Patient Comfort During Positron Emission Tomography/Magnetic Resonance and Positron Emission Tomography/Computed Tomography Examinations Subjective Assessments With Visual Analog Scales

被引:20
作者
Gueckel, Brigitte [1 ]
Gatidis, Sergios [1 ]
Enck, Paul [2 ]
Schaefer, Juergen [1 ]
Bisdas, Sotirios [3 ]
Pfannenberg, Christina [1 ]
Schwenzer, Nina [1 ]
机构
[1] Univ Dept Radiol, Diagnost & Intervent Radiol, D-72076 Tubingen, Germany
[2] Univ Tubingen Hosp, Dept Internal Med Psychosomat Med 6, Tubingen, Germany
[3] Univ Dept Radiol, Neuroradiol, D-72076 Tubingen, Germany
基金
英国医学研究理事会;
关键词
PET; MR compliance; safety; sensory side effects; subjective perception; visual analog scale; questionnaire; PAIN INTENSITY; INTERNATIONAL WORKSHOP; 7; T; PET/MR; PERFORMANCE; MRI; ACCEPTANCE; TUBINGEN; MR/PET;
D O I
10.1097/RLI.0000000000000177
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The aims of this study were to investigate subjective perceptions and sensory side effects during whole-body positron emission tomography (PET)/magnetic resonance (MR) examinations and to evaluate differences between PET/MR and standard PET/computed tomography (CT) examinations. Material and Methods During prospective clinical trials using a PET/MR hybrid system after a standard PET/CT examination, 266 patients (including 19 juveniles) were asked to complete questionnaires on causes of discomfort and side effects after both examinations (self-assessment). In case of complaints regarding causes of discomfort, physicians were also asked to complete the questionnaires to provide an external assessment. Visual analog scales were used for the ratings. Results Seventy-four percent (183/247) of all adult patients and 68% (13/19) of all teenage patients completed the questionnaires. In most of the cases, patient compliance was good and allowed for the acquisition of diagnostic images. Most patients did not report side effects or discomfort at all. Only 11 of 247 PET/MR scans of adult patients (4.4%) and 4 of 19 scans of juvenile patients (21%) were aborted prematurely by the patients' requests; however, this did not influence the final PET/MR diagnoses in most cases (12/15). In terms of noise levels and examination times, patients rated the PET/MR significantly lower than the PET/CT. With the exception of male patients not tolerating the examination time as well as female patients, no significant influences of sex, age, body mass index, and real scan times were observed. The attending physicians tended to underestimate their patient's discomfort, particularly when the discomfort was because of time (in the case of children) or noise exposure (all patients). Conclusions Patient comfort should drive the design and development of optimized scanner types, workflow processes, and scan protocols. For PET/MR, the most important aim should be to shorten the scan time. However, patient-centered management may be the best instrument to improve patient compliance.
引用
收藏
页码:726 / 732
页数:7
相关论文
共 23 条
[1]   Reduction of Patient Anxiety in PET/CT Imaging by Improving Communication Between Patient and Technologist [J].
Acuff, Shelley N. ;
Bradley, Yong C. ;
Barlow, Patrick ;
Osborne, Dustin R. .
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2014, 42 (03) :211-217
[2]   Qualitative and Quantitative Comparison of PET/CT and PET/MR Imaging in Clinical Practice [J].
Al-Nabhani, Khalsa Z. ;
Syed, Rizwan ;
Michopoulou, Sofia ;
Alkalbani, Jokha ;
Afaq, Asim ;
Panagiotidis, Emmanouil ;
O'Meara, Celia ;
Groves, Ashley ;
Ell, Peter ;
Bomanji, Jamshed .
JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (01) :88-94
[3]   Combined PET/MR: Where Are We Now? Summary Report of the Second International Workshop on PET/MR Imaging April 8-12, 2013, Tubingen, Germany [J].
