Evaluating Component Migration: Comparing Two Generations of the INBONE® Total Ankle Replacement

被引:3
|
作者
Brigido, Stephen A. [1 ]
Wobst, Garrett M. [2 ]
Galli, Melissa M. [3 ]
Protzman, Nicole M. [4 ]
机构
[1] Coordinated Hlth, Foot & Ankle Reconstruct, Foot & Ankle Dept, Bethlehem, PA USA
[2] Avera Orthoped Surg Specialists, Aberdeen, SD USA
[3] CORE Inst, Phoenix, AZ USA
[4] Coordinated Hlth, Clin Educ & Res Dept, Allentown, PA USA
关键词
ankle joint surgery; joint prosthesis; osteoarthritis; subsidence; total ankle replacement; FOLLOW-UP; PERIOPERATIVE COMPLICATIONS; HINTEGRA ANKLE; SHORT-TERM; ARTHROPLASTY;
D O I
10.1053/j.jfas.2015.03.004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Although total ankle replacement (TAR) designs have radically evolved, the compressive forces at the ankle can cause aseptic loosening, talar subsidence, and implant failure. The purpose of the present report was to compare the implant migration associated with the INBONE (R) I, a TAR system with a stemmed talar component, and the newer generation INBONE (R) II, a TAR system without a stemmed talar component (Wright Medical Technology, Inc., Arlington, TN). Because core decompression could weaken the integrity of the talus, we hypothesized that the stemmed component would result in greater implant migration. A total of 35 consecutive patients (age 58.2 +/- 12.1 years; 23 men) were included. Of these 35 patients, 20 (57.1%) had been treated with the INBONE (R) I and 15 (42.9%) with the INBONE (R) II. To assess implant migration, using anteroposterior radiographs, the distance from the apex of the tibial component to the most distal aspect of the talar stem or to the mid-saddle of the nonstemmed component was measured. The measurements were recorded from the immediate postoperative radiographs and the 12-month postoperative radiographs. Implant migration was quantified as the difference between the 12-month and the immediate postoperative measurements. Despite our hypothesis, no significant difference was found in implant migration between the INBONE (R) I (0.7 +/- 1.2 mm) and INBONE (R) II (0.6 +/- 1.3 mm, p = .981). However, previously published data have suggested that implant migration can continue for >= 2 years after surgery. Therefore, additional investigations with larger sample sizes and longer follow-up periods are needed to draw definitive conclusions. (C) 2015 by the American College of Foot and Ankle Surgeons. All rights reserved.
引用
收藏
页码:892 / 895
页数:4
相关论文
共 50 条
  • [11] Insert Position in Three-Component Total Ankle Replacement
    Barg, Alexej
    Elsner, Andreas
    Chuckpaiwong, Bavornrit
    Hintermann, Beat
    FOOT & ANKLE INTERNATIONAL, 2010, 31 (09) : 754 - 759
  • [12] Syndesmotic Overload in 3-Component Total Ankle Replacement
    Ruiz, Roxa
    Susdorf, Roman
    Kraehenbuehl, Nicola
    Barg, Alexej
    Hintermann, Beat
    FOOT & ANKLE INTERNATIONAL, 2020, 41 (03) : 275 - 285
  • [13] Comparison of Treatment Outcomes of Arthrodesis and Two Generations of Ankle Replacement Implants
    Benich, Marisa R.
    Ledoux, William R.
    Orendurff, Michael S.
    Shofer, Jane B.
    Hansen, Sigvard T.
    Davitt, James
    Anderson, John G.
    Bohay, Donald
    Coetzee, J. Chris
    Maskill, John
    Brage, Michael
    Houghton, Michael
    Sangeorzan, Bruce J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (21) : 1792 - 1800
  • [14] Reliability of the Phi angle to assess rotational alignment of the talar component in total ankle replacement
    Manzi, Luigi
    Villafane, Jorge Hugo
    Indino, Cristian
    Tamini, Jacopo
    Berjano, Pedro
    Usuelli, Federico Giuseppe
    FOOT AND ANKLE SURGERY, 2019, 25 (02) : 169 - 173
  • [15] Poor accuracy of plain radiographic measurements of prosthetic migration and alignment in total ankle replacement
    Braito, Matthias
    Liebensteiner, Michael
    Dammerer, Dietmar
    Krismer, Martin
    Pfurner, Martin
    Biedermann, Rainer
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2015, 10
  • [16] Total Replacement of Varus Ankle Three-Component Prosthesis Design
    Hintermann, Beat
    Ruiz, Roxa
    FOOT AND ANKLE CLINICS, 2019, 24 (02) : 305 - +
  • [17] Total Ankle Replacement-Three-Component Prosthesis
    Valderrabano, Victor
    Pagenstert, Geert
    Hintermann, Beat
    TECHNIQUES IN FOOT AND ANKLE SURGERY, 2005, 4 (01): : 42 - 54
  • [18] Tibial Component Subsidence in a Total Ankle System Comparing Standard Technique Versus a Hybrid Technique
    Miner, Samantha A.
    Basile, Philip
    Cook, Jeremy
    Cook, Emily
    Constantino, John
    JOURNAL OF FOOT & ANKLE SURGERY, 2023, 62 (03) : 472 - 478
  • [19] Total ankle replacement with INBONE-II prosthesis: A short-to- medium-term follow-up study in China
    Wu, Yong
    Yang, Hanyuan
    Guo, Xiangbin
    Du, Hui
    Gong, Xiaofeng
    CHINESE MEDICAL JOURNAL, 2022, 135 (12) : 1459 - 1465
  • [20] Total ankle replacement with INBONE-II prosthesis: A short-to-medium-term follow-up study in China
    Wu Yong
    Yang Hanyuan
    Guo Xiangbin
    Du Hui
    Gong Xiaofeng
    中华医学杂志英文版, 2022, 135 (12) : 1459 - 1465