Comparison of the Accuracy of Newer Intraocular Lens Power Calculation Methods in Eyes That Underwent Previous Phototherapeutic Keratectomy

被引:3
作者
Yagi-Yaguchi, Yukari [1 ]
Negishi, Kazuno [1 ]
Saiki, Megumi [1 ]
Torii, Hidemasa [1 ]
Tsubota, Kazuo [1 ]
机构
[1] Keio Univ, Sch Med, Dept Ophthalmol, Tokyo, Japan
关键词
CATARACT-SURGERY; REFRACTIVE SURGERY; FORMULA;
D O I
10.3928/1081597X-20190410-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the accuracy of intraocular tens (IOL) power calculations using ray tracing software in patients who had undergone phototherapeutic keratectomy (PTK). METHODS: In this retrospective case series, 37 eyes of 22 patients (mean age: 69.4 years; range: 56 to 85 years) who underwent cataract surgery after PTK were reviewed. The prediction error, defined as the difference between the estimated postoperative spherical equivalent and the postoperative manifest refraction at the spectacle plane, was calculated using the following formulas: OKULIX (Tedics, Dortmund, Germany), PhacoOptics (IOL Innovations ApS, Aarhus, Denmark), Barrett True K No History (NH), and Camettin-Catossi. The PhacoOptics formula was used in three different ways: historical method (H), no history method (NH), and C-constant method (CI. The median values of the arithmetic and absolute prediction errors among these six IOL calculation methods were compared. RESULTS: The median arithmetic errors (in diopters and percentages of eyes within +/- 0.50 D of the absolute errors were as follows: OKULIX (0.33, range: -2.20 to 2.50, 30.6%), PhacoOptics (H) (-0.12, range: -3.28 to 4.85, 22.2%), PhacoOptics (NH) (-0.25, range: -2.08 to 1.70, 48.4%), PhacoOptics (C) (0.04, range: -1.40 to 2.18, 48.5%), Barrett True K (NH) (-0.35, range: -1.90 to 1.89, 48.6%), and Camettin-Catossi (-0.19, range: -1.78 to 1.47, 59.5%). CONCLUSIONS: The PhacoOptics, especially the C-constant method (C), and Camellin-Calossi formulas were good options for calculating IOL powers in eyes that underwent PTK.
引用
收藏
页码:310 / +
页数:8
相关论文
共 27 条
[1]   Accuracy of the Barrett True-K formula for intraocular lens power prediction after laser in situ keratomileusis or photorefractive keratectomy for myopia [J].
Abulafia, Adi ;
Hill, Warren E. ;
Koch, Douglas D. ;
Wang, Li ;
Barrett, Graham D. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (03) :363-369
[2]   Intraocular lens power calculation after corneal refractive surgery: Double-K method [J].
Aramberri, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (11) :2063-2068
[4]   A new formula for intraocular lens power calculation after refractive corneal surgery [J].
Camellin, M ;
Calossi, A .
JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (02) :187-199
[5]  
Camellin M, 1990, Refract Corneal Surg, V6, P261
[6]   Refractive changes after excimer laser phototherapeutic keratectomy [J].
Dogru, M ;
Katakami, C ;
Yamanaka, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (05) :686-692
[7]   Comparison of OKULIX ray-tracing software with SRK-T and Hoffer-Q formula in intraocular lens power calculation [J].
Ghoreyshi, Mohammad ;
Khalilian, Ahmadreza ;
Peyman, Mohammadreza ;
Mohammadinia, Mohaddeseh ;
Peyman, Alireza .
JOURNAL OF CURRENT OPHTHALMOLOGY, 2018, 30 (01) :63-67
[8]   Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula [J].
Haigis, Wolfgang .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (10) :1658-1663
[9]  
HOLLAND EJ, 1992, OPHTHALMOLOGY, V99, P1564
[10]   Trial for new intraocular lens power calculation following phototherapeutic keratectomy [J].
Ishikawa, T ;
Hirano, A ;
Inoue, J ;
Nakayasu, K ;
Kanai, A ;
Takeuchi, K ;
Kanda, T .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 2000, 44 (04) :400-406