Salicylaldehyde functionalized chitosan for electrochemical sensitive sensor: Simultaneous determination of catechol and hydroquinone

被引:16
|
作者
Deng, Peihong [1 ]
Zhou, Chuanqin [2 ]
Wei, Yanping [2 ]
Yue, Xuan [1 ]
Li, Junhua [1 ]
Yao, Liangyuan [3 ]
Ding, Jianhua [4 ]
He, Quanguo [2 ,3 ,4 ]
机构
[1] Hengyang Normal Univ, Dept Chem & Mat Sci, Key Lab Organometall New Mat, Coll Hunan Prov,Key Lab Funct Met Organ Cpds Huna, Hengyang 421008, Peoples R China
[2] Hunan Univ Technol, Sch Life Sci & Chem, Zhuzhou 412007, Peoples R China
[3] Hunan Qianjin Xiangjiang Pharmaceut Joint Stock C, Zhuzhou 412001, Peoples R China
[4] Zhuzhou Peoples Hosp, Zhuzhou 421007, Peoples R China
关键词
Salicylaldehyde functionalized chitosan; Hydroquinone; Catechol; Simultaneous determination; Voltammetry; GLASSY-CARBON ELECTRODE; PHENOLIC-COMPOUNDS; WATER; OXIDE;
D O I
10.1016/j.jelechem.2022.116506
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Salicylaldehyde functionalized chitosan (S-CHIT) was prepared and electrochemical sensor based on the above material and acetylene black paste electrode (ABPE) were constructed. A new method for the simultaneous detection of catechol (CC) and hydroquinone (HQ) was established. The results of Fourier transform infrared spectroscopy (FT-IR) and scanning electron microscopy (SEM) showed that S-CHIT had been successfully synthesized and attached to the surface of ABPE. Cyclic voltammetry (CV) and second-order derivative linear sweep voltammetry (SDLSV) were used to investigate the electrochemical behaviors of CC and HQ on the S-CHIT/ABPE. In 0.1 M H2SO4 solution, CC and HQ produced a pair of reversible redox peaks with good shape on the modified electrode. The quantitative determination of CC and HQ was performed by SDLSV using the oxidation signal. The difference of the oxidation peak potentials between CC and HQ was 112 mV. In the presence of 50 mu M of the respective isomer, the linear concentration range of CC and HQ is 0.6 mu M to 80 mu M and 1.0 mu M to 80 mu M respectively, and the corresponding detection limits are 0.1 mu M and 0.4 mu M. The method was applied to the simultaneous determination of CC and HQ in water samples. The results show that S-CHIT/ABPE is a promising electrochemical sensor for the simultaneous detection of CC and HQ.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] A Novel Sensitive Electrochemical Sensor for the Simultaneous Determination of Hydroquinone and Catechol using Tryptophan-Functionalized Graphene
    Jiang, Huan
    Zhang, Dongxia
    He, Zhifang
    Lian, Qianwen
    Xue, Zhonghua
    Zhou, Xibin
    Lu, Xiaoquan
    ANALYTICAL LETTERS, 2015, 48 (09) : 1426 - 1436
  • [2] An electrochemical sensor based on the three-dimensional functionalized graphene for simultaneous determination of hydroquinone and catechol
    Du, Jie
    Ma, Linlin
    Shan, Duoliang
    Fan, Yanru
    Zhang, Liping
    Wang, Li
    Lu, Xiaoquan
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 722 : 38 - 45
  • [3] Disposable graphite paper based sensor for sensitive simultaneous determination of hydroquinone and catechol
    Fan, Limei
    Li, Xueyan
    Kan, Xianwen
    ELECTROCHIMICA ACTA, 2016, 213 : 504 - 511
  • [4] Influence of micelles on the electrochemical behaviors of catechol and hydroquinone and their simultaneous determination
    Juan Peng
    Zuo-Ning Gao
    Analytical and Bioanalytical Chemistry, 2006, 384 : 1525 - 1532
  • [5] Influence of micelles on the electrochemical behaviors of catechol and hydroquinone and their simultaneous determination
    Peng, J
    Gao, ZN
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (7-8) : 1525 - 1532
  • [6] A Sensitive Electrochemical Sensor Based on Dual Co-Doped N, P-rGO for Simultaneous Determination of Hydroquinone and Catechol
    Liu, Yanyan
    Xie, Ruirui
    Zou, Xun
    Liu, Jiamin
    Wu, Zhiyong
    Peng, Chang
    Zhao, Peng
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (01)
  • [7] An electrochemical sensor based on titanium oxide–carbon nanotubes nanocomposite for simultaneous determination of hydroquinone and catechol
    Zuchao Meng
    Hongfang Zhang
    Jianbin Zheng
    Research on Chemical Intermediates, 2015, 41 : 3135 - 3146
  • [8] Electrochemical fabrication of reusable pencil graphite electrodes for highly sensitive, selective and simultaneous determination of hydroquinone and catechol
    Nagarajan, Sedhu
    Vairamuthu, Raj
    Angamuthu, Raja
    Venkatachalam, Ganesh
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 846
  • [9] Electrochemical preparation of activated graphene oxide for the simultaneous determination of hydroquinone and catechol
    Velmurugan, Murugan
    Karikalan, Natarajan
    Chen, Shen-Ming
    Cheng, Yi-Hui
    Karuppiah, Chelladurai
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2017, 500 : 54 - 62
  • [10] An electrochemical sensor based on titanium oxide-carbon nanotubes nanocomposite for simultaneous determination of hydroquinone and catechol
    Meng, Zuchao
    Zhang, Hongfang
    Zheng, Jianbin
    RESEARCH ON CHEMICAL INTERMEDIATES, 2015, 41 (05) : 3135 - 3146