Bailey, Dale L. ;
Barthel, Henryk ;
Beuthin-Baumann, Bettina ;
Beyer, Thomas ;
Bisdas, Sotirios ;
Boellaard, Ronald ;
Czernin, Johannes ;
Drzezga, Alexander ;
Ernemann, Ulrike ;
Franzius, Christiane ;
Gueckel, Brigitte ;
Handgretinger, Rupert ;
Hartenbach, Markus ;
Hellwig, Dirk ;
Nadel, Helen ;
Nekolla, Stephan G. ;
Pfluger, Thomas ;
Pichler, Bernd J. ;
Quick, Harald H. ;
Sabri, Osama ;
Sattler, Bernhard ;
Schaefer, Jurgen ;
Schick, Fritz ;
Siegel, Barry A. ;
Schlemmer, Heinz P. ;
Schwenzer, Nina F. ;
van den Hoff, Joerg ;
Veit-Haibach, Patrick ;
Wehrl, Hans F. .
MOLECULAR IMAGING AND BIOLOGY, 2014, 16 (03) :295-310
[4]   Summary Report of the First International Workshop on PET/MR Imaging, March 19-23, 2012, Tubingen, Germany [J].
Bailey, Dale L. ;
Barthel, Henryk ;
Beyer, Thomas ;
Boellaard, Ronald ;
Gueckel, Brigitte ;
Hellwig, Dirk ;
Herzog, Hans ;
Pichler, Bernd J. ;
Quick, Harald H. ;
Sabri, Osama ;
Scheffler, Klaus ;
Schlemmer, Heinz P. ;
Schwenzer, Nina F. ;
Wehrl, Hans F. .
MOLECULAR IMAGING AND BIOLOGY, 2013, 15 (04) :361-371
[5]   Short-term side-effects of brain MR examination at 7 T: a single-centre experience [J].
Cosottini, M. ;
Frosini, D. ;
Biagi, L. ;
Pesaresi, I. ;
Costagli, M. ;
Tiberi, G. ;
Symms, M. ;
Tosetti, M. .
EUROPEAN RADIOLOGY, 2014, 24 (08) :1923-1928
[6]  
Delso G, 2011, J NUCL MED, V52, P1914, DOI 10.2967/jnumed.111.092726
[7]   First Clinical Experience with Integrated Whole-Body PET/MR: Comparison to PET/CT in Patients with Oncologic Diagnoses [J].
Drzezga, Alexander ;
Souvatzoglou, Michael ;
Eiber, Matthias ;
Beer, Ambros J. ;
Fuerst, Sebastian ;
Martinez-Moeller, Axel ;
Nekolla, Stephan G. ;
Ziegler, Sibylle ;
Ganter, Carl ;
Rummeny, Ernst J. ;
Schwaiger, Markus .
JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (06) :845-855
[8]   Performance of Whole-Body Integrated 18F-FDG PET/MR in Comparison to PET/CT for Evaluation of Malignant Bone Lesions [J].
Eiber, Matthias ;
Takei, Toshiki ;
Souvatzoglou, Michael ;
Mayerhoefer, Marius E. ;
Fuerst, Sebastian ;
Gaertner, Florian C. ;
Loeffelbein, Denys J. ;
Rummeny, Ernst J. ;
Ziegler, Sibylle I. ;
Schwaiger, Markus ;
Beer, Ambros J. .
JOURNAL OF NUCLEAR MEDICINE, 2014, 55 (02) :191-197
[9]   Validity of four pain intensity rating scales [J].
Ferreira-Valente, Maria Alexandra ;
Pais-Ribeiro, Jose Luis ;
Jensen, Mark P. .
PAIN, 2011, 152 (10) :2399-2404
[10]   A Large-Scale Study on Subjective Perception of Discomfort During 7 and 1.5 T MRI Examinations [J].
Heilmaier, Christina ;
Theysohn, Jens M. ;
Maderwald, Stefan ;
Kraff, Oliver ;
Ladd, Mark E. ;
Ladd, Susanne C. .
BIOELECTROMAGNETICS, 2011, 32 (08) :610-619