EM Reconstruction of Dual Isotope PET with Staggered Injections and Prompt Gamma Positron Emitters

被引:0
|
作者
Andreyev, Andriy [1 ]
Sitek, Arkadiusz [2 ]
Celler, Anna [1 ]
机构
[1] Univ British Columbia, Med Imaging Res Grp, Vancouver, BC V5Z 1M9, Canada
[2] Brigham & Womens Hosp, Harvard Med Sch, Dept Radiol, Boston, MA 02115 USA
来源
2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC) | 2012年
关键词
FEASIBILITY; F-18-FDG; HYPOXIA; CANCER;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The aim of Dual Isotope Positron Emission Tomography (DIPET) is to create two independent images of two co-injected radiotracers. DIPET shortens the duration of the study, reduces patient discomfort and produces perfectly co-registered images. Its implementation is difficult because positron decay of any isotope creates only 511 keV photons. Recently, we have proposed a DIPET technique that uses a combination of radiotracer A which is a pure positron emitter (such as F-18 or C-11) and radiotracer B in which positron decay is followed by the emission of a high-energy (HE) prompt gamma (such as K-38 or Cu-60). Events that are detected as triple coincidences of HE gammas with the corresponding two 511 keV photons identify the line-of-responses (LORs) that originate from isotope B (similar to 10% of all events). These LORs are used to separate the two intertwined distributions, using a dedicated image reconstruction algorithm based on Expectation Maximization (EM). However, this approach is suboptimal as it combines high-statistics data (radiotracers A and B), with low-statistics (radiotracer B) to create separate images of radiotracers A and B. We hypothesize that from the performance of DIPET could be improved if an independent estimate of radiotracer A distribution is available by using staggered injections method. Here we investigate this hypothesis by developing and testing an EM-based algorithm for image reconstruction of such data. Our algorithm is general, i.e. can reconstruct staggered data, positron and HE gamma data or a combination of both. Reconstruction of DIPET data obtained from Monte-Carlo simulations shows that the combined method provides the best results in terms of separation of images corresponding to radiotracers A and B. Our EM algorithm provides not only good image separation for the combined method but also when only staggered injections or only prompt gamma data are used.
引用
收藏
页码:3701 / 3706
页数:6
相关论文
共 30 条
  • [1] EM reconstruction of dual isotope PET using staggered injections and prompt gamma positron emitters
    Andreyev, Andriy
    Sitek, Arkadiusz
    Celler, Anna
    MEDICAL PHYSICS, 2014, 41 (02)
  • [2] Dual-isotope PET using positron-gamma emitters
    Andreyev, A.
    Celler, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (14): : 4539 - 4556
  • [3] Quantitative PET with positron emitters that emit prompt gamma rays
    Martin, CC
    Christian, BT
    Satter, MR
    Nickerson, LDH
    Nickles, RJ
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1995, 14 (04) : 681 - 687
  • [4] ML-EM based dual tracer PET image reconstruction with inclusion of prompt gamma attenuation
    Pfaehler, Elisabeth
    Niekaemper, Debora
    Scheins, Juergen
    Shah, N. Jon
    Lerche, Christoph W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2025, 70 (01):
  • [5] Reconstruction of Dual Isotope PET Using Expectation Maximization (EM) Algorithm
    Sitek, Arkadiusz
    Andreyev, Andriy
    Celler, Anna
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4323 - 4326
  • [6] Production of positron-gamma emitters for multiplexed PET (mPET) imaging
    Herraiz, J. L.
    Lage, E.
    Parot, V.
    Dave, S. R.
    Udias, J. M.
    Vaquero, J. J.
    Munoz-Martin, A.
    Fraile, L. M.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [7] A newly designed pinhole collimator for small animal SPECT in dual-isotope study of positron and gamma emitters.
    Kubo, N
    Nishijima, K
    Zhao, S
    Katoh, C
    Motomura, N
    Kuge, Y
    Tsukamoto, E
    Tamaki, N
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 161P - 161P
  • [8] Lesion detectability for hot spot imaging of positron emitters of dedicated PET and positron coincidence gamma camera
    Zhang, H
    Inoue, T
    Ichikawa, A
    Oriuchi, N
    Alyafei, SA
    Endo, K
    RADIOLOGY, 2000, 217 : 113 - 113
  • [9] Image reconstruction method for dual-isotope positron emission tomography
    Fukuchi, T.
    Shigeta, M.
    Haba, H.
    Mori, D.
    Yokokita, T.
    Komori, Y.
    Yamamoto, S.
    Watanabe, Y.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (01)
  • [10] Application of quantum entanglement induced polarization for dual-positron and prompt gamma imaging
    Romanchek, Gregory
    Shoop, Greyson
    Abbaszadeh, Shiva
    BIO-ALGORITHMS AND MED-SYSTEMS, 2023, 19 (01) : 9 - 16