Identification of bone marrow edema of the knee: diagnostic accuracy of dual-energy CT in comparison with MRI

被引:28
作者
Foti, Giovanni [1 ]
Mantovani, William [2 ]
Faccioli, Niccolo [3 ]
Crivellari, Giacomo [3 ]
Romano, Luigi [1 ]
Zorzi, Claudio [4 ]
Carbognin, Giovanni [1 ]
机构
[1] IRCCS Sacro Cuore Don Calabria Hosp, Dept Radiol, Via Don A Sempreboni 10, I-37024 Negrar, VR, Italy
[2] Publ Hlth Trust, Dept Prevent Med, Trento, Italy
[3] Verona Univ Hosp, Dept Radiol, Verona, Italy
[4] IRCCS Sacro Cuore Don Calabria Hosp, Dept Orthoped Surg, Negrar, Italy
来源
RADIOLOGIA MEDICA | 2021年 / 126卷 / 03期
关键词
Knee joint; Magnetic resonance imaging; Computed tomography; Bone marrow; Sensitivity; LESIONS; REDUCTION;
D O I
10.1007/s11547-020-01267-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background To assess the diagnostic accuracy of dual-energy computed tomography (DECT) in diagnosing bone marrow edema (BME) of the knee in traumatic and non-traumatic patients. Methods This prospective IRB approved study included 33 consecutive patients (20 males, 13 females; mean age of 52.2 years) evaluated with DECT (80 and 150 kV) and MRI within 6 days. Two experienced radiologists qualitatively and quantitatively evaluated DECT images. The accuracy values were calculated by using receiver operator curves (ROC) and area under the curve (AUC), using MRI as the reference standard. Inter-observer and intra-observer agreement were calculated withk-statistics. Ap < 0.05 was considered statistically significant. Results MRI depicted BME in 25/33 patients (75.7%). The sensitivity, specificity, PPV, NPV, and accuracy of per-partition qualitative analysis were 92.9, 92.9, 78.2, 97.9, and 92.9%, for reader 1, and 88.2, 93.9, 79.8, 96.6, and 92.6%, for reader 2, respectively. The inter-observer agreement was substantial (k = 0.793) and the intra-observer agreement was near-perfect (k = 0.844). At the quantitative analysis, a significant difference (p < 0.001) was depicted between the density values of positive (mean 3.6 +/- 25.3 HU) and negative cases (mean - 72.2 +/- 45.1 HU). By using - 15 HU cutoff to identify BME, sensitivity, specificity, PPV, NPV, and accuracy of DECT were 84.7, 93.6, 78.2, 95.7, and 91.6%, respectively. Conclusion DECT can accurately identify BME of the knee.
引用
收藏
页码:405 / 413
页数:9
相关论文
共 28 条
[1]   Use of dual-energy CT and virtual non-calcium techniques to evaluate post-traumatic bone bruises in knees in the subacute setting [J].
Ai, Songtao ;
Qu, Mingliang ;
Glazebrook, Katrina N. ;
Liu, Yu ;
Rhee, Peter C. ;
Leng, Shuai ;
McCollough, Cynthia H. .
SKELETAL RADIOLOGY, 2014, 43 (09) :1289-1295
[2]   Transient bone marrow edema syndrome of the knee:: Clinical and magnetic resonance imaging results at 5 years after core decompression [J].
Berger, Christian E. ;
Kroener, Andreas H. ;
Kristen, Karl-Heinz ;
Grabmeier, Georg F. ;
Kluger, Rainer ;
Minai-Pour, Michael B. ;
Leitha, Thomas ;
Engel, Alfred .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2006, 22 (08) :866-871
[3]   Association between traumatic bone marrow abnormalities of the knee, the trauma mechanism and associated soft-tissue knee injuries [J].
Berger, Nicole ;
Andreisek, Gustav ;
Karer, Anissja T. ;
Bouaicha, Samy ;
Naraghi, Ali ;
Manoliu, Andrei ;
Seifert, Burkhardt ;
Ulbrich, Erika J. .
EUROPEAN RADIOLOGY, 2017, 27 (01) :393-403
[4]  
Berkem L, 2013, ACTA ORTHOP BELG, V79, P572
[5]   Diagnostic accuracy of dual-energy CT for detection of bone marrow lesions in the subacutely injured knee with MRI as reference method [J].
Bjorkman, Ann-Sofi ;
Koskinen, Seppo K. ;
Lindblom, Maria ;
Persson, Anders .
ACTA RADIOLOGICA, 2020, 61 (06) :749-759
[6]   Follow-up of occult bone lesions detected at MR imaging: Systematic review [J].
Boks, SS ;
Vroegindeweij, D ;
Koes, BW ;
Hunink, MGM ;
Bierma-Zeinstra, SMA .
RADIOLOGY, 2006, 238 (03) :853-862
[7]   Color-coded virtual non-calcium dual-energy CT for the depiction of bone marrow edema in patients with acute knee trauma: a multireader diagnostic accuracy study [J].
Booz, Christian ;
Noeske, Jochen ;
Lenga, Lukas ;
Martin, Simon S. ;
Yel, Ibrahim ;
Eichler, Katrin ;
Gruber-Rouh, Tatjana ;
Huizinga, Nicole ;
Albrecht, Moritz H. ;
Vogl, Thomas J. ;
Wichmann, Julian L. .
EUROPEAN RADIOLOGY, 2020, 30 (01) :141-150
[8]   Good interrater reliability of a new grading system in detecting traumatic bone marrow lesions in the knee by dual energy CT virtual non-calcium images [J].
Cao, Jian-xin ;
Wang, Yi-min ;
Kong, Xiang-quan ;
Yang, Cheng ;
Wang, Peng .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (06) :1109-1115
[9]   AAOS Appropriate Use Criteria: Management of Osteochondritis Dissecans of the Femoral Condyle [J].
Carey, James L. ;
Shea, Kevin G. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2016, 24 (09) :E105-E111
[10]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .