of MRI- and CT-based patient-specific guides for total knee arthroplasty [J].
Asada, Shigeki ;
Mori, Shigeshi ;
Matsushita, Tetsunao ;
Nakagawa, Koichi ;
Tsukamoto, Ichiroh ;
Akagi, Masao .
KNEE, 2014, 21 (06) :1238-1243
[3]   Malrotation causing patellofemoral complications after total knee arthroplasty [J].
Berger, RA ;
Crossett, LS ;
Jacobs, JJ ;
Rubash, HE .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (356) :144-153
[4]   Computer-Assisted Techniques Versus Conventional Guides for Component Alignment in Total Knee Arthroplasty [J].
Blakeney, William G. ;
Khan, Riaz J. K. ;
Wall, Simon J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (15) :1377-1384
[5]  
Boni T, 1996, Ther Umsch, V53, P716
[6]   Rapid prototyping: The future of trauma surgery? [J].
Brown, GA ;
Firoozbakhsh, K ;
DeCoster, TA ;
Reyna, JR ;
Moneim, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A :49-55
[7]   Blood loss in total hip arthroplasty for rapidly destructive coxarthrosis [J].
Charrois, O ;
Kahwaji, A ;
Vastel, L ;
Rosencher, N ;
Courpied, JP .
INTERNATIONAL ORTHOPAEDICS, 2001, 25 (01) :22-24
[8]   Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty [J].
Dutton, Andrew Quoc ;
Yeo, Seng-Jin ;
Yang, Kuang-Ying ;
Lo, Ngai-Nung ;
Chia, Kui-Un ;
Chong, Hwei-Chi .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (01) :2-9
[9]   Computer-assisted total knee arthroplasty using patient-specific templating [J].
Hafez, M. A. ;
Chelule, K. L. ;
Seedhom, B. B. ;
Sherman, K. P. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (444) :184-192
[10]   Patient-Specific Instrumentation Does Not Shorten Surgical Time: A Prospective, Randomized Trial [J].
Hamilton, William G. ;
Parks, Nancy L. ;
Saxena, Arjun .
JOURNAL OF ARTHROPLASTY, 2013, 28 (08) :96-100