Development of a Novel Automated Hair Counting System for the Quantitative Evaluation of Laser Hair Removal

被引:2
作者
Lim, Hyoung-woo [1 ]
Cho, Minwoo [1 ]
Lee, Dong-Hun [2 ]
Koh, Wooseok [3 ]
Kim, Youdan [4 ]
Chung, Jin Ho [2 ]
Kim, Sungwan [5 ,6 ]
机构
[1] Seoul Natl Univ, Coll Engn, Interdisciplinary Program Bioengn, Seoul, South Korea
[2] Seoul Natl Univ, Inst Human Environm Interface Biol, Dept Dermatol, Coll Med, Seoul, South Korea
[3] JMO Dermatol, Seoul, South Korea
[4] Seoul Natl Univ, Inst Adv Aerosp Technol, Dept Mech & Aerosp Engn, Coll Engn, Seoul, South Korea
[5] Seoul Natl Univ, Dept Biomed Engn, Coll Med, 101 Daehak Ro, Seoul 110799, South Korea
[6] Seoul Natl Univ, Inst Med & Biol Engn, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
dermatology; imaging/imaging science; laser irradiation; low-power; photomedicine; PULSED ALEXANDRITE LASER; CUBIC CONVOLUTION INTERPOLATION; MODE RUBY-LASER; GROWTH IN-VIVO; SELECTIVE PHOTOTHERMOLYSIS; TRICHOSCAN; TOOL;
D O I
10.1089/pho.2016.4140
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: We aimed to develop and validate a novel computer-assisted automated hair counting system for the quantitative evaluation of laser hair removal (LHR). Methods: We developed a computer-aided image processing system to count hairs on shaved skin and validated its performance through clinical trials. Five volunteers of Fitzpatrick skin type III-IV volunteered and were tested on both thighs. The system automatically detects hair and places a "+" sign on each hair site for every positive detection. This method allows clinicians to check whether a hair has been counted or not. We analyzed the difference in the hair counts between the proposed system (automatic) and those by human observers (manual). Results: The hair counts from the proposed system and the manual counts were compared. The percentage error between automatic and manual counting was <5% in each subject. The data of the two groups were statistically verified with Student's independent t-test. The averages were statistically equivalent between the two groups. The proposed system showed significant time saving in terms of counting. Conclusions: A dependable, accurate, and fast method of counting hairs on shaved skin through a computer-aided image processing system was developed and validated. The "+" signs on the image to indicate detection allows clinicians to compare with the original image and detect any omission or redundancy. The proposed system is expected to be reliable in analyzing the results of multiple skin-related treatments, including LHR and hair transplantation. Further, it is expected to be widely applicable for use in the clinic.
引用
收藏
页码:116 / 121
页数:6
相关论文
共 29 条
[1]   Extended theory of selective photothermolysis [J].
Altshuler, GB ;
Anderson, RR ;
Manstein, D ;
Zenzie, HH ;
Smirnov, MZ .
LASERS IN SURGERY AND MEDICINE, 2001, 29 (05) :416-432
[2]   SELECTIVE PHOTOTHERMOLYSIS - PRECISE MICROSURGERY BY SELECTIVE ABSORPTION OF PULSED RADIATION [J].
ANDERSON, RR ;
PARRISH, JA .
SCIENCE, 1983, 220 (4596) :524-527
[3]   Hair removal using a long-pulsed alexandrite laser [J].
Ash, K ;
Lord, J ;
Newman, J ;
McDaniel, DH .
DERMATOLOGIC CLINICS, 1999, 17 (02) :387-+
[4]  
Cosmetic Surgery National Data Bank Statistics, 2014, COSM SURG NAT DAT BA, P27
[5]   Permanent hair removal by normal-mode ruby laser [J].
Dierickx, CC ;
Grossman, MC ;
Farinelli, WA ;
Anderson, RR .
ARCHIVES OF DERMATOLOGY, 1998, 134 (07) :837-842
[6]   Laser hair removal with alexandrite versus diode laser using four treatment sessions: 1-year results [J].
Eremia, S ;
Li, C ;
Newman, N .
DERMATOLOGIC SURGERY, 2001, 27 (11) :925-930
[7]   Laser Hair Removal: A Review [J].
Gan, Stephanie D. ;
Graber, Emmy M. .
DERMATOLOGIC SURGERY, 2013, 39 (06) :823-838
[8]   Damage to hair follicles by normal-mode ruby laser pulses [J].
Grossman, MC ;
Dierickx, C ;
Farinelli, W ;
Flotte, T ;
Anderson, RR .
JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 1996, 35 (06) :889-894
[9]  
Hoffman R, 2001, EUR J DERMATOL, V11, P362